Monitored Indoor Environmental Quality of a Mass Timber Office Building: A Case Study

被引:12
|
作者
Stenson, Jason [1 ,2 ]
Ishaq, Suzanne L. [2 ]
Laguerre, Aurelie [3 ]
Loia, Andrew [1 ]
MacCrone, Georgia [2 ]
Mugabo, Ignace [4 ]
Northcutt, Dale [1 ,2 ]
Riggio, Mariapaola [5 ]
Barbosa, Andre [4 ]
Gall, Elliott T. [3 ]
Van Den Wymelenberg, Kevin [1 ,2 ]
机构
[1] Univ Oregon, Dept Architecture, Energy Studies Bldg Lab, Eugene, OR 97403 USA
[2] Univ Oregon, Biol & Built Environm Ctr, Eugene, OR 97403 USA
[3] Portland State Univ, Mech & Mat Engn, Portland, OR 97201 USA
[4] Oregon State Univ, Sch Civil & Construct Engn, Corvallis, OR 97331 USA
[5] Oregon State Univ, Dept Wood Sci & Engn, Corvallis, OR 97331 USA
关键词
mass timber; cross laminated timber; air quality; bacterial community; vibration; VOLATILE ORGANIC-COMPOUNDS; VOC EMISSIONS; AIR-QUALITY; PERFORMANCE; PRODUCTS; EXPOSURE; OZONE; BTEX;
D O I
10.3390/buildings9060142
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A broad range of building performance monitoring, sampling, and evaluation was conducted periodically after construction and spanning more than a year, for an occupied office building constructed using mass timber elements such as cross-laminated timber (CLT) floor and roof panels, as well as glue-laminated timber (GLT) beams and columns. This case study contributes research on monitoring indoor environmental quality in buildings, describing one of the few studies of an occupied mass timber building, and analyzing data in three areas that impact occupant experience: indoor air quality, bacterial community composition, and floor vibration. As a whole, the building was found to perform well. Volatile organic compounds (VOCs), including formaldehyde, were analyzed using multiple methods. Formaldehyde was found to be present in the building, though levels were below most recommended exposure limits. The source of formaldehyde was not able to be identified in this study. The richness of the bacterial community was affected by the height of sampling with respect to the floor, and richness and composition was affected by the location within the building. Floor vibration was observed to be below recognized human comfort thresholds.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Environmental Impact of a Mass Timber Building-A Case Study
    Vanova, Rozalia
    Stompf, Patrik
    Stefko, Jozef
    Stefkova, Jaroslava
    [J]. FORESTS, 2021, 12 (11):
  • [2] Indoor environmental quality evaluation in a hot and arid climate: a case study of a higher education office building
    Abdou, Yasmin
    Kim, Young Ki
    Bande, Lindita
    [J]. 2020 11TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND DEVELOPMENT (ICESD 2020), 2020, 167
  • [3] STUDY OF INDOOR AIR QUALITY IN SELECTED OFFICE BUILDING
    Vilcekova, Silvia
    Estokova, Adriana
    Pilipova, Ivana
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [4] Building toward better breathing: Indoor environmental quality in office construction
    [J]. 2001, Construction Specifications Institute Inc. (54):
  • [5] Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study
    Ewa Brągoszewska
    Izabela Biedroń
    Barbara Kozielska
    Józef S. Pastuszka
    [J]. Air Quality, Atmosphere & Health, 2018, 11 : 729 - 740
  • [6] The effect of ventilation on the indoor environment quality in a natural ventilated office building, a case study
    Avgeilis, A.
    Papadopoulos, A. M.
    [J]. Proceedings of the 8th International Conference on Environmental Science and Technology, Vol A, Oral Presentations, 2003, : 44 - 51
  • [7] Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study
    Bragoszewska, Ewa, I
    Biedron, Izabela
    Kozielska, Barbara
    Pastuszka, Jozef S.
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (06): : 729 - 740
  • [8] Evaluation of indoor air quality and its symptoms in office building - A case study of Mashhad, Iran
    Atarodi, Zahra
    Karimyan, Kamaladdin
    Gupta, Vinod Kumar
    Abbasi, Morteza
    Moradi, Masoud
    [J]. DATA IN BRIEF, 2018, 20 : 74 - 79
  • [9] Efficient design of an office building as Steel/Timber hybrid – A case study
    Anwaar, Omer
    Bello-Garcia, Micael
    de Paula Filho, J.H. Matias
    [J]. ce/papers, 2023, 6 (3-4) : 1037 - 1042
  • [10] An analysis of indoor environmental quality in an office: The case of an university campus in Istanbul
    Sunar, P.
    Tanriover, S.
    [J]. CONTRIBUTIONS TO BUILDING PHYSICS, 2013, : 201 - 207