Comparison of Dental Surface Image Registration and Fiducial Marker Registration: An In Vivo Accuracy Study of Static Computer-Assisted Implant Surgery

被引:16
|
作者
Han, Yen-Ting [1 ]
Lin, Wei-Chun [2 ]
Fan, Fang-Yu [2 ]
Chen, Chih-Long [1 ]
Lin, Chia-Cheng [1 ,2 ]
Cheng, Hsin-Chung [3 ,4 ]
机构
[1] Shin Kong Wu Ho Mem Hosp, Dept Dent, Taipei 111, Taiwan
[2] Taipei Med Univ, Coll Oral Med, Sch Dent Technol, Taipei 110, Taiwan
[3] Taipei Med Univ, Coll Oral Med, Sch Dent, Taipei 110, Taiwan
[4] Taipei Med Univ Hosp, Dept Dent, Taipei 110, Taiwan
关键词
computer-assisted implant surgery; digital flow in dental surgery; accuracy; CT model registration; clinical research; STEREOLITHOGRAPHIC SURGICAL GUIDES; TECHNOLOGY APPLICATIONS; PLACEMENT; TOMOGRAPHY; DENTISTRY; TISSUE;
D O I
10.3390/jcm10184183
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared the accuracy of static computer-assisted implant surgery (sCAIS) planned through dental surface image registration and fiducial marker registration. Stone models of 30 patients were converted into digital dental casts by using a desktop scanner. Cone-beam computed tomography (CBCT) was performed and superimposed to the digital dental casts with two methods: matching the dental surface images or matching the fiducial markers on a stereolithographic radiographic template. Following the implant planning, stereolithographic surgical guides were fabricated, and 56 fully guided implants were inserted by the same doctor. Deviations between planned and inserted implants were measured and compared using postoperative CBCT images. After adjustment for other potential influencing factors, compared with the fiducial marker registration group, significantly larger mean lateral deviations were noted in the dental surface registration group at both the implant platform and apex (p = 0.0188 and 0.0371, respectively). However, the mean lateral deviations for the dental surface registration (0.83 +/- 0.51 mm at implant platform and 1.24 +/- 0.68 mm at implant apex) were comparable to the literature. In conclusion, our findings indicate that although sCAIS planned using dental surface image registration was not statistically as accurate as that using fiducial marker registration, its accuracy was satisfactory for clinical use.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non- randomized prospective study
    Jaemsuwan, S.
    Arunjaroensuk, S.
    Kaboosaya, B.
    Subbalekha, K.
    Mattheos, N.
    Pimkhaokham, A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (02) : 264 - 271
  • [42] A parallel implementation of 2-D/3-D image registration for computer-assisted surgery
    Ino, F
    Kawasaki, Y
    Tashiro, T
    Nakajima, Y
    Sato, Y
    Tamura, S
    Hagihara, K
    [J]. 11TH INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED SYSTEMS WORKSHOPS, VOL II, PROCEEDINGS,, 2005, : 316 - 320
  • [43] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Feng, Yuzhang
    Su, Zhenya
    Mo, Anchun
    Yang, Xingmei
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2022, 8 (01)
  • [44] Comparison of the accuracy of immediate implant placement using static and dynamic computer-assisted implant system in the esthetic zone of the maxilla: a prospective study
    Yuzhang Feng
    Zhenya Su
    Anchun Mo
    Xingmei Yang
    [J]. International Journal of Implant Dentistry, 8
  • [45] Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
    Ruiz-Romero, Victor
    Jorba-Garcia, Adria
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    [J]. JOURNAL OF DENTISTRY, 2024, 149
  • [46] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024,
  • [47] The impact of cone beam computer tomography field of view on the precision of digital intra-oral scan registration for static computer-assisted implant surgery: A CBCT analysis
    Hamilton, Adam
    Singh, Ashi
    Friedland, Bernard
    Jamjoom, Faris Z.
    Griseto, Neil
    Gallucci, German O.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (12) : 1273 - 1281
  • [48] Accurate and robust registration method for computer-assisted high tibial osteotomy surgery
    Chuanba Liu
    Yimin Song
    Xinlong Ma
    Tao Sun
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 329 - 337
  • [49] Accurate and robust registration method for computer-assisted high tibial osteotomy surgery
    Liu, Chuanba
    Song, Yimin
    Ma, Xinlong
    Sun, Tao
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (02) : 329 - 337
  • [50] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853