Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method

被引:54
|
作者
Huang, Chuchu [1 ]
Li, Qing [1 ]
Mo, Jiamei [1 ]
Wang, Zheng [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC-BARRIER DISCHARGE; FLUORESCENCE SPECTROMETRY; ABSORPTION-SPECTROMETRY; ANALYTICAL PERFORMANCE; SIGNAL ENHANCEMENT; LIQUID CATHODE; SPECIATION; ANTIMONY; SAMPLES; CONTACT;
D O I
10.1021/acs.analchem.6b02807
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We herein describe a novel method of hydride generation (HG) coupled to a newly designed atmospheric pressure solution-cathode glow discharge (SCGD) spectrometric technique for the ultratrace determination of tin, germanium, and selenium. In this novel SCGD process, gas introduction was permitted using a hollow titanium tube as both the anode and sampling port. In these experiments, the analytes were converted into volatile hydrides upon passing through the hydride generator, and were introduced into the near-anode region of the SCGD system, where they were detected directly by atomic emission spectrometry (AES). A significant improvement in both selectivity and sensitivity was achieved, which was reflected in an improvement in the detection limits (DLs) by 3 orders of magnitude, in addition to successful valence analysis of Se without the requirement for chromatographic separation. In the absence of a strict sample pretreatment process and with a reduction in electrolyte consumption, the detection limits of Sn, Ge, and Se were determined to be 0.8, 0.5, and 0.2 mu g.L-1. Moreover, our HG-SCGD-AES system demonstrated excellent repeatability (<3% peak height relative standard deviation) and more than 2 orders of linear dynamic range. The optimal operating conditions are outlined herein, and the analytical performance of the system is evaluated as described. Furthermore, our method was applied for the analysis of Sn, Ge, and Se in both environmental and biological samples, and the obtained results were in good agreement with reference values.
引用
收藏
页码:11559 / 11567
页数:9
相关论文
共 50 条
  • [1] Ultratrace Pb determination in seawater by solution-cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Cheng, Junqi
    Li, Qing
    Zhao, Mingyue
    Wang, Zheng
    ANALYTICA CHIMICA ACTA, 2019, 1077 : 107 - 115
  • [2] Elemental Analysis of Mineral Water by Solution-Cathode Glow Discharge-Atomic Emission Spectrometry
    Zheng, Peichao
    Gong, Yaming
    Wang, Jinmei
    Zeng, Xiaobo
    ANALYTICAL LETTERS, 2017, 50 (09) : 1512 - 1520
  • [3] Determination of silicate by hollow cathode glow discharge-atomic emission spectrometry with hydride generation technique
    Fujiwara, K
    Wagner, EP
    Smith, BW
    Winefordner, JD
    ANALYTICAL LETTERS, 1996, 29 (11) : 1985 - 1992
  • [4] Solution Cathode Glow Discharge-Atomic Emission Spectroscopy Coupled With Hydride Generation for Detecting Trace Mercury and Tin in Water
    Zheng Pei-chao
    Liu Ran-ning
    Wang Jin-mei
    Feng Chu-hui
    He Yu-tong
    Wu Mei-ni
    He Yu-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (04) : 1139 - 1143
  • [5] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422
  • [6] Determination of Trace Metals in Lutetium-Yttrium Orthosilicate by Solution-Cathode Glow Discharge-Atomic Emission Spectrometry
    Gai Rong-Yin
    Wang Zheng
    He Yan-Feng
    Li Qing
    Zou Hui-Jun
    Zhang Guo-Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (11) : 1617 - 1622
  • [7] On-line separation and preconcentration of hexavalent chromium on a novel mesoporous silica adsorbent with determination by solution-cathode glow discharge-atomic emission spectrometry
    Ma, Jiaxian
    Wang, Zheng
    Li, Qing
    Gai, Rongyin
    Li, Xiaohong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2315 - 2322
  • [8] Design modification of a solution-cathode glow discharge-atomic emission spectrometer for the determination of trace metals in titanium dioxide
    Wang, Zheng
    Gai, Rongyin
    Zhou, Lei
    Zhang, Zhen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (11) : 2042 - 2049
  • [10] Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk
    Hao Jun
    Wang Yu
    Liu Cong
    Wu Zan
    Shao Peng
    Zu Wen-chuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3797 - 3801