Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study

被引:0
|
作者
Li, Ping [1 ,2 ,3 ]
Zhao, Chunhui [1 ,2 ]
Chen, Jiahao [4 ]
Xu, Shulan [3 ]
Yang, Shuo [3 ]
Li, An [5 ]
机构
[1] Guangzhou Med Univ, Sch & Hosp Stomatol, Guangdong Engn Res Ctr Oral Restorat & Reconstruct, Dept Prosthodont, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Guangzhou, Peoples R China
[3] Southern Med Univ, Stomatol Hosp, Ctr Oral Implantol, Sch Stomatol, Guangzhou, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Guangzhou, Peoples R China
[5] Southern Med Univ, Stomatol Hosp, Sch Stomatol, Dept Periodontol, Guangzhou 510280, Peoples R China
关键词
accuracy; computer-assisted surgery; dental implants; immediate implant placement; robot-assisted surgery; TECHNOLOGY APPLICATIONS; EXTRACTION; NAVIGATION; DENTISTRY;
D O I
10.1111/cid.13383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives:This study investigated the accuracy of robotic computer-assistedimplant surgery (r-CAIS) for immediate implant placement.Methods:Twenty cases with 20 implant sites were selected based on predefinedinclusion criteria. The preparation of the implant bed and implant placement followedthe standardized dental implant robotic surgery protocol. Postoperative cone-beamcomputed tomography scans were conducted to assess possible discrepanciesbetween actual and planned implant positions.Results:The r-CAIS technology for immediate implant placement exhibited a meanglobal coronal deviation of 0.71 +/- 0.27 mm (95% CI: 0.58-0.83 mm), a mean globalapical deviation of 0.69 +/- 0.26 mm (95% CI: 0.56-0.81 mm), and an angular deviationof 1.27 +/- 0.47 degrees(95% CI: 1.05-1.49 degrees). A substantial number of deviations wereobserved buccally at both coronal (90%) and apical (95%) levels, with a consistenttendency for buccal deviation.Conclusions:The r-CAIS technology proved a promising approach for immediateimplantation in the anterior region, with satisfactory clinical outcomes. However, anoptimized surgical protocol for r-CAIS technology is required for particular implantsites like extraction sockets or bone defects
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [1] Accuracy of robotic-assisted surgery for immediate implant placement in posterior teeth: a retrospective case series
    Tao Yang
    Wenan Xu
    Xiaojian Xing
    Fengzhou Li
    Shuo Yang
    Buling Wu
    BMC Oral Health, 24 (1)
  • [2] Accuracy analysis of robotic-assisted immediate implant placement: A retrospective case series
    Zhao, Ningbo
    Du, Liangzhi
    Lv, Chengpeng
    Liang, Jianfei
    He, Longlong
    Zhou, Qin
    JOURNAL OF DENTISTRY, 2024, 146
  • [3] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229
  • [4] Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study
    Li, Jun
    Dai, Meng
    Wang, Siwei
    Zhang, Xitao
    Fan, Qin
    Chen, Lin
    JOURNAL OF DENTISTRY, 2024, 148
  • [5] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [6] Accuracy of computer-assisted implant placement with insertion templates
    Naziri, Eleni
    Schramm, Alexander
    Wilde, Frank
    GMS INTERDISCIPLINARY PLASTIC AND RECONSTRUCTIVE SURGERY DGPW, 2016, 5
  • [7] Accuracy of flapless immediate implant placement in anterior maxilla using computer-assisted versus freehand surgery: A cadaver study
    Chen, Zhaozhao
    Li, Junying
    Sinjab, Khaled
    Mendonca, Gustavo
    Yu, Haiyang
    Wang, Hom-Lay
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (12) : 1186 - 1194
  • [8] Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (05) : 608 - 618
  • [9] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23
  • [10] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)