Development of integrated prompt gamma imaging and positron emission tomography system for in vivo 3-D dose verification: a Monte Carlo study

被引:14
|
作者
Choi, Hyun Joon [1 ]
Jang, Ji Won [1 ]
Shin, Wook-Geun [1 ]
Park, Hyojun [1 ]
Incerti, Sebastien [2 ,3 ]
Min, Chul Hee [1 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju 26493, South Korea
[2] Bordeaux Univ, UMR 5797, F-33170 Gradignan, France
[3] CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 10期
基金
新加坡国家研究基金会;
关键词
proton therapy; prompt gamma imaging; positron emission tomography; in vivo dose verification; Monte Carlo; CONVOLUTIONAL NEURAL-NETWORK; RANGE VERIFICATION; PROTON-BEAMS; THERAPY; PATIENT; CT; SEGMENTATION; VALIDATION; PREDICTION;
D O I
10.1088/1361-6560/ab857c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate knowledge of in vivo proton dose distribution is key to fully utilizing the potential advantages of proton therapy. Two representative indirect methods for in vivo range verification, namely, prompt gamma (PG) imaging and positron emission tomography (PET), are available. This study proposes a PG-PET system that combines the advantages of these two methods and presents detector geometry and background reduction techniques optimized for the PG-PET system. The characteristics of the secondary radiations emitted by a water phantom by interaction with a 150 MeV proton beam were analysed using Geant4.10.00, and the 2-D PG distributions were obtained and assessed for different detector geometries. In addition, the energy window (EW), depth-of-interaction (DOI), and time-of-flight (TOF) techniques are proposed as the background reduction techniques. To evaluate the performance of the PG-PET system, the 3-D dose distribution in the water phantom caused by two proton beams of energies 80 MeV and 100 MeV was verified using 16 optimal detectors. The thickness of the parallel-hole tungsten collimator of pitch 8 mm and width 7 mm was determined as 200 mm, and that of the GAGG scintillator was determined as 30 mm, by an optimization study. Further, 3-7 MeV and 2-7 MeV were obtained as the optimal EWs when the DOI and both the DOI and TOF techniques were applied for data processing, respectively; the detector performances were improved by about 38% and 167%, respectively, compared with that when applying only the 3-5 MeV EW. In this study, we confirmed that the PG distribution can be obtained by simply combining the 2-D parallel hole collimator and the PET detector module. In the future, we will develop an accurate 3-D dose evaluation technique using deep learning algorithms based on the image sets of dose, PG, and PET distributions for various proton energies.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy
    Parodi, Katia
    Paganetti, Harald
    Shih, Helen A.
    Michaud, Susan
    Loeffler, Jay S.
    DeLaney, Thomas F.
    Liebsch, Norbert J.
    Munzenrider, John E.
    Fischman, Alan J.
    Knopf, Antje
    Bortfeld, Thomas
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03): : 920 - 934
  • [22] A feasibility study on gamma-ray tomography by Monte Carlo simulation for development of portable tomographic system
    Kim, Jongbum
    Jung, Sunghee
    Moon, Jinho
    Cho, Gyuseong
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (02) : 404 - 414
  • [23] Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations
    Adam, LE
    Karp, JS
    Brix, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : 2879 - 2895
  • [24] Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study
    Lartizien, Carole
    Marache-Francisco, Simon
    Prost, Remy
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 102 - 112
  • [25] Development of a new prompt gamma ray detection system for full 3D proton range verification
    Costanza, P.
    Mackay, R. I.
    Kirkby, K. J.
    Taylor, M. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S957 - S958
  • [26] Optimization of single-photon emission computed tomography system for fast verification of spent fuel assembly: a Monte Carlo study
    Choi, H. J.
    Kang, I. S.
    Kim, K. B.
    Chung, Y. H.
    Min, C. H.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [27] Clinical application of imaging techniques in advanced frontotemporal lobar degeneration:: 3-D MRI morphometry and positron emission tomography
    Kassubek, J
    Juengling, FD
    Sperfeld, AD
    Wunderlich, A
    Grön, G
    NERVENHEILKUNDE, 2002, 21 (04) : 214 - 218
  • [28] Prompt Gamma 2D Imaging With a Slit-Slat Gamma Camera For Real-TimeTreatment Monitoring in Protontherapy: Monte Carlo Simulation Study
    Malekzadeh, E.
    Rajabi, H.
    Sabouri, P.
    Fiorina, E.
    Kalantari, F.
    MEDICAL PHYSICS, 2022, 49 (06) : E205 - E205
  • [29] Development and performance verification of a 3-D position-sensitive Compton camera for imaging MeV gamma rays
    Hiroki Hosokoshi
    Jun Kataoka
    Saku Mochizuki
    Masaki Yoneyama
    Soichiro Ito
    Hiroaki Kiji
    Fumiya Nishi
    Shuji Miyamoto
    Tatsushi Shima
    Scientific Reports, 9
  • [30] Development and performance verification of a 3-D position-sensitive Compton camera for imaging MeV gamma rays
    Hosokoshi, Hiroki
    Kataoka, Jun
    Mochizuki, Saku
    Yoneyama, Masaki
    Ito, Soichiro
    Kiji, Hiroaki
    Nishi, Fumiya
    Miyamoto, Shuji
    Shima, Tatsushi
    SCIENTIFIC REPORTS, 2019, 9 (1)