Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method

被引:54
|
作者
Huang, Chuchu [1 ]
Li, Qing [1 ]
Mo, Jiamei [1 ]
Wang, Zheng [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC-BARRIER DISCHARGE; FLUORESCENCE SPECTROMETRY; ABSORPTION-SPECTROMETRY; ANALYTICAL PERFORMANCE; SIGNAL ENHANCEMENT; LIQUID CATHODE; SPECIATION; ANTIMONY; SAMPLES; CONTACT;
D O I
10.1021/acs.analchem.6b02807
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We herein describe a novel method of hydride generation (HG) coupled to a newly designed atmospheric pressure solution-cathode glow discharge (SCGD) spectrometric technique for the ultratrace determination of tin, germanium, and selenium. In this novel SCGD process, gas introduction was permitted using a hollow titanium tube as both the anode and sampling port. In these experiments, the analytes were converted into volatile hydrides upon passing through the hydride generator, and were introduced into the near-anode region of the SCGD system, where they were detected directly by atomic emission spectrometry (AES). A significant improvement in both selectivity and sensitivity was achieved, which was reflected in an improvement in the detection limits (DLs) by 3 orders of magnitude, in addition to successful valence analysis of Se without the requirement for chromatographic separation. In the absence of a strict sample pretreatment process and with a reduction in electrolyte consumption, the detection limits of Sn, Ge, and Se were determined to be 0.8, 0.5, and 0.2 mu g.L-1. Moreover, our HG-SCGD-AES system demonstrated excellent repeatability (<3% peak height relative standard deviation) and more than 2 orders of linear dynamic range. The optimal operating conditions are outlined herein, and the analytical performance of the system is evaluated as described. Furthermore, our method was applied for the analysis of Sn, Ge, and Se in both environmental and biological samples, and the obtained results were in good agreement with reference values.
引用
收藏
页码:11559 / 11567
页数:9
相关论文
共 50 条
  • [31] Analysis of Metal Elements Manganese Using Solution Cathode Glow Discharge-Atomic Emission Spectrometry with Portable Spectrographs
    Zheng Pei-chao
    Tang Peng-fei
    Wang Jin-mei
    Li Shi-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (05) : 1567 - 1571
  • [32] Rapid determination of indium in water samples using a portable solution cathode glow discharge-atomic emission spectrometer
    Zu, Wenchuan
    Yang, Yin
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    Ren, Min
    MICROCHEMICAL JOURNAL, 2018, 137 : 266 - 271
  • [33] Fundamental studies of electrolyte-as-cathode glow discharge-atomic emission spectrometry for the determination of trace metals in flowing water
    Park, YS
    Ku, SH
    Hong, SH
    Kim, HJ
    Piepmeier, EH
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) : 1167 - 1179
  • [34] Solution-cathode glow discharge - optical emission spectrometry of a new design and using a compact spectrograph
    Doroski, Todd A.
    King, Allison M.
    Fritz, Michael P.
    Webb, Michael R.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (07) : 1090 - 1095
  • [35] Ultrasensitive Determination of Selenium and Arsenic by Modified Helium Atmospheric Pressure Glow Discharge Optical Emission Spectrometry Coupled with Hydride Generation
    Peng, Xiaoxu
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2019, 91 (15) : 10073 - 10080
  • [36] Evaluation of interference filters for spectral discrimination in solution-cathode glow discharge optical emission spectrometry
    Schwartz, Andrew J.
    Ray, Steven J.
    Hieftje, Gary M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (06) : 1278 - 1286
  • [37] Determination of gallium in water samples by atomic emission spectrometry based on solution cathode glow discharge
    Li, Hongwei
    Zu, Wenchuan
    Liu, Fengkui
    Wang, Yu
    Yang, Yin
    Yang, Xiaotao
    Liu, Cong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 152 : 25 - 29
  • [38] Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry
    Yu, Jie
    Kang, Yuejing
    Lu, Quanfang
    Luo, Hui
    Cui, Lijuan
    Lu, Zhuanhong
    Li, Juanlong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 172
  • [39] Use of a solution cathode glow discharge for cold vapor generation of mercury with determination by ICP-atomic emission spectrometry
    Zhu, Zhenli
    Chan, George C. -Y.
    Ray, Steven J.
    Zhang, Xinrong
    Hieftje, Gary M.
    ANALYTICAL CHEMISTRY, 2008, 80 (18) : 7043 - 7050
  • [40] Automatable on-line generation of calibration curves and standard additions in solution-cathode glow discharge optical emission spectrometry
    Schwartz, Andrew. J.
    Ray, Steven J.
    Hieftje, Gary M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 105 : 77 - 83