Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study

被引:0
|
作者
Ruiz-Romero, Victor [1 ]
Jorba-Garcia, Adria [1 ]
Camps-Font, Octavi [2 ,3 ]
Figueiredo, Rui [2 ,3 ]
Valmaseda-Castellon, Eduard [2 ,3 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg & Implantol, Barcelona, Spain
[2] Univ Barcelona, Fac Med & Hlth Sci, Oral Surg, Barcelona, Spain
[3] IDIBELL Inst, Barcelona, Spain
关键词
Computer-assisted surgery; Dental Implants; Surgical navigation systems; Edentulous jaw; Implant-supported dental prosthesis; Dimensional measurement accuracy; COMPLETE DENTAL PROSTHESES; SURVIVAL RATES; NAVIGATION; PLACEMENT; COMPLICATIONS;
D O I
10.1016/j.jdent.2024.105290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare miniscrew versus bone tracing registration methods on dental implant placement accuracy and time efficiency in edentulous jaws using a dynamic computer-assisted implant surgery (d-CAIS) system. Methods: Twelve fully edentulous maxillary models were allocated into two groups: miniscrew tracing (MST) group, where registration was performed by tracing four miniscrews; and bone tracing (BT) group, where registration was conducted by tracing maxillary bone fiducial landmarks. Six implants were placed on each model using the X-Guide (R) d-CAIS system. Pre- and postoperative cone-beam computed tomography (CBCT) scans were superimposed to evaluate implant placement accuracy. The time required for registration and the overall surgery time were also recorded. Results: Thirty-six implants were placed in each group. The MST group showed significantly lower mean angulation deviations (mean difference (MD): -3.33 degrees; 95 % confidence interval (CI): -6.56 to -0.09); p = 0.044), 3D platform deviations (MD: -1.01 mm; 95 % CI: -1.74 to -0.29; p = 0.006), 2D platform deviations (MD: -0.97 mm; 95 % CI: -1.71 to -0.23; p = 0.010), and 3D apex deviations (MD: -1.18 mm; 95 % CI: -1.92 to -0.44; p = 0.002) versus the BT group. The overall surgery time was similar for both groups (MD: 6.10 min.; 95 % CI: -0.31 to 12.51; p = 0.06), though bone tracing required significantly more time compared with miniscrew registration (MD: 4.79 min.; 95 % CI: 2.96 to 6.62; p < 0.05). Conclusions: Registration with MST increases the accuracy of implant placement with a d-CAIS system in edentulous jaws compared with the BT method, and slightly reduces the overall surgery time.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] In Vivo and In Vitro Accuracy Analysis of Static Computer-Assisted Implant Surgery in an Edentulous Patient
    Makarov, Nikolay
    Papi, Piero
    Santomauro, Vincenzo
    Di Carlo, Gabriele
    Polimeni, Antonella
    Di Murro, Bianca
    Saccucci, Matteo
    [J]. APPLIED SCIENCES-BASEL, 2023, 13 (02):
  • [2] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853
  • [3] Comparison of the accuracy of implant position among freehand implant placement, static and dynamic computer-assisted implant surgery in fully edentulous patients: a non- randomized prospective study
    Jaemsuwan, S.
    Arunjaroensuk, S.
    Kaboosaya, B.
    Subbalekha, K.
    Mattheos, N.
    Pimkhaokham, A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2023, 52 (02) : 264 - 271
  • [4] The accuracy of dynamic computer assisted implant surgery in fully edentulous jaws: A retrospective case series
    Wang, Jiayi
    Ge, Yanjun
    Muhlemann, Sven
    Pan, Shaoxia
    Jung, Ronald E.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (11) : 1278 - 1288
  • [5] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    [J]. JOURNAL OF DENTISTRY, 2023, 132
  • [6] Dynamic and static computer-assisted implant surgery for completely edentulous patients. A proof of a concept
    Pomares-Puig, Carmen
    Sanchez-Garces, M. Angeles
    Jorba-Garcia, Adria
    [J]. JOURNAL OF DENTISTRY, 2023, 130
  • [7] Does a fully digital workflow improve the accuracy of computer-assisted implant surgery in partially edentulous patients? A systematic review of clinical trials
    Siqueira, Rafael
    Chen, Zhaozhao
    Galli, Matthew
    Saleh, Islam
    Wang, Hom-Lay
    Chan, Hsun-Liang
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (06) : 660 - 671
  • [8] Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study
    Shuang Fu
    Wei Sun
    Jingxian Zhu
    Bin Huang
    Wei Ji
    Bin Shi
    [J]. Clinical Oral Investigations, 2023, 27 : 5427 - 5438
  • [9] Accuracy and patient-centered results of static and dynamic computer-assisted implant surgery in edentulous jaws: a retrospective cohort study
    Fu, Shuang
    Sun, Wei
    Zhu, Jingxian
    Huang, Bin
    Ji, Wei
    Shi, Bin
    [J]. CLINICAL ORAL INVESTIGATIONS, 2023, 27 (09) : 5427 - 5438
  • [10] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401