Evaluation of a physiologic pulsatile pump system for neonate-infant cardiopulmonary bypass support

被引:0
|
作者
Ündar, A
Masai, T
Inman, R
Beyer, EA
Mueller, MA
McGarry, MC
Frazier, OH
Fraser, CD
机构
[1] Texas Childrens Hosp, Baylor Coll Med, Congenital Heart Surg Serv, Houston, TX 77030 USA
[2] Baylor Coll Med, Texas Heart Inst, Cullen Cardiovasc Surg Res Labs, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Surg, Sect Congenital Heart Surg, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An alternate physiologic pulsatile pump (PPP) system was designed and evaluated to produce sufficient pulsatility during neonate-infant open heart surgery. This hydraulically driven pump system has a unique "dual" pumping chamber mechanism. The first chamber is placed between the venous reservoir and oxygenator and the second chamber between the oxygenator and patient. Each chamber has two unidirectional tricuspid valves. Stroke volume (0.2-10 ml), upstroke rise time (10-350 msec), and pump rate (2-250 beats per minute [bpm]) can be adjusted independently to produce adequate pulsatility. This system has been tested in 3-kg piglets (n = 6), with a pump flow of 150 ml/kg/min, a pump rate of 150 bpm, and a pump ejection time of 110 msec. After initiation of cardiopulmonary bypass (CPB), all animals were subjected to 25 minutes of hypothermia to reduce the rectal temperatures to 18 degrees C, 60 minutes of deep hypothermic circulatory arrest (DHCA), then 10 minutes of cold perfusion with a full pump flow, and 40 minutes of rewarming. During CPB, mean arterial pressures were kept at less than 50 mm Hg. Mean extracorporeal circuit pressure (ECCP), the pressure drop of a 10 French aortic cannula, and the pulse pressure were 67 +/- 9, 21 +/- 6, and 16 +/- 2 mm Hg, respectively. All values are represented as mean +/- SD. No regurgitation or abnormal hemolysis has been detected during these experiments. The oxygenator had no damping effect on the quality of the pulsatility because of the dual chamber pumping mechanism. The ECCP was also significantly lower than any other known pulsatile system. We conclude that this system, with a 10 French aortic cannula and arterial filter, produces adequate pulsatility in 3 kg piglets.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [1] Design and performance of a physiologic pulsatile flow neonate-infant cardiopulmonary bypass system
    Undar, Akif
    Lodge, Andrew J.
    Runge, Thomas M.
    Daggett, Casey W.
    Ungerleider, Ross M.
    Calhoon, John H.
    ASAIO Journal, 1996, 24 (05):
  • [2] Design and performance of a physiologic pulsatile flow neonate-infant cardiopulmonary bypass system
    Undar, A
    Lodge, AJ
    Runge, TM
    Daggett, CW
    Ungerleider, RM
    Calhoon, JH
    ASAIO JOURNAL, 1996, 42 (05) : M580 - M583
  • [3] Testing neonate-infant membrane oxygenators with the University of Texas neonatal pulsatile cardiopulmonary bypass system in vitro
    Uendar, Akif
    Holland, Marian C.
    Howelton, Russel V.
    Benson, Cherie K.
    Ybarra, Jose R.
    Miller, O. LaWayne
    Rossbach, Mario M.
    Runge, Thomas M.
    Johnson, Scott B.
    Sako, Edward Y.
    Calhoon, John H.
    PERFUSION-UK, 1998, 13 (05): : 346 - 352
  • [4] The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo
    Undar, A
    Lodge, AJ
    Daggett, CW
    Runge, TM
    Ungerleider, RM
    Calhoon, JH
    ARTIFICIAL ORGANS, 1998, 22 (08) : 681 - 686
  • [5] PULSATILE PUMP CONTROL IN CARDIOPULMONARY BYPASS SYSTEM
    TUCHIYA, K
    UMEZU, M
    FUJIMOTO, T
    TOMINO, T
    ARTIFICIAL ORGANS, 1980, 4 (02) : 150 - 150
  • [6] PULSATILE FLOW DURING CARDIOPULMONARY BYPASS - EVALUATION OF A NEW PULSATILE PUMP
    WAABEN, J
    ANDERSEN, K
    HUSUM, B
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 19 (02): : 149 - 153
  • [7] Design of a physiologic pulsatile flow cardiopulmonary bypass system for neonates and infants
    Undar, A
    Runge, TM
    Miller, OL
    Felger, MC
    Lansing, R
    Korvick, DL
    Bohls, FO
    Ottmers, SE
    ODell, BJ
    Ybarra, JR
    Howelton, RV
    Mireles, RZ
    Benson, CK
    Holland, MC
    Calhoon, JH
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (03): : 170 - 176
  • [8] Hemodynamic evaluation of a new pulsatile blood pump during low flow cardiopulmonary bypass support
    Miyamoto, Takuma
    Sunagawa, Gengo
    Dessoffy, Raymond
    Karimov, Jamshid H.
    Grady, Patrick
    Naber, Jeffrey P.
    Vincent, Douglas
    Sale, Shiva M.
    Kvernebo, Knut
    Tran, Van N. P.
    Moazami, Nader
    Fukamachi, Kiyotaka
    ARTIFICIAL ORGANS, 2022, 46 (04) : 643 - 652
  • [9] COMPUTER-CONTROLLED PULSATILE ROLLER-PUMP FOR AN INFANT CARDIOPULMONARY BYPASS
    FUKUI, Y
    TSUCHIYA, K
    SATO, K
    IMAI, Y
    SUGAWARA, M
    TAKANASHI, Y
    HONDA, M
    SOEJIMA, K
    ARTIFICIAL ORGANS, 1981, 5 (03) : 320 - 320
  • [10] CLINICAL-EXPERIENCE WITH A NEW PULSATILE PUMP FOR INFANT AND PEDIATRIC CARDIOPULMONARY BYPASS
    FUMERO, R
    MONTEVECCHI, FM
    SCURI, S
    CARRARA, B
    GAMBA, A
    PARENZAN, L
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1989, 12 (05): : 314 - 320