Personalized Anatomic Eye Model From T1-Weighted Volume Interpolated Gradient Echo Magnetic Resonance Imaging of Patients With Uveal Melanoma

被引:13
|
作者
Nguyen, Huu-Giao [1 ,2 ,3 ,4 ]
Sznitman, Raphael [2 ]
Maeder, Philippe [3 ]
Schalenbourg, Ann [6 ]
Peroni, Marta [1 ]
Hrbacek, Jan [1 ]
Weber, Damien C. [1 ]
Pica, Alessia [1 ]
Cuadra, Meritxell Bach [3 ,4 ,5 ]
机构
[1] Paul Scherrer Inst, ETH Domain, Proton Therapy Ctr, Villigen, Switzerland
[2] Univ Bern, ARTORG Ctr, Ophthalm Technol Lab, Bern, Switzerland
[3] Lausanne Univ Hosp, Radiol Dept, Lausanne, Switzerland
[4] Univ Lausanne, Ctr Imagerie BioMed, Med Image Anal Lab, Lausanne, Switzerland
[5] Ecole Polytech Fed Lausanne, Signal Proc Lab, Lausanne, Switzerland
[6] Univ Lausanne, Adult Ocular Oncol Unit, Jules Gonin Eye Hosp, FAA,Dept Ophthalmol, Lausanne, Switzerland
关键词
PROTON-BEAM RADIOTHERAPY; THIN-SECTION MR; AUTOMATIC SEGMENTATION; SPACE;
D O I
10.1016/j.ijrobp.2018.05.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We present a 3-dimensional patient-specific eye model from magnetic resonance imaging (MRI) for proton therapy treatment planning of uveal melanoma (UM). During MRI acquisition of UM patients, the point fixation can be difficult and, together with physiological blinking, can introduce motion artifacts in the images, thus challenging the model creation. Furthermore, the unclear boundary of the small objects (eg, lens, optic nerve) near the muscle or of the tumors with hemorrhage and tantalum clips can limit model accuracy. Methods and Materials: A dataset of 37 subjects, including 30 healthy eyes of volunteers and 7 eyes of UM patients, was investigated. In our previous work, active shape model was successfully applied to retinoblastoma eye segmentation in T1-weighted 3T MRI. Here, we evaluate this method in a more challenging setting, based on 1.5T MRI acquisition and different datasets of awake adult eyes with UM. The lens and cornea together with the sclera, vitreous humor, and optic nerve were automatically segmented and validated against manual delineations of a senior ocular radiation oncologist, in terms of the Dice similarity coefficient and Hausdorff distance. Results: Leave-one-out cross validation (mixing both volunteers and UM patients) yielded median Dice similarity coefficient values (respective of Hausdorff distance) of 94.5% (1.64 mm) for the sclera, 92.2% (1.73 mm) for the vitreous humor, 88.3% (1.09 mm) for the lens, and 81.9% (1.86 mm) for the optic nerve. The average computation time for an eye was 10 seconds. Conclusions: To our knowledge, our work is the first attempt to automatically segment adult eyes, including patients with UM. Our results show that automated active shape model segmentation can succeed in the presence of motion, tumors, and tantalum clips. These results are promising for inclusion in clinical practice. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:813 / 820
页数:8
相关论文
共 50 条
  • [21] Hypointense lesions on T1-weighted spin-echo magnetic resonance imaging -: Relation to clinical characteristics in subgroups of patients with multiple sclerosis
    van Walderveen, MAA
    Lycklama à Nijeholt, GJ
    Adèr, HJ
    Jongen, PJH
    Polman, CH
    Castelijns, JA
    Barkhof, F
    ARCHIVES OF NEUROLOGY, 2001, 58 (01) : 76 - 81
  • [22] Qualitative and Quantitative Analysis of a Spiral Gradient Echo Sequence for Contrast-Enhanced Fat-Suppressed T1-Weighted Spine Magnetic Resonance Imaging
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    van Smoorenburg, Luuk
    Sartoretti-Schefer, Sabine
    Wyss, Michael
    Binkert, Christoph A.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (08) : 517 - 524
  • [23] Hypointensities in the Brain on T2*-Weighted Gradient-Echo Magnetic Resonance Imaging
    Tsushima, Yoshito
    Endo, Keigo
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2006, 35 (04) : 140 - 150
  • [24] Evaluation of Fetal Thyroid with 3D Gradient Echo T1-weighted MR Imaging
    Fujii, Shinya
    Nagaishi, Junichi
    Mukuda, Naoko
    Kaneda, Sachi
    Inoue, Chie
    Fukunaga, Takeru
    Ogawa, Toshihide
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 203 - 208
  • [25] Fat-Suppressed 3D T1-Weighted Gradient-Echo Imaging of the Cartilage With a Volumetric Interpolated Breath-Hold Examination
    Zheng, Zhuo-Zhao
    Shan, Han
    Li, Xuan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : W414 - W419
  • [26] Diagnosis of symptomatic disc by magnetic resonance imaging: T2-weighted and gadolinium-DTPA-enhanced T1-weighted magnetic resonance imaging
    Yoshida, H
    Fujiwara, A
    Tamai, K
    Kobayashi, N
    Saiki, K
    Saotome, K
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (03): : 193 - 198
  • [27] Additional value of magnetic resonance with spin echo T1-weighted imaging with fat suppression in characterization of soft tissue tumors
    Gielen, JLMA
    De Schepper, AMA
    Parizel, PM
    Wang, XL
    Vanhoenacker, F
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 434 - 441
  • [28] T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques
    Narumi, Shinsuke
    Sasaki, Makoto
    Miyazawa, Haruna
    Natori, Tatsunori
    Ito, Kohei
    Ogasawara, Kuniaki
    Kobayashi, Masakazu
    Hitomi, Jiro
    Terayama, Yasuo
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (02): : 273 - 279
  • [29] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Yoon, Jeong Hee
    Lee, Jeong Min
    Lee, Eun Sun
    Baek, Jeehyun
    Lee, Sangwoo
    Iwadate, Yuji
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (02): : 278 - 288
  • [30] Small hepatocellular carcinoma: assessment with T1-weighted spin-echo magnetic resonance imaging with and without fat suppression
    Koushima, Y
    Ebara, M
    Fukuda, H
    Morimoto, N
    Sugiura, N
    Yoshikawa, M
    Sanada, M
    Saisho, H
    Matsumoto, T
    Yukawa, M
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 41 (01) : 34 - 41