Evaluation of indoor air quality and its symptoms in office building - A case study of Mashhad, Iran

被引:11
|
作者
Atarodi, Zahra [1 ]
Karimyan, Kamaladdin [2 ,3 ]
Gupta, Vinod Kumar [4 ]
Abbasi, Morteza [5 ]
Moradi, Masoud [6 ]
机构
[1] Gonabad Univ Med Sci, Students Res Comm, Gonabad, Iran
[2] Kurdistan Univ Med Sci, Environm Hlth Res Ctr, Sanandaj, Iran
[3] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[4] Univ Johannesburg, Dept Appl Chem, Johannesburg, South Africa
[5] Torbat Heydariyeh Univ Med Sci, Behvarz Training Ctr, Torbat Heydariyeh, Iran
[6] Kermanshah Univ Med Sci, Res Ctr Environm Determinants Hlth, Kermanshah, Iran
来源
DATA IN BRIEF | 2018年 / 20卷
关键词
Indoor air quality; Sick building syndrome; Air pollution; Mashhad;
D O I
10.1016/j.dib.2018.07.051
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Air pollution sources in indoor area are one of the main factors for reducing indoor air quality of locations. In the current research, factors affecting indoor air quality and its symptoms are evaluate as case study in an office building in Mashhad (Iran). In order to conduct this descriptive-analytical study, gas pollutants affecting indoor air quality were determined using portable analysis systems. Alberta Indoor Air Quality Toolkit was used in order to study sick building syndrome. Findings indicated that 21% of staffs viewed labor environment conditions as inappropriate and they were mostly compliant about feeling of dusty air, fatigue and headache. In addition, findings showed that O-3, VOC, PM10, PM2.5, CO, CO2 parameters, Formaldehyde, temperature, sound and humidity were at standard level. Indicators of indoor air quality, in addition to the stress and depression interference on employee performance and satisfaction were at acceptable level. (C) 2018 The Authors. Published by Elsevier Inc.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [1] STUDY OF INDOOR AIR QUALITY IN SELECTED OFFICE BUILDING
    Vilcekova, Silvia
    Estokova, Adriana
    Pilipova, Ivana
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [2] INDOOR AIR-QUALITY EVALUATION OF A NEW OFFICE BUILDING
    GROT, RA
    HODGSON, AT
    DAISEY, JM
    PERSILY, A
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1991, 33 (09): : 16 - &
  • [3] Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study
    Ewa Brągoszewska
    Izabela Biedroń
    Barbara Kozielska
    Józef S. Pastuszka
    [J]. Air Quality, Atmosphere & Health, 2018, 11 : 729 - 740
  • [4] Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study
    Bragoszewska, Ewa, I
    Biedron, Izabela
    Kozielska, Barbara
    Pastuszka, Jozef S.
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (06): : 729 - 740
  • [5] Influence of heating systems on indoor air quality and sick building syndrome (a case study in Qom, Iran)
    Salari, Mehdi
    Tabatabaei, Fatemeh Sadat
    Fouladi-Fard, Reza
    Mohammadbeigi, Abolfazl
    Nadali, Azam
    Fahiminia, Mohammad
    Fiore, Maria
    [J]. INTERNATIONAL JOURNAL OF VENTILATION, 2023, 22 (03) : 257 - 272
  • [6] Indoor environmental quality evaluation in a hot and arid climate: a case study of a higher education office building
    Abdou, Yasmin
    Kim, Young Ki
    Bande, Lindita
    [J]. 2020 11TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND DEVELOPMENT (ICESD 2020), 2020, 167
  • [7] Indoor air quality evaluation in intelligent building
    Cociorva, Sorin
    Iftene, Andreea
    [J]. SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT, EENVIRO 2016, 2017, 112 : 261 - 268
  • [8] Monitored Indoor Environmental Quality of a Mass Timber Office Building: A Case Study
    Stenson, Jason
    Ishaq, Suzanne L.
    Laguerre, Aurelie
    Loia, Andrew
    MacCrone, Georgia
    Mugabo, Ignace
    Northcutt, Dale
    Riggio, Mariapaola
    Barbosa, Andre
    Gall, Elliott T.
    Van Den Wymelenberg, Kevin
    [J]. BUILDINGS, 2019, 9 (06)
  • [9] The indoor environmental index and its relationship with symptoms of office building occupants
    Moschandreas, DJ
    Sofuoglu, SC
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (11) : 1440 - 1451
  • [10] THE EFFECTS OF REDUCED VENTILATION ON INDOOR AIR-QUALITY IN AN OFFICE BUILDING
    TURIEL, I
    HOLLOWELL, CD
    MIKSCH, RR
    RUDY, JV
    YOUNG, RA
    COYE, MJ
    [J]. ATMOSPHERIC ENVIRONMENT, 1983, 17 (01) : 51 - 64