摘要
Phoswich technique is used in PET detector development to improve spatial resolution by obtaining the depth of interaction (DOI) information or reduce the number of electronic channels. In this work, a new design scheme is proposed to reduce event's mispositioning in the transverse direction. A 6x6 detector block is assembled with two types of crystals, L YSO and YSO in an interleaved placed pattern in the transverse direction and then couple to four PMTs with quadrant-sharing technique. The block was exposed to a flood source of Cs137. The signals were recorded digitally by an oscilloscope (LeCroy waveRunner 204MXi-A) under the sequence mode. By linearly fitting the waveforms, the decay time constant of the two crystal materials were experimentally determined, which is tau(LYSO) = 44.2.8 +/- 5.8 ns and tau(YSO) = 72.8 +/- 13.2 ns. In the phoswich, a triple-Gaussian model was used to fit the distribution of the decay time constants for considering of the cross-talk. When the cut is set as 56.2 ns, the crystal discrimination rate is between 75.7% and 91.6%. Separated 2-dimension maps (2Dmap) can be generated for each kind of crystal. Compared to the 6x6 2Dmap, the two 3x6 2Dmaps has minimal overlap in the interleave direction. The design is capable of reduce event's mispositioning and improving the spatial resolution of the detector.
引用
收藏
页码:2874 / 2876
页数:3
相关论文
共 50 条
  • [1] High-resolution PET detector with 100 ps coincidence time resolution using side-by-side phoswich design
    Lee, Min Sun
    Cates, Joshua W.
    Levin, Craig S.
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [2] A phoswich detector design for improved spatial sampling in PET
    Thiessen, Jonathan D.
    Koschan, Merry A.
    Melcher, Charles L.
    Meng, Fang
    Schellenberg, Graham
    Goertzen, Andrew L.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 882 : 124 - 128
  • [3] A high performance phoswich detector module for small animal PET.
    Lee, IJ
    Vaquero, JJ
    Barbosa, FJ
    Seidel, J
    Green, MV
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 19P - 20P
  • [4] TraPET: High performance small animal PET with trapezoidal phoswich detector
    Chung, Yong Hyun
    Hwang, Ji Yeon
    Baek, Cheol-Ha
    An, Su Jung
    Kim, Hyun-Il
    Kim, Kwang Hyun
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 802 - 805
  • [5] High Resolution PET Detector Design Using SiPM Array
    Radnia, A.
    Farahani, M.
    Ay, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S450 - S450
  • [6] Design of DOI PET detector modules using phoswich and SiPMs: First Results
    Vaquero, J. J.
    Sanchez, J. J.
    Lage, E.
    Udias, J. M.
    Guerra, P.
    Desco, M.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3311 - 3313
  • [7] Investigation of a scalable phoswich crystal design for a TOF-DOI PET detector
    Chang, Chen-Ming
    Lee, Brian J.
    Sacco, Ilaria
    Levin, Craig S.
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [8] Simulation Study of Side-By-Side Phoswich PET Detector Configuration for Providing High Spatial Resolution of <0.4 mm
    Han, Soo Kyeong
    Yang, Jingyu
    Hong, Sungsoo
    Kang, Jihoon
    [J]. 2018 JOINT 10TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS (SCIS) AND 19TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (ISIS), 2018, : 346 - 349
  • [10] Design studies of a high resolution PET detector using APD arrays
    Shao, Y
    Silverman, RW
    Farrell, R
    Cirignano, L
    Grazioso, R
    Shah, KS
    Visser, G
    Clajus, M
    Tümer, TO
    Cherry, SR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1051 - 1057