Accuracy of Different Surgical Guide Designs for Static Computer-Assisted Implant Surgery: An In Vitro Study

被引:4
|
作者
Wu, Yu Tsung [1 ]
Papaspyridakos, Panos [1 ]
Kang, Kiho [1 ]
Finkelman, Matthew [2 ]
Kudara, Yukio
De Souza, Andre B. [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
[2] Tufts Univ, Sch Dent Med, Dept Publ Hlth & Community Serv, Boston, MA USA
关键词
dental implants; digital workflow; guided implant surgery; accuracy; computer-aided; computed-manufactured; TECHNOLOGY APPLICATIONS; DENTAL PROSTHESES; COMPLICATIONS; DENTISTRY; PRECISION; SURVIVAL; RATES;
D O I
10.1563/aaid-joi-D-21-00055
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aims of this study were to evaluate the effect of (1) the different surgical guide designs and (2) implant placement location on the accuracy of fully guided implant placement in single edentulous sites using an in vitro study model. Forty-five partially edentulous models were scanned and divided into 3 groups: group 1, tooth-supported full-arch surgical guide; group 2, 3 different tooth-supported shortened surgical guides (SSGs); and group 3, tooth-supported full-arch surgical guide with a crossbar. All surgical guides were printed and used for fully guided implant placement. A total of 180 implants (60 per group) were placed, and scan bodies were positioned on all models, and postoperative surface scan files (STL) files were obtained. Superimposition of preoperative and postoperative STL files was performed, and the accuracy of implant position was evaluated. The interaction between group and implant location was statistically significant for angle, 3D offset at the base, and at the tip (P < .001). The post-hoc tests showed a statistically significantly higher deviation for group 2 compared to group 3 for all outcomes for implants #4 (P < .05) and #7 (P < .05). There was also a statistically significant difference in all outcomes between groups 1 and 3 for implant #7 (P < .05). All surgical guide designs presented satisfactory performance with clinically acceptable levels of deviation. However, SSGs presented higher accuracy for guided implant placement in a single -edentulous site, whereas a full-arch surgical guide with a crossbar presented superior outcomes when 2 or more guided implants were placed simultaneously.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [1] The Impact of Surgical Guide Fixation and Implant Location on Accuracy of Static Computer-Assisted Implant Surgery
    Pessoa, Roberto
    Siqueira, Rafael
    Li, Junying
    Saleh, Islam
    Meneghetti, Priscila
    Bezerra, Fabio
    Wang, Hom-Lay
    Mendonca, Gustavo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (02): : 155 - 164
  • [2] A comparative retrospective study of different surgical guide designs for static computer-assisted implant surgery in posterior single edentulous sites
    De Souza, Andre Barbisan
    Kang, Michael
    Negreiros, William Matthew
    El-Rafie, Khaled
    Finkelman, Matthew
    Papaspyridakos, Panos
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (01) : 45 - 52
  • [3] Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery
    El Kholy, Karim
    Lazarin, Rafael
    Janner, Simone F. M.
    Faerber, Karin
    Buser, Ramona
    Buser, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (11) : 1067 - 1075
  • [4] Influence of alveolar ridge morphology and guide-hole design on the accuracy of static Computer-Assisted Implant Surgery with two implant macro-designs: An in vitro study
    Dulla, Fabrice Alain
    Couso-Queiruga, Emilio
    Chappuis, Vivianne
    Yilmaz, Burak
    Abou-Ayash, Samir
    Raabe, Clemens
    JOURNAL OF DENTISTRY, 2023, 130
  • [5] Evaluation of the Accuracy, Surgical Time, and Learning Curve of Freehand, Static, and Dynamic Computer-Assisted Implant Surgery in an In Vitro Study
    Werny, Joscha Gabriel
    Fan, Shengchi
    Diaz, Leonardo
    Al-Nawas, Bilal
    Sagheb, Keyvan
    Gielisch, Matthias
    Schiegnitz, Eik
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [6] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [7] In Vivo and In Vitro Accuracy Analysis of Static Computer-Assisted Implant Surgery in an Edentulous Patient
    Makarov, Nikolay
    Papi, Piero
    Santomauro, Vincenzo
    Di Carlo, Gabriele
    Polimeni, Antonella
    Di Murro, Bianca
    Saccucci, Matteo
    APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [8] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Raabe, Clemens
    Schuetz, Tabea S.
    Chappuis, Vivianne
    Yilmaz, Burak
    Abou-Ayash, Samir
    Couso-Queiruga, Emilio
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01) : 4
  • [9] Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study
    Clemens Raabe
    Tabea S. Schuetz
    Vivianne Chappuis
    Burak Yilmaz
    Samir Abou-Ayash
    Emilio Couso-Queiruga
    International Journal of Implant Dentistry, 9
  • [10] Influence of template design on the accuracy of static computer-assisted implant surgery
    Chung, Jinmook
    Park, Junghyun
    Son, Hyeonseong
    Hong, Seoung-Jin
    Pae, Ahran
    JOURNAL OF ADVANCED PROSTHODONTICS, 2025, 17 (01): : 22 - 35