Copper oxide nanoparticles and ionic liquid modified carbon electrode for the non-enzymatic electrochemical sensing of hydrogen peroxide

被引:95
|
作者
Ping, Jianfeng [1 ]
Ru, Shiping [1 ]
Fan, Kai [1 ]
Wu, Jian [1 ]
Ying, Yibin [1 ]
机构
[1] Zhejiang Univ, Coll Biosyst Engn & Food Sci, Hangzhou 310029, Zhejiang, Peoples R China
关键词
Copper oxide nanoparticles; Ionic liquid; Hydrogen peroxide; Carbon ionic liquid electrode; GRAPHITE COMPOSITE ELECTRODES; ELECTROCATALYTIC REDUCTION; AMPEROMETRIC DETECTION; CUO NANOSTRUCTURES; GLUCOSE-OXIDASE; SENSOR; NANOWIRES; BIOSENSOR; FILM; NITRITE;
D O I
10.1007/s00604-010-0420-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The direct electrocatalytic reduction of hydrogen peroxide in alkaline medium at a carbon ionic liquid electrode modified with copper oxide nanoparticles was investigated. The electrode was prepared by mixing graphite particles, ionic liquid (n-octylpyridium hexafluorophosphate) and copper oxide nanoparticles. Unlike the film-modified electrode, the fabrication of this electrode is simple and highly reproducible. The combination of the good conductivity of the ionic liquid and the high catalytic activity of the nanoparticles resulted in an electrode with attractive properties for the determination of hydrogen peroxide. The concentration of NaOH and the loading of copper oxide nanoparticles were optimized. The linear range for the determination of hydrogen peroxide is from 1.0 mu M to 2.5 mM, the detection limit is 0.5 mu M. High stability, sensitivity, selectivity and reproducibility, fast response, the ease of preparation, and surface renewal made the electrode well suitable for the determination of hydrogen peroxide in real samples.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [41] Synthesis of Carbon dots/Layered Double Hydroxide Composites for Non-enzymatic Electrochemical Sensing of Hydrogen Peroxide
    Prabhakaran, Praveena
    Ashok, M.
    [J]. DAE SOLID STATE PHYSICS SYMPOSIUM 2018, 2019, 2115
  • [42] Non-enzymatic sensing of uric acid using a carbon nanotube ionic-liquid paste electrode modified with poly(β-cyclodextrin)
    Yonghong Li
    Xiurong Zhai
    Haibo Wang
    Xinsheng Liu
    Le Guo
    Xiaoling Ji
    Ling Wang
    Hongyan Qiu
    Xiaoying Liu
    [J]. Microchimica Acta, 2015, 182 : 1877 - 1884
  • [43] Non-enzymatic sensing of uric acid using a carbon nanotube ionic-liquid paste electrode modified with poly(β-cyclodextrin)
    Li, Yonghong
    Zhai, Xiurong
    Wang, Haibo
    Liu, Xinsheng
    Guo, Le
    Ji, Xiaoling
    Wang, Ling
    Qiu, Hongyan
    Liu, Xiaoying
    [J]. MICROCHIMICA ACTA, 2015, 182 (11-12) : 1877 - 1884
  • [44] Electrochemical behavior of Azure A/gold nanoclusters modified electrode and its application as non-enzymatic hydrogen peroxide sensor
    Priya, C.
    Sivasankari, G.
    Narayanan, S. Sriman
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2012, 97 : 90 - 96
  • [45] Non-Enzymatic Glucose Sensing Using Carbon Quantum Dots Decorated with Copper Oxide Nanoparticles
    Maaoui, Houcem
    Teodoresu, Florina
    Wang, Qian
    Pan, Guo-Hui
    Addad, Ahmed
    Chtourou, Radhouane
    Szunerits, Sabine
    Boukherroub, Rabah
    [J]. SENSORS, 2016, 16 (10)
  • [46] Electroless deposition of Gold-Platinum Core@Shell Nanoparticles on Glassy Carbon Electrode for Non-Enzymatic Hydrogen Peroxide sensing
    Gowthaman, N. S. K.
    John, S. Abraham
    [J]. JOURNAL OF CHEMICAL SCIENCES, 2016, 128 (03) : 331 - 338
  • [47] A simple non-enzymatic hydrogen peroxide sensor using gold nanoparticles-graphene-chitosan modified electrode
    Jia, Ningming
    Huang, Baozhen
    Chen, Lina
    Tan, Liang
    Yao, Shouzhuo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 165 - 170
  • [48] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    [J]. MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [49] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    [J]. Microchimica Acta, 2012, 176 : 389 - 395
  • [50] Non-enzymatic determination of hydrogen peroxide in milk samples using Graphite oxide/Nafion/Azure A modified electrode
    Priya, Chandrasekaran
    Anuja, Sriraman
    Devendiran, Mani
    Babu, Rajendran Suresh
    Narayanan, Sangilimuthu Sriman
    [J]. IONICS, 2024, 30 (05) : 2869 - 2880