Development of integrated prompt gamma imaging and positron emission tomography system for in vivo 3-D dose verification: a Monte Carlo study

被引:14
|
作者
Choi, Hyun Joon [1 ]
Jang, Ji Won [1 ]
Shin, Wook-Geun [1 ]
Park, Hyojun [1 ]
Incerti, Sebastien [2 ,3 ]
Min, Chul Hee [1 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju 26493, South Korea
[2] Bordeaux Univ, UMR 5797, F-33170 Gradignan, France
[3] CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 10期
基金
新加坡国家研究基金会;
关键词
proton therapy; prompt gamma imaging; positron emission tomography; in vivo dose verification; Monte Carlo; CONVOLUTIONAL NEURAL-NETWORK; RANGE VERIFICATION; PROTON-BEAMS; THERAPY; PATIENT; CT; SEGMENTATION; VALIDATION; PREDICTION;
D O I
10.1088/1361-6560/ab857c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate knowledge of in vivo proton dose distribution is key to fully utilizing the potential advantages of proton therapy. Two representative indirect methods for in vivo range verification, namely, prompt gamma (PG) imaging and positron emission tomography (PET), are available. This study proposes a PG-PET system that combines the advantages of these two methods and presents detector geometry and background reduction techniques optimized for the PG-PET system. The characteristics of the secondary radiations emitted by a water phantom by interaction with a 150 MeV proton beam were analysed using Geant4.10.00, and the 2-D PG distributions were obtained and assessed for different detector geometries. In addition, the energy window (EW), depth-of-interaction (DOI), and time-of-flight (TOF) techniques are proposed as the background reduction techniques. To evaluate the performance of the PG-PET system, the 3-D dose distribution in the water phantom caused by two proton beams of energies 80 MeV and 100 MeV was verified using 16 optimal detectors. The thickness of the parallel-hole tungsten collimator of pitch 8 mm and width 7 mm was determined as 200 mm, and that of the GAGG scintillator was determined as 30 mm, by an optimization study. Further, 3-7 MeV and 2-7 MeV were obtained as the optimal EWs when the DOI and both the DOI and TOF techniques were applied for data processing, respectively; the detector performances were improved by about 38% and 167%, respectively, compared with that when applying only the 3-5 MeV EW. In this study, we confirmed that the PG distribution can be obtained by simply combining the 2-D parallel hole collimator and the PET detector module. In the future, we will develop an accurate 3-D dose evaluation technique using deep learning algorithms based on the image sets of dose, PG, and PET distributions for various proton energies.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] A Spectroscopic Diffuse Optical Tomography System for the Continuous 3-D Functional Imaging of Tissue - A Phantom Study
    Saikia, Manob Jyoti
    IEEE Transactions on Instrumentation and Measurement, 2021, 70
  • [42] Performance of An Improved Optical Computed Tomography Polymer Gel Dosimeter System for 3-D Dose Verification of Static and Dynamic Phantom Deliveries
    Lopatiuk-Tirpak, O.
    Langen, K.
    Meeks, S.
    Kupelian, P.
    Maryanski, M.
    Zeidan, O.
    MEDICAL PHYSICS, 2008, 35 (06) : 2791 - +
  • [43] In vivo imaging of dopamine D1 receptor and activated microglia in attention-deficit/hyperactivity disorder: a positron emission tomography study
    Yokokura, Masamichi
    Takebasashi, Kiyokazu
    Takao, Akiyo
    Nakaizumi, Kyoko
    Yoshikawa, Etsuji
    Futatsubashi, Masami
    Suzuki, Katsuaki
    Nakamura, Kazuhiko
    Yamasue, Hidenori
    Ouchi, Yasuomi
    MOLECULAR PSYCHIATRY, 2021, 26 (09) : 4958 - 4967
  • [44] In vivo imaging of dopamine D1 receptor and activated microglia in attention-deficit/hyperactivity disorder: a positron emission tomography study
    Masamichi Yokokura
    Kiyokazu Takebasashi
    Akiyo Takao
    Kyoko Nakaizumi
    Etsuji Yoshikawa
    Masami Futatsubashi
    Katsuaki Suzuki
    Kazuhiko Nakamura
    Hidenori Yamasue
    Yasuomi Ouchi
    Molecular Psychiatry, 2021, 26 : 4958 - 4967
  • [45] In Vivo Imaging of Dopamine D3 Receptors in Alcoholism Using Positron Emission Tomography, [11C]PHNO, and a Selective D3 Receptor Antagonist
    Erritzoe, David
    Tziortzi, Andri
    Bargiela, David
    Searle, Graham
    Gunn, Roger N.
    Beaver, John D.
    Waldman, Adam
    Nutt, David
    Bani, Massimo
    Merlo-Pich, Emilio
    Rabiner, Eugenii A.
    Lingford-Hughes, Anne
    BIOLOGICAL PSYCHIATRY, 2011, 69 (09) : 271S - 271S
  • [46] Preliminary study of integrated C-arm CT/SPECT imaging system for online adaptive 3D brachytherapy using Monte Carlo simulation
    Lee, M.
    Lee, H.
    Seong, S.
    Park, H.
    Kim, H.
    Min, C.
    Choi, H.
    Choa, H.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [47] Endogenous Dopamine (DA) Competes With the Binding of a Radiolabeled D3 Receptor Partial Agonist In Vivo: A Positron Emission Tomography Study
    Mach, Robert H.
    Tu, Zhude
    Xu, Jinbin
    Li, Shihong
    Jones, Lynne A.
    Taylor, Michelle
    Luedtke, Robert R.
    Derdeyn, Colin P.
    Perlmutter, Joel S.
    Mintun, Mark A.
    SYNAPSE, 2011, 65 (08) : 724 - 732
  • [48] Automatic 3D Monte-Carlo-based secondary dose calculation for online verification of 1.5 T magnetic resonance imaging guided radiotherapy
    Nachbar, Marcel
    Monnich, David
    Dohm, Oliver
    Friedlein, Melissa
    Zips, Daniel
    Thorwarth, Daniela
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 19 : 6 - 12
  • [49] Achieving sub-100 ps time-of-flight resolution in thick LSO positron emission tomography while reducing system cost: a Monte Carlo study
    Walrand, Stephan
    Hesse, Michel
    Jamar, Francois
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (20):
  • [50] A Spectroscopic Diffuse Optical Tomography System for the Continuous 3-D Functional Imaging of Tissue-A Phantom Study
    Saikia, Manob Jyoti
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70