Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry

被引:14
|
作者
Yu, Jie [1 ]
Kang, Yuejing [1 ]
Lu, Quanfang [1 ,2 ]
Luo, Hui [1 ]
Cui, Lijuan [1 ]
Lu, Zhuanhong [1 ]
Li, Juanlong [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic emission spectrometry (AES); Determination; Gallium; Indium; Solution cathode glow discharge (SCGD); DIELECTRIC-BARRIER DISCHARGE; FLOWING ELECTROLYTE-SOLUTIONS; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; WATER SAMPLES; ANALYTICAL PERFORMANCE; RAPID-DETERMINATION; ELEMENTAL ANALYSIS; HEAVY-METALS; ANODE;
D O I
10.1016/j.sab.2020.105968
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper, gallium (Ga) and indium (In) in water samples were determined by atomic emission spectrometry (AES) with solution cathode glow discharge (SCGD) as an excitation source. The optimal working conditions for the detection of Ga and In by proposed method are 660 V discharge voltage, 3.0 mL min(-1) solution flow rate and pH = 1.0 HNO3 as supporting electrolyte. Under these conditions, it is found that there are no obvious inter-ferences from most of the foreign ions when they exist in 20-fold excess over the In. But for Ga, the interferences from foreign ions are severe. The linear correlation coefficient (R-2) is better than 0.99 with a range of 1-40 mu g mL(-1) for Ga and 0.1-30 mu g mL(-1) for In. The limits of detection (LODs) for Ga and In are 0.10 and 0.016 mu g mL(-1), respectively. The relative standard deviations (RSDs) are 2.9% for Ga and 3.9% for In, and the power is below 55 W. To validate the utility and accuracy of the proposed system, two water samples spiked with various concentration (0.3-20 mu g mL(-1)) of Ga and In are directly determined, and the measured results are only in good agreement with spiked values of In. After diluted 10 times for water samples, the spiked values (0.3-20 mu g mL(-1)) of Ga agree well with the measured value, suggesting that the matrix can interfere with the determination of Ga. The satisfactory recoveries between 90% and 109% of In and Ga are achieved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of gallium in water samples by atomic emission spectrometry based on solution cathode glow discharge
    Li, Hongwei
    Zu, Wenchuan
    Liu, Fengkui
    Wang, Yu
    Yang, Yin
    Yang, Xiaotao
    Liu, Cong
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 152 : 25 - 29
  • [2] Liquid Cathode Glow Discharge as an Excitation Source for the Analysis of Complex Water Samples with Atomic Emission Spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Yin, Ling
    Feng, Feifei
    Luo, Hui
    Kang, Yuejing
    ACS OMEGA, 2020, 5 (31): : 19541 - 19547
  • [3] Liquid Cathode Glow Discharge as a Microplasma Excitation Source for Atomic Emission Spectrometry for the Determination of Trace Heavy Metals in Ore Samples
    Yu, Jie
    Zhu, Shuwen
    Lu, Quanfang
    Zhang, Zhichao
    Sun, Duixiong
    Zhang, Xiaomin
    Wang, Xing
    Yang, Wu
    ANALYTICAL LETTERS, 2018, 51 (13) : 2128 - 2140
  • [4] Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk
    Hao Jun
    Wang Yu
    Liu Cong
    Wu Zan
    Shao Peng
    Zu Wen-chuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3797 - 3801
  • [5] Direct determination of Cu by liquid cathode glow discharge-atomic emission spectrometry
    Lu, Quanfang
    Yang, Shuxiu
    Sun, Duixiong
    Zheng, Jidong
    Li, Yun
    Yu, Jie
    Su, Maogen
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 125 : 136 - 139
  • [6] Rapid determination of indium in water samples using a portable solution cathode glow discharge-atomic emission spectrometer
    Zu, Wenchuan
    Yang, Yin
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    Ren, Min
    MICROCHEMICAL JOURNAL, 2018, 137 : 266 - 271
  • [7] Advance in the excitation source in glow discharge optical emission spectrometry
    Wagatsuma, K
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2002, 88 (04): : 169 - 179
  • [8] Use of a solution cathode glow discharge for cold vapor generation of mercury with determination by ICP-atomic emission spectrometry
    Zhu, Zhenli
    Chan, George C. -Y.
    Ray, Steven J.
    Zhang, Xinrong
    Hieftje, Gary M.
    ANALYTICAL CHEMISTRY, 2008, 80 (18) : 7043 - 7050
  • [9] Application of Soluuion Cathode Glow Discharge-Atomic Emission Spectrometry in Determination of Lithium in Serum
    Liu Feng-kui
    Zu Wen-chuan
    Zhou Xiao-ping
    Liu Cong
    Liu Pan-xi
    Wang Yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (04) : 1252 - 1255
  • [10] Evaluation of flow injection-solution cathode glow discharge-atomic emission spectrometry for the determination of major elements in brines
    Yang, Chun
    Wang, Lin
    Zhu, Zhenli
    Jin, Lanlan
    Zheng, Hongtao
    Belshaw, Nicholas Stanley
    Hu, Shenghong
    TALANTA, 2016, 155 : 314 - 320