Improved Demagnetization Control of a Doubly-Fed Induction Generator Under Balanced Grid Fault

被引:61
|
作者
Zhou, Linyuan [1 ]
Liu, Jinjun [1 ]
Zhou, Sizhan [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Demagnetization control; doubly-fed induction generator (DFIG); low-voltage ride-through (LVRT); DFIG WIND TURBINE; RIDE-THROUGH; VOLTAGE DIPS; CAPABILITY; SYSTEM; POWER;
D O I
10.1109/TPEL.2014.2382603
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Doubly-fed induction generators are one of the most popular machines for variable-speed wind turbine. However, they are very sensitive to grid fault since the stator is directly connected to the grid. This paper analyzes the low-voltage ride-through performance of a doubly-fed induction generator-based wind turbine under balanced grid fault. An improved demagnetization control, immune to system parameter variation, is proposed to shorten the dynamic process. The investigation shows that the proposed method increases the probability of a successful ride-through at the recovery moment of balanced grid fault. Feasibility region for a representatively sized system is also investigated for balanced grid fault. In order to verify the proposed control method, laboratory experiments are carried out and the results demonstrate the analysis.
引用
收藏
页码:6695 / 6705
页数:11
相关论文
共 50 条
  • [41] Grid-Flux-Oriented Control and Synchronization for a Doubly-Fed Induction Generator System
    Mueangngoen, Sutthimat
    Kumsuwan, Yuttana
    [J]. TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 1257 - 1262
  • [42] Transient Coordination Control Strategy of Grid-friendly Doubly-fed Induction Generator
    Zhang, Lei
    Zhang, Chuang
    Luo, Yi
    Yao, Liangzhong
    Qian, Minhui
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (12): : 44 - 50
  • [43] Control and Operation of Brushless Doubly-Fed Induction Generator under Unbalanced Network
    Xu, Litong
    Cheng, Ming
    Wei, Xinchi
    Zeng, Yu
    [J]. 2020 23RD INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2020, : 1184 - 1189
  • [44] Optimization Strategy of Virtual Synchronous Generator Control for Doubly-fed Induction Generator in Unbalanced Power Grid
    Sun, Jun
    Jiang, Tianlong
    Wang, Yangming
    Sun, Dan
    Ye, Shankun
    Duan, Hui
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (10): : 135 - 144
  • [45] Wind turbines with doubly-fed induction generator systems with improved performance due to grid requirements
    Ehlert, D.
    Wrede, H.
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3841 - 3847
  • [46] Grid disturbance response of wind turbines equipped with induction generator and doubly-fed induction generator
    Thiringer, T
    Petersson, A
    Petru, T
    [J]. 2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1542 - 1547
  • [47] Single Grid Connection of Doubly-Fed Induction Generator for Wind Turbines
    Han, Yongsu
    Lee, Wook-Jin
    Ha, Jung-Ik
    [J]. 2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,
  • [48] Virtual Transient Flux Linkage Control of Doubly Fed Induction Generator Under Symmetrical Grid Fault
    Lu, Shixin
    Liu, Guorong
    Hu, Shiyang
    Yang, Xiaoliang
    [J]. 10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 274 - 283
  • [49] Improved Vector Control for Stand-alone Brushless Doubly-Fed Induction Generator
    Yu, Kailiang
    Xu, Wei
    Liu, Yi
    Gao, Jianping
    [J]. IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 274 - 279
  • [50] Unbalanced fault diagnosis of rotor winding in doubly-fed induction generator
    Ma, Hong-Zhong
    Li, Si-Yuan
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2020, 24 (02): : 138 - 143