Accurate lithium isotopic analysis of twenty geological reference materials by multi-collector inductively coupled plasma mass spectrometry

被引:19
|
作者
Li, Xiaoqiang [1 ]
Han, Guilin [1 ]
Zhang, Qian [2 ]
Qu, Rui [1 ]
Miao, Zhuang [3 ]
机构
[1] China Univ Geosci Beijing, Inst Earth Sci, Beijing 100083, Peoples R China
[2] Chinese Acad Sci, Inst Geog Sci & Nat Resources Res, Beijing 100101, Peoples R China
[3] China Univ Geosci, Sch Earth Sci & Resources, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Li isotopes; K isotopes; Dual-column; Reference materials; MC-ICP-MS; MC-ICP-MS; LI ISOTOPES; WEATHERING PROCESSES; CONTINENTAL-CRUST; FRACTIONATION; PRECISE; SAMPLES; SEPARATION; BEHAVIOR; ROCK;
D O I
10.1016/j.sab.2021.106348
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The lithium (Li) isotopes can be used to track the evolution of continental silicate weathering, which has an important role in maintaining Earth's long-term climate stability. At present, complex separation procedures and analytical mass bias restrict the accurate determination of Li isotopic compositions in various geological samples with different Li concentrations and matrix/Li ratios. Here, an optimization of dual-column chromatography achieves high Li recovery, low procedural blank, and low Na/Li ratio (< 1) after purification, allowing the acquisition of high precision Li isotope ratios by a Nu Plasma 3 multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). In order to evaluate the accuracy of new method, the 87Li values of BHVO-2, BCR-2, AGV-2, JG-2, RGM-2, SGR-1b, GSR-6, GSR-12, and seawater, are repeatedly analyzed more than 3 times each and are consistent with the published data within the uncertainty. The long-term external reproducibility of 87Li based on L-SVEC and IRMM-016 pure solutions is about +/- 0.2%0 (2SD), and is suitable for analysis of geological samples. These results suggest that new dual-column method is reproducible and reliable. We also report ten new reference materials including two USGS rocks (SDC-1: 1.8 +/- 0.4%0; W-2a: 2.9 +/- 0.3%0), four soils (GSS-3: 1.3 +/- 0.2%0; GSS-4: -5.1 +/- 0.4%0; GSS-6: -1.9 +/- 0.3%0; GSS-8: 0.4 +/- 0.3%0), and four stream sediments (GSD-6: -1.0 +/- 0.4%0; GSD-11: 1.1 +/- 0.3%0; GSD-12: 1.8 +/- 0.2%0; GSD-14: 1.6 +/- 0.4%0), all previously analyzed for K isotopes. There is significantly fractionation of Li and K isotopes during silicate weathering. Compared to the K isotopes, Li isotopes have more promising as an isotope tool for weathering due to its larger fractionation and its abiotic property.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Development of an indigenous multi-collector inductively coupled plasma mass spectrometer
    Yogesh Kumar
    R. K. Bhatia
    E. Ravisankar
    Prakash Abichandani
    T. K. Saha
    V. Nataraju
    R. K. Vatsa
    Indian Journal of Physics, 2024, 98 : 2559 - 2570
  • [22] Isotope Ratio Analysis of Lead in Blood and Environmental Samples by Multi-collector Inductively Coupled Plasma Mass Spectrometry
    Mai Takagi
    Jun Yoshinaga
    Atsushi Tanaka
    Haruhiko Seyama
    Analytical Sciences, 2011, 27 : 29 - 35
  • [23] Development of an indigenous multi-collector inductively coupled plasma mass spectrometer
    Kumar, Y.
    Bhatia, R. K.
    Ravisankar, E.
    Abichandani, Prakash
    Saha, T. K.
    Nataraju, V.
    Vatsa, R. K.
    INDIAN JOURNAL OF PHYSICS, 2024, 98 (07) : 2559 - 2570
  • [24] Improved nickel-corrected isotopic analysis of iron using high-resolution multi-collector inductively coupled plasma mass spectrometry
    Chen, Kai-Yun
    Yuan, Hong-Lin
    Liang, Peng
    Bao, Zhi-An
    Chen, Lu
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 421 : 196 - 203
  • [25] Thorium isotopic measurements on silicate rock samples with a multi-collector inductively coupled plasma mass spectrometer
    Nakai, S
    Fukuda, S
    Nakada, S
    ANALYST, 2001, 126 (10) : 1707 - 1710
  • [26] Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Varga, Z.
    Krachler, M.
    Nicholl, A.
    Ernstberger, M.
    Wiss, T.
    Wallenius, M.
    Mayer, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1076 - 1080
  • [27] Influence of room temperature on magnesium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Zhang, Xing-Chao
    Zhang, An-Yu
    Zhang, Zhao-Feng
    Huang, Fang
    Yu, Hui-Min
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (13) : 1026 - 1030
  • [29] Separation and Precise Measurement of Lithium Isotopes in Three Reference Materials Using Multi Collector-Inductively Coupled Plasma Mass Spectrometry
    Tian Shihong
    Hou Zengqian
    Su Aina
    Hou Kejun
    Hu Wenjie
    Li Zhenzhen
    Zhao Yue
    Gao Yanguang
    Li Yanhe
    Yang Dan
    Yang Zhusen
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2012, 86 (05) : 1297 - 1305
  • [30] Isotope fractionation during ion beam formation in multi-collector inductively coupled plasma mass spectrometry
    Kivel, Niko
    Guenther-Leopold, Ines
    Vanhaecke, Frank
    Guenther, Detlef
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 126 - 132