Simulation Studies of a Phoswich PET Detector Design with a Two-Fold Improvement in Spatial Sampling

被引:0
|
作者
Zhang, Xuezhu [1 ]
Thompson, Christopher J. [1 ]
Thiessen, Jonathan D. [1 ]
Goertzen, Andrew L. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
基金
加拿大自然科学与工程研究理事会;
关键词
IMAGE-RECONSTRUCTION; PERFORMANCE; BLOCKS; INSERT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phoswich detector designs, which combine multiple scintillator materials each having unique light emission properties, have been extensively studied for improving spatial sampling in PET. In this work we propose a detector for PET imaging based on a 2D scintillator array in which each scintillator element in the array is a phoswich pair consisting of two scintillator materials (with different emission decay times) optically coupled together so that scintillation light can freely pass between the two halves of the phoswich pair. A conventional reflector is placed between the scintillator elements. When an NxN crystal array of this design is imaged with a conventional detector (i.e. no decay time discrimination) it will appear to be simply an NxN array, however when the decay time discrimination is enabled, the left/right half of each element can be identified and the sampling becomes 2NxN. In this way, a detector can have spatial sampling of X/2xY while only needing to resolve crystal elements of size XxY. This design can readily be extended to multi-layer detectors, in particular dual-layer offset (DLO) designs. The potential improvement in spatial resolution achieved by a DLO detector using this phoswich design was studied using an analytical simulation and fully 3D LOR based reconstruction with system response modeling for a 16 detector small animal PET system with inner ring diameter of 60 mm and a 1.6 mm crystal pitch (0.8x1.6 mm phoswich sub-element size). Four versions of the DLO design were simulated, corresponding to the 4 possible combinations of the top and bottom crystal layer alignments (i.e. parallel and perpendicular to the axial direction). In each case a 20% event misidentification in the phoswich pair was simulated. The best spatial resolution was obtained for the case of both top and bottom layer phoswich elements having their long side aligned with the axial direction, giving the best transaxial sampling. For this case, 0.7 mm hot rods were well resolved.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Preliminary Studies of J-PET Detector Spatial Resolution
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Alfs, D.
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kisielewska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krawczyk, N.
    Krzemien, W.
    Kubicz, E.
    Mohammed, M.
    Palka, M.
    Raczynski, L.
    Raj, J.
    Rudy, Z.
    Shivani
    Silarski, M.
    Skurzok, M.
    Sharma, N. G.
    Sharma, S.
    Shopa, R. Y.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    [J]. ACTA PHYSICA POLONICA A, 2017, 132 (05) : 1645 - 1648
  • [22] Optical simulation study on the spatial resolution of a thick monolithic PET detector
    Stockhoff, Mariele
    Van Holen, Roel
    Vandenberghe, Stefaan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [23] Computer simulation for design of depth encoding multicrystal detector for PET
    Haneishi, H
    Nishiya, S
    Miyake, Y
    Murayama, H
    Omura, T
    Ishibashi, H
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1207 - 1211
  • [24] 2-D TWO-FOLD SYMMETRIC CIRCULAR SHAPED FILTER DESIGN WITH HOMOMORPHIC PROCESSING APPLICATION
    Seneviratne, A. J.
    Kha, H. H.
    Tuan, H. D.
    Nguyen, T. Q.
    [J]. 2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 3694 - 3697
  • [25] Importance sampling-based algorithms for efficiently estimating failure chance index under two-fold random uncertainty
    Li, Fen
    Lu, Zhenzhou
    Feng, Kaixuan
    Jiang, Xia
    [J]. STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2022, 65 (07)
  • [26] Importance sampling-based algorithms for efficiently estimating failure chance index under two-fold random uncertainty
    Fen Li
    Zhenzhou Lu
    Kaixuan Feng
    Xia Jiang
    [J]. Structural and Multidisciplinary Optimization, 2022, 65
  • [27] Design and Evaluation of LYSO/SiPM LIGHTENING PET Detector with DTI Sampling Method
    Deng, Zhenzhou
    Deng, Yushan
    Chen, Guandong
    [J]. SENSORS, 2020, 20 (20) : 1 - 18
  • [28] Artificial intelligence-based PET denoising could allow a two-fold reduction in [18F]FDG PET acquisition time in digital PET/CT
    Kathleen Weyts
    Charline Lasnon
    Renaud Ciappuccini
    Justine Lequesne
    Aurélien Corroyer-Dulmont
    Elske Quak
    Bénédicte Clarisse
    Laurent Roussel
    Stéphane Bardet
    Cyril Jaudet
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 3750 - 3760
  • [29] Artificial intelligence-based PET denoising could allow a two-fold reduction in [18F]FDG PET acquisition time in digital PET/CT
    Weyts, Kathleen
    Lasnon, Charline
    Ciappuccini, Renaud
    Lequesne, Justine
    Corroyer-Dulmont, Aurelien
    Quak, Elske
    Clarisse, Benedicte
    Roussel, Laurent
    Bardet, Stephane
    Jaudet, Cyril
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (11) : 3750 - 3760
  • [30] High-resolution PET detector with 100 ps coincidence time resolution using side-by-side phoswich design
    Lee, Min Sun
    Cates, Joshua W.
    Levin, Craig S.
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,