Development of integrated prompt gamma imaging and positron emission tomography system for in vivo 3-D dose verification: a Monte Carlo study

被引:14
|
作者
Choi, Hyun Joon [1 ]
Jang, Ji Won [1 ]
Shin, Wook-Geun [1 ]
Park, Hyojun [1 ]
Incerti, Sebastien [2 ,3 ]
Min, Chul Hee [1 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju 26493, South Korea
[2] Bordeaux Univ, UMR 5797, F-33170 Gradignan, France
[3] CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 10期
基金
新加坡国家研究基金会;
关键词
proton therapy; prompt gamma imaging; positron emission tomography; in vivo dose verification; Monte Carlo; CONVOLUTIONAL NEURAL-NETWORK; RANGE VERIFICATION; PROTON-BEAMS; THERAPY; PATIENT; CT; SEGMENTATION; VALIDATION; PREDICTION;
D O I
10.1088/1361-6560/ab857c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate knowledge of in vivo proton dose distribution is key to fully utilizing the potential advantages of proton therapy. Two representative indirect methods for in vivo range verification, namely, prompt gamma (PG) imaging and positron emission tomography (PET), are available. This study proposes a PG-PET system that combines the advantages of these two methods and presents detector geometry and background reduction techniques optimized for the PG-PET system. The characteristics of the secondary radiations emitted by a water phantom by interaction with a 150 MeV proton beam were analysed using Geant4.10.00, and the 2-D PG distributions were obtained and assessed for different detector geometries. In addition, the energy window (EW), depth-of-interaction (DOI), and time-of-flight (TOF) techniques are proposed as the background reduction techniques. To evaluate the performance of the PG-PET system, the 3-D dose distribution in the water phantom caused by two proton beams of energies 80 MeV and 100 MeV was verified using 16 optimal detectors. The thickness of the parallel-hole tungsten collimator of pitch 8 mm and width 7 mm was determined as 200 mm, and that of the GAGG scintillator was determined as 30 mm, by an optimization study. Further, 3-7 MeV and 2-7 MeV were obtained as the optimal EWs when the DOI and both the DOI and TOF techniques were applied for data processing, respectively; the detector performances were improved by about 38% and 167%, respectively, compared with that when applying only the 3-5 MeV EW. In this study, we confirmed that the PG distribution can be obtained by simply combining the 2-D parallel hole collimator and the PET detector module. In the future, we will develop an accurate 3-D dose evaluation technique using deep learning algorithms based on the image sets of dose, PG, and PET distributions for various proton energies.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Conceptual detector development and Monte Carlo simulation of a novel 3D breast computed tomography system
    Ziegle, Jens
    Mueller, Bernhard H.
    Neumann, Bernd
    Hoeschen, Christoph
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [32] Imaging the D3 receptor in humans in vivo using [11C]-PHNO positron emission tomography (PET)
    Rabiner, Eugenii A.
    Laruelle, Marc
    INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2010, 13 (03): : 289 - 290
  • [33] Development of an array-type prompt gamma detection system for the online measurement of the range of the proton beam in a patient: a Monte Carlo feasibility study
    Min, Chul Hee
    Park, Jang Guen
    Kim, Chan Hyeong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2008, 52 (03) : 888 - 891
  • [34] Current State of Agonist Radioligands for Imaging of Brain Dopamine D2/D3 Receptors In Vivo with Positron Emission Tomography
    Finnema, Sjoerd J.
    Bang-Andersen, Benny
    Wikstrom, Hakan V.
    Halldin, Christer
    CURRENT TOPICS IN MEDICINAL CHEMISTRY, 2010, 10 (15) : 1477 - 1498
  • [35] STIMULATED POSITRON EMISSION FOR 3-D TOMOGRAPHIC IMAGING AND BONE STUDIES .1. METHOD FEASIBILITY AND SYSTEM CONSIDERATIONS
    BENJAMIN, M
    MACOVSKI, A
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (02) : 113 - 124
  • [36] RELATION OF ANGINA-PECTORIS TO SEVERITY OF CORONARY-ARTERY DISEASE BY QUANTITATIVE ARTERIOGRAPHY AND BY 3-D POSITRON EMISSION TOMOGRAPHY - A CASE FOR SCREENING BY POSITRON IMAGING
    DEMER, LL
    GOULD, KL
    GOLDSTEIN, RA
    KIRKEEIDE, RL
    CIRCULATION, 1986, 74 (04) : 42 - 42
  • [37] Adaptive 3D noise level-guided restoration network for low-dose positron emission tomography imaging
    Li, Wenbo
    Huang, Zhenxing
    Zhou, Chao
    Zhang, Xu
    Fan, Wei
    Liang, Dong
    Hu, Zhanli
    INTERDISCIPLINARY MEDICINE, 2023, 1 (03):
  • [38] Design and performance evaluation of a slit-slat camera for 2D prompt gamma imaging in proton therapy monitoring: A Monte Carlo simulation study
    Malekzadeh, Etesam
    Rajabi, Hossein
    Tajik-Mansoury, Mohammad Ali
    Sabouri, Pouya
    Fiorina, Elisa
    Kalantari, Faraz
    MEDICAL PHYSICS, 2023, 50 (06) : 3701 - 3718
  • [39] 3D imaging of the elemental concentration associated with a malignant tumor in breast cancer using Neutron Stimulated Emission Computed Tomography: a Monte Carlo simulation study
    Araghian, N.
    Miri-Hakimabad, H.
    Rafat-Motavalli, L.
    RADIOPROTECTION, 2016, 51 (02) : 101 - 111
  • [40] 3D imaging using combined neutron-photon fan-beam tomography: A Monte Carlo study
    Hartman, J.
    Yazdanpanah, A. Pour
    Barzilov, A.
    Regentova, E.
    APPLIED RADIATION AND ISOTOPES, 2016, 111 : 110 - 116