Improved Demagnetization Control of a Doubly-Fed Induction Generator Under Balanced Grid Fault

被引:61
|
作者
Zhou, Linyuan [1 ]
Liu, Jinjun [1 ]
Zhou, Sizhan [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Demagnetization control; doubly-fed induction generator (DFIG); low-voltage ride-through (LVRT); DFIG WIND TURBINE; RIDE-THROUGH; VOLTAGE DIPS; CAPABILITY; SYSTEM; POWER;
D O I
10.1109/TPEL.2014.2382603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Doubly-fed induction generators are one of the most popular machines for variable-speed wind turbine. However, they are very sensitive to grid fault since the stator is directly connected to the grid. This paper analyzes the low-voltage ride-through performance of a doubly-fed induction generator-based wind turbine under balanced grid fault. An improved demagnetization control, immune to system parameter variation, is proposed to shorten the dynamic process. The investigation shows that the proposed method increases the probability of a successful ride-through at the recovery moment of balanced grid fault. Feasibility region for a representatively sized system is also investigated for balanced grid fault. In order to verify the proposed control method, laboratory experiments are carried out and the results demonstrate the analysis.
引用
收藏
页码:6695 / 6705
页数:11
相关论文
共 50 条
  • [1] An Improved Grid Synchronization Control of Doubly-Fed Induction Generator
    Zhan, Liangyu
    Jin, Xinmin
    Zhang, Lu
    [J]. 2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [2] Control Strategy of Doubly-Fed Induction Generator under Zero Voltage Fault of Power Grid
    Ye, Yi
    Yang, Zelin
    Hu, Jiawei
    Yi, Haopeng
    Zhang, Lu
    [J]. SUSTAINABILITY, 2022, 14 (23)
  • [3] A Novel Grid Synchronization Control of Doubly-fed Induction Generator
    ZHAN Liang-yu
    [J]. 电力电子技术, 2012, 46 (04) : 38 - 42
  • [4] Thermal Behavior of Doubly-Fed Induction Generator Wind Turbine System during Balanced Grid Fault
    Zhou, Dao
    Blaabjerg, Frede
    Lau, Mogens
    Tonnes, Michael
    [J]. 2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 3076 - +
  • [5] Transient Responses of the Doubly-Fed Induction Generator Wind Turbine under Grid Fault Conditions
    Phan, T. T.
    Nguyen, V. L.
    Hossain, M. J.
    To, A. N.
    Tran, H. T.
    Phan, T. N.
    [J]. 2016 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING AND APPLICATIONS (ACOMP), 2016, : 97 - 104
  • [6] Grid Forming Stator Flux Control of Doubly-Fed Induction Generator
    Klaes, Norbert
    Poeschke, Florian
    Schulte, Horst
    [J]. ENERGIES, 2021, 14 (20)
  • [7] DOUBLY-FED INDUCTION GENERATOR CONTROL DURING UNBALANCED GRID CONDITIONS
    Mendes, Victor F.
    Pereira, Heverton
    Matos, Frederico F.
    Hofmann, Wilfried
    Silva, Selenio R.
    [J]. 2015 IEEE 13TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 1ST SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2015,
  • [8] Doubly-Fed Induction Generator Control Under Voltage Sags
    Lima, K.
    Luna, A.
    Rodriguez, P.
    Watanabe, E.
    Teodorescu, R.
    Blaabjerg, F.
    [J]. 2008 IEEE ENERGY 2030 CONFERENCE, 2008, : 511 - +
  • [9] Control method of a doubly-fed induction generator with automatic grid synchronization
    Park, Jungwoo
    Lee, Kiwook
    Kim, Dongwook
    [J]. IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 1093 - +
  • [10] Intelligent Control of Grid Connected Unified Doubly-Fed Induction Generator
    Singh, Bharat
    Kyriakides, Elias
    Singh, Sri Niwas
    [J]. IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,