Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study

被引:0
|
作者
Li, Ping [1 ,2 ,3 ]
Zhao, Chunhui [1 ,2 ]
Chen, Jiahao [4 ]
Xu, Shulan [3 ]
Yang, Shuo [3 ]
Li, An [5 ]
机构
[1] Guangzhou Med Univ, Sch & Hosp Stomatol, Guangdong Engn Res Ctr Oral Restorat & Reconstruct, Dept Prosthodont, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Guangzhou, Peoples R China
[3] Southern Med Univ, Stomatol Hosp, Ctr Oral Implantol, Sch Stomatol, Guangzhou, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Guangzhou, Peoples R China
[5] Southern Med Univ, Stomatol Hosp, Sch Stomatol, Dept Periodontol, Guangzhou 510280, Peoples R China
关键词
accuracy; computer-assisted surgery; dental implants; immediate implant placement; robot-assisted surgery; TECHNOLOGY APPLICATIONS; EXTRACTION; NAVIGATION; DENTISTRY;
D O I
10.1111/cid.13383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives:This study investigated the accuracy of robotic computer-assistedimplant surgery (r-CAIS) for immediate implant placement.Methods:Twenty cases with 20 implant sites were selected based on predefinedinclusion criteria. The preparation of the implant bed and implant placement followedthe standardized dental implant robotic surgery protocol. Postoperative cone-beamcomputed tomography scans were conducted to assess possible discrepanciesbetween actual and planned implant positions.Results:The r-CAIS technology for immediate implant placement exhibited a meanglobal coronal deviation of 0.71 +/- 0.27 mm (95% CI: 0.58-0.83 mm), a mean globalapical deviation of 0.69 +/- 0.26 mm (95% CI: 0.56-0.81 mm), and an angular deviationof 1.27 +/- 0.47 degrees(95% CI: 1.05-1.49 degrees). A substantial number of deviations wereobserved buccally at both coronal (90%) and apical (95%) levels, with a consistenttendency for buccal deviation.Conclusions:The r-CAIS technology proved a promising approach for immediateimplantation in the anterior region, with satisfactory clinical outcomes. However, anoptimized surgical protocol for r-CAIS technology is required for particular implantsites like extraction sockets or bone defects
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [41] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348
  • [42] Accuracy of Different Surgical Guide Designs for Static Computer-Assisted Implant Surgery: An In Vitro Study
    Wu, Yu Tsung
    Papaspyridakos, Panos
    Kang, Kiho
    Finkelman, Matthew
    Kudara, Yukio
    De Souza, Andre B.
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (05) : 351 - 357
  • [43] Evaluation of accuracy and membrane perforation in robotic-assisted implant surgery for transalveolar sinus floor elevation: a retrospective case series
    Tao Yang
    Wenjing Yi
    Wenan Xu
    Xiaojian Xing
    Buling Wu
    BMC Oral Health, 25 (1)
  • [44] Immediate Implant Placement in Infected Sites: A Case Series
    Marconcini, Simone
    Barone, Antonio
    Gelpi, Federico
    Briguglio, Francesco
    Covani, Ugo
    JOURNAL OF PERIODONTOLOGY, 2013, 84 (02) : 196 - 202
  • [45] Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study
    Fu, Shuang
    Sun, Wei
    Zhu, Jingxian
    Huang, Bin
    Ji, Wei
    Shi, Bin
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (09) : 5427 - 5438
  • [46] Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study
    Shuang Fu
    Wei Sun
    Jingxian Zhu
    Bin Huang
    Wei Ji
    Bin Shi
    Clinical Oral Investigations, 2023, 27 : 5427 - 5438
  • [47] Influence of dental implant clinical experience on the accuracy of robot-assisted immediate implant placement: an in vitro study
    Wang, Yunxiao
    Wang, Yulan
    Yu, Shimin
    Han, Litian
    Feng, Yi
    Miron, Richard J.
    Yan, Qi
    Zhang, Yufeng
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (09)
  • [48] Computer-assisted flapless implant placement reduces the incidence of surgery-related bacteremia
    Volkan Arısan
    Nilüfer Bölükbaşı
    Lütfiye Öksüz
    Clinical Oral Investigations, 2013, 17 : 1985 - 1993
  • [49] Computer-assisted flapless implant placement reduces the incidence of surgery-related bacteremia
    Arisan, Volkan
    Bolukbasi, Nilufer
    Oksuz, Lutfiye
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 1985 - 1993
  • [50] Accuracy of the Yakebot dental implant robotic system versus fully guided static computer-assisted implant surgery template in edentulous jaw implantation: A preliminary clinical study
    Wang, Wenxue
    Xu, Hao
    Mei, Dongmei
    Zhou, Chen
    Li, Xiaojing
    Han, Ze'yu
    Zhou, Xiaobin
    Li, Xin
    Zhao, Baodong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 309 - 316