Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry

被引:14
|
作者
Yu, Jie [1 ]
Kang, Yuejing [1 ]
Lu, Quanfang [1 ,2 ]
Luo, Hui [1 ]
Cui, Lijuan [1 ]
Lu, Zhuanhong [1 ]
Li, Juanlong [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic emission spectrometry (AES); Determination; Gallium; Indium; Solution cathode glow discharge (SCGD); DIELECTRIC-BARRIER DISCHARGE; FLOWING ELECTROLYTE-SOLUTIONS; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; WATER SAMPLES; ANALYTICAL PERFORMANCE; RAPID-DETERMINATION; ELEMENTAL ANALYSIS; HEAVY-METALS; ANODE;
D O I
10.1016/j.sab.2020.105968
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper, gallium (Ga) and indium (In) in water samples were determined by atomic emission spectrometry (AES) with solution cathode glow discharge (SCGD) as an excitation source. The optimal working conditions for the detection of Ga and In by proposed method are 660 V discharge voltage, 3.0 mL min(-1) solution flow rate and pH = 1.0 HNO3 as supporting electrolyte. Under these conditions, it is found that there are no obvious inter-ferences from most of the foreign ions when they exist in 20-fold excess over the In. But for Ga, the interferences from foreign ions are severe. The linear correlation coefficient (R-2) is better than 0.99 with a range of 1-40 mu g mL(-1) for Ga and 0.1-30 mu g mL(-1) for In. The limits of detection (LODs) for Ga and In are 0.10 and 0.016 mu g mL(-1), respectively. The relative standard deviations (RSDs) are 2.9% for Ga and 3.9% for In, and the power is below 55 W. To validate the utility and accuracy of the proposed system, two water samples spiked with various concentration (0.3-20 mu g mL(-1)) of Ga and In are directly determined, and the measured results are only in good agreement with spiked values of In. After diluted 10 times for water samples, the spiked values (0.3-20 mu g mL(-1)) of Ga agree well with the measured value, suggesting that the matrix can interfere with the determination of Ga. The satisfactory recoveries between 90% and 109% of In and Ga are achieved.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Ultrasensitive determination of mercury by solution anode glow discharge atomic emission spectrometry coupled with hydride generation
    Yuan, Mingli
    Peng, Xiaoxu
    Ge, Fen
    Zhao, Mingyue
    Li, Qing
    Wang, Zheng
    CHINESE CHEMICAL LETTERS, 2020, 31 (10) : 2814 - 2818
  • [32] Optimization of hollow cathode diameter for particle beam/hollow cathode glow discharge atomic emission spectrometry
    Dempster, MA
    Marcus, RK
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (06) : 599 - 610
  • [33] Solution Cathode Glow Discharge - Atomic Emission Spectrometry (SCGD-AES) With an Interference Filter for Spectral Discrimination for the Determination of Thallium in Surface Water
    Wang, Jinmei
    Fei, Guoxing
    Zheng, Peichao
    Yan, Nantian
    Chen, Guanghui
    Li, Wei
    Dong, Daming
    Guo, Lianbo
    ANALYTICAL LETTERS, 2024,
  • [34] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422
  • [35] A portable solution cathode glow discharge-atomic emission spectrometer for the rapid determination of thallium in water samples
    Zu, Wenchuan
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    TALANTA, 2017, 173 : 88 - 93
  • [36] Determination of Metals by Portable Millisecond Pulsed Solution Cathode Glow Discharge (SCGD) Atomic Emission Spectroscopy (AES)
    Zheng, Peichao
    Wang, Ningshen
    Wang, Jinmei
    Qazi, Hafiz Imran Ahmad
    Tian, Hongwu
    Dong, Daming
    He, Yuxin
    Wu, Meini
    ANALYTICAL LETTERS, 2024, 57 (06) : 855 - 865
  • [37] Analysis of Metal Elements Manganese Using Solution Cathode Glow Discharge-Atomic Emission Spectrometry with Portable Spectrographs
    Zheng Pei-chao
    Tang Peng-fei
    Wang Jin-mei
    Li Shi-yu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (05) : 1567 - 1571
  • [38] Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry
    Schwartz, Andrew J.
    Williams, Kelsey L.
    Hieftje, Gary M.
    Shelley, Jacob T.
    ANALYTICA CHIMICA ACTA, 2017, 950 : 119 - 128
  • [39] Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Yang, Shuxiu
    Sun, Duixiong
    Lu, Quanfang
    Zheng, Jidong
    Zhang, Xiaomei
    Wang, Xing
    MICROCHEMICAL JOURNAL, 2016, 128 : 325 - 330
  • [40] A novel solution cathode glow discharge geometry for improved coupling to optical emission spectrometry
    Hazel, Nicholas
    Orejas Ibanez, Jaime
    Ray, Steven