Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study

被引:1
|
作者
Li, Ping [1 ,2 ,3 ]
Zhao, Chunhui [1 ,2 ]
Chen, Jiahao [4 ]
Xu, Shulan [3 ]
Yang, Shuo [3 ]
Li, An [5 ]
机构
[1] Guangzhou Med Univ, Sch & Hosp Stomatol, Guangdong Engn Res Ctr Oral Restorat & Reconstruct, Dept Prosthodont, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Guangzhou, Peoples R China
[3] Southern Med Univ, Stomatol Hosp, Ctr Oral Implantol, Sch Stomatol, Guangzhou, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Guangzhou, Peoples R China
[5] Southern Med Univ, Stomatol Hosp, Sch Stomatol, Dept Periodontol, Guangzhou 510280, Peoples R China
关键词
accuracy; computer-assisted surgery; dental implants; immediate implant placement; robot-assisted surgery; TECHNOLOGY APPLICATIONS; EXTRACTION; NAVIGATION; DENTISTRY;
D O I
10.1111/cid.13383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives:This study investigated the accuracy of robotic computer-assistedimplant surgery (r-CAIS) for immediate implant placement.Methods:Twenty cases with 20 implant sites were selected based on predefinedinclusion criteria. The preparation of the implant bed and implant placement followedthe standardized dental implant robotic surgery protocol. Postoperative cone-beamcomputed tomography scans were conducted to assess possible discrepanciesbetween actual and planned implant positions.Results:The r-CAIS technology for immediate implant placement exhibited a meanglobal coronal deviation of 0.71 +/- 0.27 mm (95% CI: 0.58-0.83 mm), a mean globalapical deviation of 0.69 +/- 0.26 mm (95% CI: 0.56-0.81 mm), and an angular deviationof 1.27 +/- 0.47 degrees(95% CI: 1.05-1.49 degrees). A substantial number of deviations wereobserved buccally at both coronal (90%) and apical (95%) levels, with a consistenttendency for buccal deviation.Conclusions:The r-CAIS technology proved a promising approach for immediateimplantation in the anterior region, with satisfactory clinical outcomes. However, anoptimized surgical protocol for r-CAIS technology is required for particular implantsites like extraction sockets or bone defects
引用
收藏
页码:1279 / 1288
页数:10
相关论文
共 50 条
  • [21] Papilla Formation in Response to Computer-Assisted Implant Surgery and Immediate Restoration
    Schnitman, Paul A.
    Hayashi, Chie
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (04) : 459 - 466
  • [22] Comparison of the accuracy of implant placement using different drilling systems for static computer-assisted implant surgery: A simulation-based experimental study
    Sittikornpaiboon, Paknisa
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (04) : 635 - 643
  • [23] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853
  • [24] The Accuracy of Dental Implant Placement With Different Methods of Computer-Assisted Implant Surgery: A Network Meta-Analysis of Clinical Studies
    Mahardawi, Basel
    Jiaranuchart, Sirimanas
    Arunjaroensuk, Sirida
    Dhanesuan, Kanit
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 1 - 16
  • [25] Transitional implants in computer-assisted implant surgery and fixed complete-arch provisionalization: A retrospective case series
    Pedrinaci, Ignacio
    Ben Dor, Betty
    Rousson, Dominique
    Lanis, Alejandro
    Sanz-Esporrin, Javier
    Pala, Kevser
    Gallucci, German O.
    Hamilton, Adam
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2025, 27 (01)
  • [26] Accuracy of a novel semi-autonomous robotic-assisted surgery system for single implant placement: A case series
    Ding, Yude
    Zheng, Yuxin
    Chen, Runzhi
    Cao, Ruijue
    Chen, Jianping
    Wang, Linhong
    Yang, Fan
    JOURNAL OF DENTISTRY, 2023, 139
  • [27] Influence of implant macrodesign and insertion connection technology on the accuracy of static computer-assisted implant surgery
    El Kholy, Karim
    Ebenezer, Supriya
    Wittneben, Julia-Gabriela
    Lazarin, Rafael
    Rousson, Dominique
    Buser, Daniel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 1073 - 1079
  • [28] The Impact of Surgical Guide Fixation and Implant Location on Accuracy of Static Computer-Assisted Implant Surgery
    Pessoa, Roberto
    Siqueira, Rafael
    Li, Junying
    Saleh, Islam
    Meneghetti, Priscila
    Bezerra, Fabio
    Wang, Hom-Lay
    Mendonca, Gustavo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02): : 155 - 164
  • [29] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Ku, Jeong-Kui
    Lee, Junggon
    Lee, Hyo-Jung
    Yun, Pil-Young
    Kim, Young-Kyun
    BMC ORAL HEALTH, 2022, 22 (01)
  • [30] Accuracy of dental implant placement with computer-guided surgery: a retrospective cohort study
    Jeong-Kui Ku
    Junggon Lee
    Hyo-Jung Lee
    Pil-Young Yun
    Young-Kyun Kim
    BMC Oral Health, 22