Accuracy of Different Surgical Guide Designs for Static Computer-Assisted Implant Surgery: An In Vitro Study

被引:4
|
作者
Wu, Yu Tsung [1 ]
Papaspyridakos, Panos [1 ]
Kang, Kiho [1 ]
Finkelman, Matthew [2 ]
Kudara, Yukio
De Souza, Andre B. [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
[2] Tufts Univ, Sch Dent Med, Dept Publ Hlth & Community Serv, Boston, MA USA
关键词
dental implants; digital workflow; guided implant surgery; accuracy; computer-aided; computed-manufactured; TECHNOLOGY APPLICATIONS; DENTAL PROSTHESES; COMPLICATIONS; DENTISTRY; PRECISION; SURVIVAL; RATES;
D O I
10.1563/aaid-joi-D-21-00055
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aims of this study were to evaluate the effect of (1) the different surgical guide designs and (2) implant placement location on the accuracy of fully guided implant placement in single edentulous sites using an in vitro study model. Forty-five partially edentulous models were scanned and divided into 3 groups: group 1, tooth-supported full-arch surgical guide; group 2, 3 different tooth-supported shortened surgical guides (SSGs); and group 3, tooth-supported full-arch surgical guide with a crossbar. All surgical guides were printed and used for fully guided implant placement. A total of 180 implants (60 per group) were placed, and scan bodies were positioned on all models, and postoperative surface scan files (STL) files were obtained. Superimposition of preoperative and postoperative STL files was performed, and the accuracy of implant position was evaluated. The interaction between group and implant location was statistically significant for angle, 3D offset at the base, and at the tip (P < .001). The post-hoc tests showed a statistically significantly higher deviation for group 2 compared to group 3 for all outcomes for implants #4 (P < .05) and #7 (P < .05). There was also a statistically significant difference in all outcomes between groups 1 and 3 for implant #7 (P < .05). All surgical guide designs presented satisfactory performance with clinically acceptable levels of deviation. However, SSGs presented higher accuracy for guided implant placement in a single -edentulous site, whereas a full-arch surgical guide with a crossbar presented superior outcomes when 2 or more guided implants were placed simultaneously.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [21] Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study
    Li, Jun
    Dai, Meng
    Wang, Siwei
    Zhang, Xitao
    Fan, Qin
    Chen, Lin
    JOURNAL OF DENTISTRY, 2024, 148
  • [22] Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study
    Toyoshima, Takeshi
    Tanaka, Hideaki
    Sasaki, Masanori
    Ichimaru, Eiji
    Naito, Yasushi
    Matsushita, Yasuyuki
    Koyano, Kiyoshi
    Nakamura, Seiji
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2015, 1 (01): : 10 - 17
  • [23] Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (05) : 608 - 618
  • [24] Is there a learning curve in static computer-assisted implant surgery? A prospective clinical study
    Cassetta, M.
    Altieri, F.
    Giansanti, M.
    Bellardini, M.
    Brandetti, G.
    Piccoli, L.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (10) : 1335 - 1342
  • [25] Influence of drilling sequence and guide-hole design on the accuracy of static computer-assisted implant surgery in extraction sockets and healed sites-An in vitro investigation
    Raabe, Clemens
    Dulla, Fabrice Alain
    Yilmaz, Burak
    Chappuis, Vivianne
    Abou-Ayash, Samir
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (04) : 320 - 329
  • [26] Bead-anchored surgical templates for static computer-assisted implant surgery: A dental technique
    Orgev, Ahmet
    Pellerito, John
    Polido, Waldemar
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (08): : 722 - 727
  • [27] Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study
    Shusterman, Ariel
    Nashef, Rizan
    Tecco, Simona
    Mangano, Carlo
    Lerner, Henriette
    Mangano, Francesco Guido
    JOURNAL OF DENTISTRY, 2024, 146
  • [28] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288
  • [29] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853
  • [30] Comparison of Dental Surface Image Registration and Fiducial Marker Registration: An In Vivo Accuracy Study of Static Computer-Assisted Implant Surgery
    Han, Yen-Ting
    Lin, Wei-Chun
    Fan, Fang-Yu
    Chen, Chih-Long
    Lin, Chia-Cheng
    Cheng, Hsin-Chung
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)