Development of integrated prompt gamma imaging and positron emission tomography system for in vivo 3-D dose verification: a Monte Carlo study

被引:14
|
作者
Choi, Hyun Joon [1 ]
Jang, Ji Won [1 ]
Shin, Wook-Geun [1 ]
Park, Hyojun [1 ]
Incerti, Sebastien [2 ,3 ]
Min, Chul Hee [1 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju 26493, South Korea
[2] Bordeaux Univ, UMR 5797, F-33170 Gradignan, France
[3] CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 10期
基金
新加坡国家研究基金会;
关键词
proton therapy; prompt gamma imaging; positron emission tomography; in vivo dose verification; Monte Carlo; CONVOLUTIONAL NEURAL-NETWORK; RANGE VERIFICATION; PROTON-BEAMS; THERAPY; PATIENT; CT; SEGMENTATION; VALIDATION; PREDICTION;
D O I
10.1088/1361-6560/ab857c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate knowledge of in vivo proton dose distribution is key to fully utilizing the potential advantages of proton therapy. Two representative indirect methods for in vivo range verification, namely, prompt gamma (PG) imaging and positron emission tomography (PET), are available. This study proposes a PG-PET system that combines the advantages of these two methods and presents detector geometry and background reduction techniques optimized for the PG-PET system. The characteristics of the secondary radiations emitted by a water phantom by interaction with a 150 MeV proton beam were analysed using Geant4.10.00, and the 2-D PG distributions were obtained and assessed for different detector geometries. In addition, the energy window (EW), depth-of-interaction (DOI), and time-of-flight (TOF) techniques are proposed as the background reduction techniques. To evaluate the performance of the PG-PET system, the 3-D dose distribution in the water phantom caused by two proton beams of energies 80 MeV and 100 MeV was verified using 16 optimal detectors. The thickness of the parallel-hole tungsten collimator of pitch 8 mm and width 7 mm was determined as 200 mm, and that of the GAGG scintillator was determined as 30 mm, by an optimization study. Further, 3-7 MeV and 2-7 MeV were obtained as the optimal EWs when the DOI and both the DOI and TOF techniques were applied for data processing, respectively; the detector performances were improved by about 38% and 167%, respectively, compared with that when applying only the 3-5 MeV EW. In this study, we confirmed that the PG distribution can be obtained by simply combining the 2-D parallel hole collimator and the PET detector module. In the future, we will develop an accurate 3-D dose evaluation technique using deep learning algorithms based on the image sets of dose, PG, and PET distributions for various proton energies.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] TWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDY
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 11 - 15
  • [2] Removal of the effect of compton scattering in 3-D whole body positron emission tomography by Monte Carlo
    Levin, CS
    Tai, YC
    Hoffman, EJ
    Dahlbom, M
    Farquhar, TH
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1050 - 1054
  • [3] Prompt gamma ray imaging for verification of proton boron fusion therapy: A Monte Carlo study
    Shin, Han-Back
    Yoon, Do-Kun
    Jung, Joo-Young
    Kim, Moo-Sub
    Suh, Tae Suk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1271 - 1275
  • [4] Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy
    Cheon, Bo-Wi
    Lee, Hyun Cheol
    You, Sei Hwan
    Seo, Hee
    Min, Chul Hee
    Choi, Hyun Joon
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (06) : 2018 - 2025
  • [5] Quantum Entanglement Filtering: A PET Feasibility Study in Imaging Dual-Positron and Prompt Gamma Emission via Monte Carlo Simulation
    Romanchek, Gregory
    Shoop, Greyson
    Gholami, Kimia
    Enlow, Emily
    Abbaszadeh, Shiva
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (08) : 916 - 925
  • [6] Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1063 - 1082
  • [7] Simulation Study of a 3-D Multislit Prompt Gamma Imaging System for Proton Therapy Monitoring
    Lu, Wenzhuo
    Zhang, Debin
    Fan, Peng
    Wang, Shi
    Wu, Zhaoxia
    Ma, Tianyu
    Liu, Yaqiang
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (03) : 355 - 365
  • [8] Development of a noncontact 3-D fluorescence tomography system for small animal in vivo imaging
    Zhang, Xiaofeng
    Badea, Cristian
    Jacob, Mathews
    Johnson, G. Allan
    FLUORESCENCE IN VIVO IMAGING BASED ON GENETICALLY ENGINEERED PROBES: FROM LIVING CELLS TO WHOLE BODY IMAGING IV, 2009, 7191
  • [9] A 3-D Lagrangian (Monte carlo) method for direct plume gamma dose rate calculations
    Raza, SS
    Avila, R
    Cervantes, J
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2001, 38 (04) : 254 - 260
  • [10] A 3-D Monte Carlo simulation of a small animal Positron Emission Tomograph with millimeter spatial resolution
    Bevilacqua, A
    Bollini, D
    Del Guerra, A
    Di Domenico, G
    Galli, M
    Scandola, M
    Zavattini, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 697 - 701