Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method

被引:54
|
作者
Huang, Chuchu [1 ]
Li, Qing [1 ]
Mo, Jiamei [1 ]
Wang, Zheng [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Ceram, Shanghai 200050, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC-BARRIER DISCHARGE; FLUORESCENCE SPECTROMETRY; ABSORPTION-SPECTROMETRY; ANALYTICAL PERFORMANCE; SIGNAL ENHANCEMENT; LIQUID CATHODE; SPECIATION; ANTIMONY; SAMPLES; CONTACT;
D O I
10.1021/acs.analchem.6b02807
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We herein describe a novel method of hydride generation (HG) coupled to a newly designed atmospheric pressure solution-cathode glow discharge (SCGD) spectrometric technique for the ultratrace determination of tin, germanium, and selenium. In this novel SCGD process, gas introduction was permitted using a hollow titanium tube as both the anode and sampling port. In these experiments, the analytes were converted into volatile hydrides upon passing through the hydride generator, and were introduced into the near-anode region of the SCGD system, where they were detected directly by atomic emission spectrometry (AES). A significant improvement in both selectivity and sensitivity was achieved, which was reflected in an improvement in the detection limits (DLs) by 3 orders of magnitude, in addition to successful valence analysis of Se without the requirement for chromatographic separation. In the absence of a strict sample pretreatment process and with a reduction in electrolyte consumption, the detection limits of Sn, Ge, and Se were determined to be 0.8, 0.5, and 0.2 mu g.L-1. Moreover, our HG-SCGD-AES system demonstrated excellent repeatability (<3% peak height relative standard deviation) and more than 2 orders of linear dynamic range. The optimal operating conditions are outlined herein, and the analytical performance of the system is evaluated as described. Furthermore, our method was applied for the analysis of Sn, Ge, and Se in both environmental and biological samples, and the obtained results were in good agreement with reference values.
引用
收藏
页码:11559 / 11567
页数:9
相关论文
共 50 条
  • [41] Ultratrace determination of tin by hydride generation in-atomizer trapping atomic absorption spectrometry
    Prusa, Libor
    Dedina, Jiri
    Kratzer, Jan
    ANALYTICA CHIMICA ACTA, 2013, 804 : 50 - 58
  • [42] Solution cathode glow discharge induced vapor generation of iodine for determination by inductively coupled plasma optical emission spectrometry
    Zhu, Zhenli
    He, Qian
    Shuai, Qin
    Zheng, Hongtao
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (09) : 1390 - 1394
  • [43] Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity
    Zhang, Zhen
    Wang, Zheng
    Li, Qing
    Zou, Huijun
    Shi, Ying
    TALANTA, 2014, 119 : 613 - 619
  • [44] Determination of Ultratrace Selenium and Arsenic in Drinking Water by Electrochemical Hydride Generation Coupled with Quartz Furnace - Atomic Absorption Spectrometry
    Hranicek, Jakub
    Cerveny, Vaclav
    Rychlovsky, Petr
    CHEMICKE LISTY, 2010, 104 (12): : 1196 - 1203
  • [45] On the coupling of hydride generation with atmospheric pressure glow discharge in contact with the flowing liquid cathode for the determination of arsenic, antimony and selenium with optical emission spectrometry
    Greda, Krzysztof
    Jamroz, Piotr
    Jedryczko, Dominika
    Pohl, Pawel
    TALANTA, 2015, 137 : 11 - 17
  • [46] DETERMINATION OF GERMANIUM, ARSENIC, TIN, SELENIUM, AND ANTIMONY BY PLASMA EMISSION SPECTROMETRY WITH HYDRIDE GENERATION AND CHROMATOGRAPHIC-SEPARATION
    FRICKE, FL
    ROBBINS, WD
    CARUSO, JA
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1978, 61 (05): : 1118 - 1123
  • [47] On-line separation and pre-concentration on a mesoporous silica-grafted graphene oxide adsorbent coupled with solution cathode glow discharge-atomic emission spectrometry for the determination of lead
    Mo, Jiamei
    Zhou, Lei
    Li, Xiaohong
    Li, Qing
    Wang, Lianjun
    Wang, Zheng
    MICROCHEMICAL JOURNAL, 2017, 130 : 353 - 359
  • [48] Determination of Hg2+ by on-line separation and pre-concentration with atmospheric-pressure solution-cathode glow discharge atomic emission spectrometry
    Li, Qing
    Zhang, Zhen
    Wang, Zheng
    ANALYTICA CHIMICA ACTA, 2014, 845 : 7 - 14
  • [49] Elemental Analysis of Environmental Waters by Solution Cathode Glow Discharge-Atomic Emission Spectrometry (SCGD-AES) with a Multifunctional Injection System
    Zheng, Peichao
    Hu, Qiang
    Zhang, Hangxi
    Wang, Jinmei
    Yang, Yang
    He, Yuxin
    Wu, Meini
    Tian, Hongwu
    Dong, Daming
    Mao, Xuefeng
    Lai, Chunhong
    ANALYTICAL LETTERS, 2022, 55 (14) : 2273 - 2285
  • [50] DETERMINATION OF GERMANIUM, ARSENIC, SELENIUM, TIN AND ANTIMONY IN COMPLEX SAMPLES BY HYDRIDE GENERATION - MICROWAVE-INDUCED PLASMA ATOMIC-EMISSION SPECTROMETRY
    ROBBINS, WB
    CARUSO, JA
    FRICKE, FL
    ANALYST, 1979, 104 (1234) : 35 - 40