Design studies of a high resolution PET detector using APD arrays

被引:86
|
作者
Shao, Y [1 ]
Silverman, RW
Farrell, R
Cirignano, L
Grazioso, R
Shah, KS
Visser, G
Clajus, M
Tümer, TO
Cherry, SR
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Mol & Med Pharmacol, Crump Inst Biol Imaging, Los Angeles, CA 90024 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02172 USA
[3] NOVA R&D Inc, Riverside, CA USA
关键词
D O I
10.1109/23.856546
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We evaluated a compact, high resolution PET detector module using avalanche photodiode (APD) arrays to replace bulky position sensitive PMTs. The newly developed APD array is a planar processed 4x4 array which has a 2x2 mm(2) pixel size with 0.4 mm gaps between pixels, about 60% quantum efficiency at 420 nm wavelength, and uniform high gain (> 1000) across all channels. A 4x4 array of 2x2x10 mm(3) LSO crystals was coupled to an APD array. Different readout electronics and signal multiplexing schemes were explored. All crystals in the detector array were clearly identified in the flood source histogram, with average peak-to-valley ratios of about 12:1 using a charge sharing resistor network. The energy resolution was measured to be similar to 14% at 511 keV in the detector array. The measured timing resolution was 2.6 ns in coincidence with a LSO/PMT detector. By optimizing the readout electronics currently being used, it is likely that detector performance can be further improved. We have also determined depth-of-interaction (DOI) by reading out two APD arrays connected to the ends of a 2x2x22 mm(3) LSO crystal. Preliminary measurements show good DOI measurement capability with DOT positioning uncertainty between 4 and 6.5 mm.
引用
收藏
页码:1051 / 1057
页数:7
相关论文
共 50 条
  • [2] Planar APD arrays for high resolution PET
    Shah, KS
    Farrell, R
    Cirignano, L
    Grazioso, R
    Bennett, P
    Cherry, SR
    Shao, YP
    [J]. MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 104 - 111
  • [3] A compact high resolution pet detector using an APD array.
    Shao, Y
    Silverman, RW
    Farrell, R
    Cirignano, L
    Grazioso, R
    Shah, KS
    Cherry, SR
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 75P - 75P
  • [4] High Resolution PET Detector Design Using SiPM Array
    Radnia, A.
    Farahani, M.
    Ay, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S450 - S450
  • [5] Design of a high resolution phoswich PET detector
    Wei, Qingyang
    Wang, Shi
    Ma, Tianyu
    Lu, Lingjun
    Dai, Tiantian
    Liu, Yaqiang
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2874 - 2876
  • [6] Electronics design of a PET detector module with APD array
    Wang, Yong-Gang
    [J]. Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2002, 22 (05):
  • [7] A multilayer detector for PET based on APD arrays and continuous crystal elements
    McCallum, S
    Clowes, P
    Welch, A
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2898 - 2902
  • [8] Development of low power high speed readout electronics for high resolution PET with LSO and APD arrays
    Visser, G
    Cherry, S
    Clajus, M
    Shao, YP
    Tümer, TO
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1988 - 1992
  • [9] Spatial resolution and depth-of-interaction studies with a PET detector module composed of LSO and an APD array
    Fremout, AAR
    Chen, RR
    Bruyndonckx, P
    Tavernier, SPK
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 131 - 138
  • [10] Development of a Prototype Detector Using APD-Arrays Coupled With Pixelized Ce:GAGG Scintillator for High Resolution Radiation Imaging
    Kamada, Kei
    Shimazoe, Kenji
    Ito, Shigeki
    Yoshino, Masao
    Endo, Takanori
    Tsutsumi, Kousuke
    Kataoka, Jun
    Kurosawa, Shunsuke
    Yokota, Yuui
    Takahashi, Hiroyuki
    Yoshikawa, Akira
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 348 - 352