Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study

被引:0
|
作者
Ewa Brągoszewska
Izabela Biedroń
Barbara Kozielska
Józef S. Pastuszka
机构
[1] Silesian University of Technology,Department of Air Protection
[2] Institute for Ecology of Industrial Areas,Environmental Microbiology Unit
来源
关键词
Bioaerosol; Bacteria; Air conditioning; Occupational exposure; IAQ;
D O I
暂无
中图分类号
学科分类号
摘要
Bioaerosols play a significant role in indoor air quality (IAQ) as they can be the cause of several health problems, including acute allergies and infectious diseases. This study aimed to characterize and compare the microbial air quality of air-conditioned (AC) and naturally ventilated (NV) office rooms in the Upper Silesia region of Poland. The bacterial samples were collected during the late spring season. Culturable bacteria were deposited on the nutrient media on Petri dishes to investigate the viable-culturable count (VCC) of bacteria and bacterial community structure using a Biolog GEN III system. In total, 12 species of bacteria were identified, with the most isolated Macrococcus equipercicus, Micrococcus luteus D, Staphylococcus xylosus (indoor), and Bacillus species (outdoor). The indoor mean concentrations of bacterial aerosol ranged from 102 to 103 CFU m−3, below Polish proposals for threshold limit standards in office buildings. The indoor-to-outdoor (I/O) ratios indicated that studied air pollutants in the office rooms originated from the indoor air. These results, together with community composition of bacteria, indicate that most of the bacteria present in the studied office building were relatively fresh and of human origin. Multi-antibiotic resistance (MAR) tests showed that the most antibiotic-resistant features were present in Macrococcus species. The office building exposure dose (OBED) and mass median aerodynamic diameter (MMAD) of bacteria aerosol were estimated. The highest value of OBED over the study period was obtained for staff working in offices with natural ventilation (141 CFU kg−1), in contrast to the value for staff working in offices equipped with air conditioning (about 100 CFU kg−1). The MMAD of viable airborne bacteria was higher in AC offices (2.4 μm) than in NV offices (2.2 μm).
引用
收藏
页码:729 / 740
页数:11
相关论文
共 50 条
  • [1] Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study
    Bragoszewska, Ewa, I
    Biedron, Izabela
    Kozielska, Barbara
    Pastuszka, Jozef S.
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2018, 11 (06): : 729 - 740
  • [2] Indoor air quality in urban nursery schools in Gliwice, Poland: Analysis of the case study
    Mainka, Anna
    Bragoszewska, Ewa
    Kozielska, Barbara
    Pastuszka, Jozef S.
    Zajusz-Zubek, Elwira
    [J]. ATMOSPHERIC POLLUTION RESEARCH, 2015, 6 (06) : 1098 - 1104
  • [3] STUDY OF INDOOR AIR QUALITY IN SELECTED OFFICE BUILDING
    Vilcekova, Silvia
    Estokova, Adriana
    Pilipova, Ivana
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [4] Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system
    Bonetta, Sa.
    Bonetta, Si.
    Mosso, S.
    Sampo, S.
    Carraro, E.
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 161 (1-4) : 473 - 483
  • [5] Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system
    Sa. Bonetta
    Si. Bonetta
    S. Mosso
    S. Sampò
    E. Carraro
    [J]. Environmental Monitoring and Assessment, 2010, 161 : 473 - 483
  • [6] Evaluation of indoor air quality and its symptoms in office building - A case study of Mashhad, Iran
    Atarodi, Zahra
    Karimyan, Kamaladdin
    Gupta, Vinod Kumar
    Abbasi, Morteza
    Moradi, Masoud
    [J]. DATA IN BRIEF, 2018, 20 : 74 - 79
  • [7] INDOOR AIR-QUALITY EVALUATION OF A NEW OFFICE BUILDING
    GROT, RA
    HODGSON, AT
    DAISEY, JM
    PERSILY, A
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1991, 33 (09): : 16 - &
  • [8] Monitored Indoor Environmental Quality of a Mass Timber Office Building: A Case Study
    Stenson, Jason
    Ishaq, Suzanne L.
    Laguerre, Aurelie
    Loia, Andrew
    MacCrone, Georgia
    Mugabo, Ignace
    Northcutt, Dale
    Riggio, Mariapaola
    Barbosa, Andre
    Gall, Elliott T.
    Van Den Wymelenberg, Kevin
    [J]. BUILDINGS, 2019, 9 (06)
  • [9] A Comparison of Sedimentation Method and Active Sampler Analysis of Microbiological Indoor Air Quality-Case Study
    Przystas, Wioletta
    Zablocka-Godlewska, Ewa
    Melaniuk-Wolny, Edyta
    [J]. ECOLOGICAL CHEMISTRY AND ENGINEERING S-CHEMIA I INZYNIERIA EKOLOGICZNA S, 2023, 30 (01): : 37 - 48
  • [10] THE EFFECTS OF REDUCED VENTILATION ON INDOOR AIR-QUALITY IN AN OFFICE BUILDING
    TURIEL, I
    HOLLOWELL, CD
    MIKSCH, RR
    RUDY, JV
    YOUNG, RA
    COYE, MJ
    [J]. ATMOSPHERIC ENVIRONMENT, 1983, 17 (01) : 51 - 64