Evaluation of daylighting performance in an office building: A case study

被引:4
|
作者
Udhwani, Lokesh [1 ]
Soni, Archana [1 ]
机构
[1] Maulana Azad Natl Inst Technol, Bhopal, India
关键词
Materials; Illumination; Dimmers; Topical climate;
D O I
10.1016/j.matpr.2020.09.518
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Lighting load holds a major share of electricity consumed in domestic and office buildings. The available sunlight can effectively reduce these loads during daytime. Illumination of indoor locations using daylight in conjunction with the artificial lighting employing dimming control works best in the domain. Despite a wide range of developed and commercially available daylighting systems have been reported, their applications have been limited by a lack of studies on their utilizations and high initial costs. Computer simulations have been frequently used in the past to investigate daylighting performance due to reliable and accurate predictions. In this article performance of daylighting combined with artificial lighting (with dimming) has been evaluated on the basis of illumination distribution inside a conference hall and annual energy saving. It was observed that 56.3% of energy was saved on annual basis when the simulation was run on a case of Conference hall located at the MANIT, Bhopal. (c) 2020 Elsevier Ltd. All rights reserved. Selection and peer-review under responsibility of the scientific committee of the International Conference on Innovations in Clean Energy Technologies.
引用
收藏
页码:5626 / 5631
页数:6
相关论文
共 50 条
  • [41] The influence of daylighting in buildings with parameters nZEB: application to the case study for an office in Tuscany Mediterranean area
    Carletti, Cristina
    Cellai, Gianfranco
    Pierangioli, Leone
    Sciurpi, Fabio
    Secchi, Simone
    [J]. BEYOND NZEB BUILDINGS, 2017, 140 : 339 - 350
  • [42] PUTTING AN OFFICE BUILDING ON ICE: A CASE STUDY.
    McGarity, A.E.
    Kirkpatrick, D.L.
    Norford, L.K.
    [J]. Construction Specifier, 1987, 40 (06): : 83 - 90
  • [43] Energy efficient design of an office building: A case study
    Anderson, GO
    Grover, HK
    [J]. POWER AND ENERGY SYSTEMS, PROCEEDINGS, 2003, : 191 - 197
  • [44] Energy efficiency and conservation in an office building: a case study
    Hartungi, Rusdy
    Jiang, Liben
    [J]. INTERNATIONAL JOURNAL OF ENERGY SECTOR MANAGEMENT, 2012, 6 (02) : 175 - 188
  • [45] Experimental and simulation study on the performance of daylighting in an industrial building and its energy saving potential
    Chen, Yuanyi
    Liu, Junjie
    Pei, Jingjing
    Cao, Xiaodong
    Chen, Qingyan
    Jiang, Yi
    [J]. ENERGY AND BUILDINGS, 2014, 73 : 184 - 191
  • [46] Evaluation of indoor air quality and its symptoms in office building - A case study of Mashhad, Iran
    Atarodi, Zahra
    Karimyan, Kamaladdin
    Gupta, Vinod Kumar
    Abbasi, Morteza
    Moradi, Masoud
    [J]. DATA IN BRIEF, 2018, 20 : 74 - 79
  • [47] POST OCCUPANCY EVALUATION OF ADAPTIVELY REUSED BUILDINGS: CASE STUDY OF AN OFFICE BUILDING IN SAUDI ARABIA
    Hamida, Mohammad B.
    Hassanain, Muhammad A.
    [J]. ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2020, 13 (01) : 29 - 40
  • [48] A holistic approach to evaluate building performance gap of green office buildings: A case study in China
    Wu, Xiaoying
    Lin, Borong
    Papachristos, George
    Liu, Pei
    Zimmermann, Nici
    [J]. BUILDING AND ENVIRONMENT, 2020, 175
  • [49] Improving illuminance performance by implementing a kinetic facade system: case study of office building in Dubai
    Taleb, Hanan M.
    Moarbes, Rudy
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2023, 22 (05) : 2809 - 2826
  • [50] Building Retrofit to Improve Energy Performance from Office to Accommodation. Case study: Tower Building, Nottingham, UK
    Ardiani, Nissa Aulia
    Suhendri
    Koerniawan, Mochamad Donny
    Budiarto, Rachmawan
    [J]. 2018 3RD INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND MATERIALS SCIENCE (ICCEMS 2018), 2018, 206