Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry

被引:14
|
作者
Yu, Jie [1 ]
Kang, Yuejing [1 ]
Lu, Quanfang [1 ,2 ]
Luo, Hui [1 ]
Cui, Lijuan [1 ]
Lu, Zhuanhong [1 ]
Li, Juanlong [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic emission spectrometry (AES); Determination; Gallium; Indium; Solution cathode glow discharge (SCGD); DIELECTRIC-BARRIER DISCHARGE; FLOWING ELECTROLYTE-SOLUTIONS; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; WATER SAMPLES; ANALYTICAL PERFORMANCE; RAPID-DETERMINATION; ELEMENTAL ANALYSIS; HEAVY-METALS; ANODE;
D O I
10.1016/j.sab.2020.105968
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper, gallium (Ga) and indium (In) in water samples were determined by atomic emission spectrometry (AES) with solution cathode glow discharge (SCGD) as an excitation source. The optimal working conditions for the detection of Ga and In by proposed method are 660 V discharge voltage, 3.0 mL min(-1) solution flow rate and pH = 1.0 HNO3 as supporting electrolyte. Under these conditions, it is found that there are no obvious inter-ferences from most of the foreign ions when they exist in 20-fold excess over the In. But for Ga, the interferences from foreign ions are severe. The linear correlation coefficient (R-2) is better than 0.99 with a range of 1-40 mu g mL(-1) for Ga and 0.1-30 mu g mL(-1) for In. The limits of detection (LODs) for Ga and In are 0.10 and 0.016 mu g mL(-1), respectively. The relative standard deviations (RSDs) are 2.9% for Ga and 3.9% for In, and the power is below 55 W. To validate the utility and accuracy of the proposed system, two water samples spiked with various concentration (0.3-20 mu g mL(-1)) of Ga and In are directly determined, and the measured results are only in good agreement with spiked values of In. After diluted 10 times for water samples, the spiked values (0.3-20 mu g mL(-1)) of Ga agree well with the measured value, suggesting that the matrix can interfere with the determination of Ga. The satisfactory recoveries between 90% and 109% of In and Ga are achieved.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Determination of Water Hardness by Electrolyte Cathode Atmospheric Glow Discharge Atomic Emission Spectroscopy
    Xi Xiao-Qin
    Zheng Pei-Chao
    Wang Hong-Mei
    Li Jian-Quan
    Han Hai-Yan
    Chu Yan-Nan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 449 - 452
  • [42] Discharge on boiling in a channel as a new atomization and excitation source for the flow determination of metals by atomic emission spectrometry
    Zuev, B.K.
    Yagov, V.V.
    Getsina, M.L.
    Rudenko, B.A.
    Zhurnal Analiticheskoj Khimii, 2002, 57 (10): : 1072 - 1077
  • [43] Discharge on Boiling in a Channel as a New Atomization and Excitation Source for the Flow Determination of Metals by Atomic Emission Spectrometry
    B. K. Zuev
    V. V. Yagov
    M. L. Getsina
    B. A. Rudenko
    Journal of Analytical Chemistry, 2002, 57 : 907 - 911
  • [44] Discharge on boiling in a channel as a new atomization and excitation source for the flow determination of metals by atomic emission spectrometry
    Zuev, BK
    Yagov, VV
    Getsina, ML
    Rudenko, BA
    JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (10) : 907 - 911
  • [45] Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury
    Mo, Jiamei
    Li, Qing
    Guo, Xiaohong
    Zhang, Guoxia
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10353 - 10360
  • [46] Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method
    Huang, Chuchu
    Li, Qing
    Mo, Jiamei
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2016, 88 (23) : 11559 - 11567
  • [47] Solution cathode glow discharge induced vapor generation of iodine for determination by inductively coupled plasma optical emission spectrometry
    Zhu, Zhenli
    He, Qian
    Shuai, Qin
    Zheng, Hongtao
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (09) : 1390 - 1394
  • [48] A GLOW-DISCHARGE DEVICE FOR ATOMIC EMISSION-SPECTROMETRY OF MICROLITER SOLUTION SAMPLES
    BRACKETT, JM
    VICKERS, TJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1982, 37 (10) : 841 - 847
  • [49] A pulsed Grimm glow discharge as an atomic emission source
    Yang, CL
    Ingeneri, K
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) : 693 - 698
  • [50] Spatially-resolved Observation of the Excitation Temperature in a Glow Discharge Plasma for Atomic Emission Spectrometry
    Matsuura, Munehiko
    Wagatsuma, Kazuaki
    ANALYTICAL SCIENCES, 2011, 27 (03) : 231 - 235