Simulation Studies of a Phoswich PET Detector Design with a Two-Fold Improvement in Spatial Sampling

被引:0
|
作者
Zhang, Xuezhu [1 ]
Thompson, Christopher J. [1 ]
Thiessen, Jonathan D. [1 ]
Goertzen, Andrew L. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
基金
加拿大自然科学与工程研究理事会;
关键词
IMAGE-RECONSTRUCTION; PERFORMANCE; BLOCKS; INSERT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phoswich detector designs, which combine multiple scintillator materials each having unique light emission properties, have been extensively studied for improving spatial sampling in PET. In this work we propose a detector for PET imaging based on a 2D scintillator array in which each scintillator element in the array is a phoswich pair consisting of two scintillator materials (with different emission decay times) optically coupled together so that scintillation light can freely pass between the two halves of the phoswich pair. A conventional reflector is placed between the scintillator elements. When an NxN crystal array of this design is imaged with a conventional detector (i.e. no decay time discrimination) it will appear to be simply an NxN array, however when the decay time discrimination is enabled, the left/right half of each element can be identified and the sampling becomes 2NxN. In this way, a detector can have spatial sampling of X/2xY while only needing to resolve crystal elements of size XxY. This design can readily be extended to multi-layer detectors, in particular dual-layer offset (DLO) designs. The potential improvement in spatial resolution achieved by a DLO detector using this phoswich design was studied using an analytical simulation and fully 3D LOR based reconstruction with system response modeling for a 16 detector small animal PET system with inner ring diameter of 60 mm and a 1.6 mm crystal pitch (0.8x1.6 mm phoswich sub-element size). Four versions of the DLO design were simulated, corresponding to the 4 possible combinations of the top and bottom crystal layer alignments (i.e. parallel and perpendicular to the axial direction). In each case a 20% event misidentification in the phoswich pair was simulated. The best spatial resolution was obtained for the case of both top and bottom layer phoswich elements having their long side aligned with the axial direction, giving the best transaxial sampling. For this case, 0.7 mm hot rods were well resolved.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Two-Fold Sampling-Based Super-Resolution Estimation of Low-Rank MIMO-OFDM Channels
    Liu, Tianle
    Fahad Masood, Khawaja
    Tong, Jun
    He, Jiguang
    Jiangtao Xi, And
    [J]. IEEE Open Journal of the Communications Society, 2024, 5 : 7434 - 7446
  • [32] Design and simulation of a positron detector to measure the AIF for dynamic PET.
    Carroll, Liam
    Enger, Shirin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [33] Spatial variation of the two-fold anisotropic superconducting gap in a monolayer of FeSe0.5Te0.5 on a topological insulator
    Kamlapure, A.
    Manna, S.
    Cornils, L.
    Haenke, T.
    Bremholm, M.
    Hofmann, Ph.
    Wiebe, J.
    Wiesendanger, R.
    [J]. PHYSICAL REVIEW B, 2017, 95 (10)
  • [34] Design and Performance of a High Spatial Resolution, Time-of-Flight PET Detector
    Krishnamoorthy, Srilalan
    LeGeyt, Benjamin
    Werner, Matthew E.
    Kaul, Madhuri
    Newcomer, F. M.
    Karp, Joel S.
    Surti, Suleman
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1092 - 1098
  • [35] An overview of spatial sampling procedures and experimental design of spatial studies for ecosystem comparisons
    Stein, A
    Ettema, C
    [J]. AGRICULTURE ECOSYSTEMS & ENVIRONMENT, 2003, 94 (01) : 31 - 47
  • [36] Design studies of a high resolution PET detector using APD arrays
    Shao, Y
    Silverman, RW
    Farrell, R
    Cirignano, L
    Grazioso, R
    Shah, KS
    Visser, G
    Clajus, M
    Tümer, TO
    Cherry, SR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1051 - 1057
  • [38] Investigation of spatial resolution improvement by use of a mouth-insert detector in the helmet PET scanner
    Ahmed A.M.
    Tashima H.
    Yamaya T.
    [J]. Radiological Physics and Technology, 2018, 11 (1) : 7 - 12
  • [39] High-resolution PET detector design: modelling components of intrinsic spatial resolution
    Stickel, JR
    Cherry, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02): : 179 - 195
  • [40] Timing performance of two PET detector designs capable of time-of-flight and depth-of-interaction measurement: phoswich and offset crystal layers
    Chang, Chen-Ming
    Levin, Craig S.
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,