Reliability of medial temporal lobe volume measurements using reformatted 3D images

被引:56
|
作者
Bartzokis, G
Altshuler, LL
Greider, T
Curran, J
Keen, B
Dixon, WJ
机构
[1] W Los Angeles Vet Affairs Med Ctr, Res Serv, Los Angeles, CA 90073 USA
[2] Univ Calif Los Angeles, Dept Psychiat, Los Angeles, CA 90074 USA
[3] Univ Calif Los Angeles, Dept Radiol, Los Angeles, CA 90074 USA
[4] Gen Elect Med Syst, Milwaukee, WI 53188 USA
关键词
magnetic resonance imaging; methodology; temporal horn; hippocampus; amygdala;
D O I
10.1016/S0925-4927(98)00007-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The study assessed whether standardizing the angle of image display and controlling for head position in three planes affects the scan-rescan reliability of medial temporal lobe volume measures when very thin (1.5 mm) slices are used. Five volunteers were scanned two times oil consecutive days. A three-dimensional MRI sequence acquired whole brain data in 1.4 mm thick coronal slices. The data were displayed as 1.5 mm thick images and were rated both in the originally acquired coronal plane, and after reformatting to correct for head tilt and display the brain in the coronal plane perpendicular to the long axis of the left anterior hippocampus. One rater measured five brain regions (temporal lobe, anterior and posterior hippocampus, amygdala, and temporal horn) on the left and right sides of the two non-reformatted and two reformatted scans to obtain inter-scan variance. Furthermore, most scans were remeasured, to obtain 'reread' variances. All data were log-transformed in order to produce comparable variability across brain regions of different sizes. For all the regions, except the temporal horn, the non-reformatted scans showed significantly larger scan-rescan variability than the reformatted scans. A typical standard deviation for a non-reformatted pair of scans was 0.10, corresponding to 26% error, while a typical value for a reformatted pair of scans was 0.04, corresponding to 10% error. For all the regions, the reread data (intra-rater reliability) gave similar results for both reformatted and non-reformatted images with similar standard deviations (typical value for reread standard deviation was 0.020, corresponding to 5% error). The data suggest that, even when very thin slices are acquired, volume measurement accuracy of gray matter structures in the temporal lobe is considerably improved by controlling for image orientation in three planes. For these structures, the sample size needed to detect a small (5%) within-subject volume change would be halved if reformatted images were used. Image contrast is an additional important factor since the reformatted T-1 weighted images used in this study, which have suboptimal CSF/brain contrast, worsened measurement accuracy in the temporal horn. (C) 1998 Elsevier Science Ireland Ltd.
引用
收藏
页码:11 / 24
页数:14
相关论文
共 50 条
  • [1] Medial temporal lobe volume measurement reliability using reformatted 3D images
    Bartzokis, G
    Altshuler, L
    Grieder, T
    Curran, J
    BIOLOGICAL PSYCHIATRY, 1997, 41 : 49 - 49
  • [2] Accuracy and reliability of measurements obtained from computed tomography 3D volume rendered images
    Stull, Kyra E.
    Tise, Meredith L.
    Ali, Zabiullah
    Fowler, David R.
    FORENSIC SCIENCE INTERNATIONAL, 2014, 238 : 133 - 140
  • [3] Reliability of 3D MRI cartilage volume measurements.
    Hunter, DJ
    Tay, H
    Peppa, D
    Warfield, S
    ARTHRITIS AND RHEUMATISM, 2002, 46 (09): : S151 - S151
  • [4] 3D MAPPING OF TAU NEUROFIBRILLARY TANGLE PATHOLOGY IN THE HUMAN MEDIAL TEMPORAL LOBE
    Yushkevich, Paul A.
    de Onzono Martin, Maria Mercedes Iniguez
    Ittyerah, Ranjit
    Lim, Sydney
    Lavery, Madigan
    Wang, Jiancong
    Hung, Ling Yu
    Vergnet, Nicolas
    Ravikumar, Sadhana
    Xie, Long
    Done, Mengjin
    DeFlores, Robin
    Cui, Salena
    McCollum, Lauren
    Ohm, Daniel T.
    Robinson, John L.
    Schuck, Theresa
    Grossman, Murray
    Tisdall, M. Dylan
    Prabhakaran, Karthik
    Mizsei, Gabor
    Das, Sandhitsu R.
    Artacho-Perula, Emilio
    Arroyo Jimenez, Maria del Mar
    Munoz Lopez, Monica
    Marcos Rabal, Maria Pilar
    Molina Romero, Francisco Javier
    Lee, Edward B.
    Trojanowski, John Q.
    Wisse, Laura E. M.
    Wolk, David A.
    Irwin, David J.
    Insausti, Ricardo
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1312 - 1316
  • [5] Utility of 3D reformatted images in the diagnosis of sternoclavicular joint injury
    Dennis Heaton
    Yang Wang
    Brittany Moore
    Luke Frager
    Brian M. Everist
    Jamie Crist
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 741 - 745
  • [6] Utility of 3D reformatted images in the diagnosis of sternoclavicular joint injury
    Heaton, Dennis
    Wang, Yang
    Moore, Brittany
    Frager, Luke
    Everist, Brian M.
    Crist, Jamie
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 741 - 745
  • [7] Extracting medial curves on 3D images
    Ma, CM
    Wan, SY
    Chang, HK
    PATTERN RECOGNITION LETTERS, 2002, 23 (08) : 895 - 904
  • [8] Fetal Lung Volume Measurements using 3D Ultrasonography
    Tesanic, D. Miric
    Merz, E.
    Wellek, S.
    ULTRASCHALL IN DER MEDIZIN, 2011, 32 (04): : 373 - 380
  • [9] Images of medial temporal lobe functions in human learning and memory
    Gabrieli, JDE
    Brewer, JB
    Poldrack, RA
    NEUROBIOLOGY OF LEARNING AND MEMORY, 1998, 70 (1-2) : 275 - 283
  • [10] Medial Temporal Lobe Volume Predicts Elders' Everyday Memory
    Bailey, Heather R.
    Zacks, Jeffrey M.
    Hambrick, David Z.
    Zacks, Rose T.
    Head, Denise
    Kurby, Christopher A.
    Sargent, Jesse Q.
    PSYCHOLOGICAL SCIENCE, 2013, 24 (07) : 1113 - 1122