Permeability of gloves used in nuclear medicine departments to [99mTc]-pertechnetate and [18F]-fluorodeoxyglucose: Radiation protection considerations

被引:1
|
作者
Ridone, S. [1 ]
Matheoud, R. [1 ]
Valzano, S. [1 ]
Di Martino, R. [2 ]
Vigna, L. [1 ]
Brambilla, M. [1 ]
机构
[1] Univ Hosp Maggiore Della Carita Novara, Dept Med Phys, I-28100 Novara, Italy
[2] Univ Oriental Piedmont, Sch Med, I-28100 Novara, Italy
来源
关键词
Gloves; Permeability [(99)mTc]-pertechnetate; F-18]-FDG; Radiation protection; SKIN CONTAMINATION; RADIONUCLIDE;
D O I
10.1016/j.ejmp.2013.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In order to evaluate the safety of the individual protection devices, the permeability of four different types of disposable gloves, commonly used in hospitals, was tested in relation to [Tc-99m]-pertechnetate and to [F-18]-fluorodeoxyglucose ([F-18]-FDG). From these radiopharmaceutical solutions, a drop was deposited on the external surface of the glove which was opened and stretched with the external surface placed upward. The smear test technique permitted to evaluate the activity onto the inner surface of the glove at different times. The smear tests were measured in a well sodium iodide detector calibrated in efficiency for Tc-99m and F-18. The permeability was tested on ten samples of each type of gloves and was expressed as the ratio of the activity onto the inner surface at each time interval to the activity deposited on the external surface of the glove. For each type of gloves and for each sampling time, mean value, standard deviation and percentage coefficient of variation of permeability were evaluated. One type of gloves showed a low resistance to permeation of both radiopharmaceuticals, while another one only to pertechnetate. The other gloves were good performers. The results of this study suggest to test permeability for gloves used for handling radiopharmaceuticals, before their adoption in the clinical routine. This practice will provide a more careful service of radiation protection for nuclear medicine department staff. (C) 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:545 / 548
页数:4
相关论文
共 50 条
  • [41] Combined use of 18F FDG PET and 99mTc Sestamibi GSPECT in hearth transplant patients follow-up
    De Rimini, M. L.
    Catalano, M.
    Borrelli, G.
    Magliulo, B.
    Piccolo, S.
    Bifulco, M.
    Maiello, C.
    Barbato, F.
    Muto, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S386 - S386
  • [42] Oncologic information provided by immunoscintigraphy with 99mTc Fab′ fragments compared with [18F]FDG PET in colorectal cancer.
    Baehre, MH
    Markert, U
    Meller, B
    Lauer, I
    Haase, A
    Eckerle, S
    Richter, E
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 141P - 141P
  • [43] Radiation Exposure Assessment of Unclassified People Who Come into Contact with Patients Undergoing Nuclear Medicine 99mTc Investigations
    Nardella, G.
    Urbano, N.
    Cintoli, M. R.
    Pinto, L.
    Modoni, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S342 - S342
  • [44] [18F]PSMA-1007 PET is comparable to [99mTc]Tc-DMSA SPECT for renal cortical imaging
    Kristian Valind
    David Minarik
    Sabine Garpered
    Eva Persson
    Jonas Jögi
    Elin Trägårdh
    European Journal of Hybrid Imaging, 7
  • [45] [18F]PSMA-1007 PET is comparable to [99mTc]Tc-DMSA SPECT for renal cortical imaging
    Valind, Kristian
    Minarik, David
    Garpered, Sabine
    Persson, Eva
    Jogi, Jonas
    Tragardh, Elin
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2023, 7 (01):
  • [46] An ultra-high-energy collimator for small animal imaging in dual-isotope study of 18F and 99mTc
    Kubo, N
    Zhao, SJ
    Kinda, A
    Motomura, N
    Katoh, C
    Kuge, Y
    Tamaki, N
    PET AND MOLECULAR IMAGING: STATE OF THE ART AND FUTURE PERSPECTIVES, 2004, 1264 : 275 - 279
  • [47] External radiation exposure of nuclear medicine personnel using an automatic 18F dispenser
    Matheoudf, R.
    Lizio, D.
    Sacchetti, G.
    Brambilla, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S272 - S272
  • [48] Different PSMA Radiopharmaceuticals: A Comparative Study of [18F]F-PSMA-1007, [18F]F-JK-PSMA-7, and [99mTc]Tc-PSMA-I&S in the Skeletal System
    Miko, Zsofia Sara
    Varga, Laszlo
    Farkas, Istvan
    Toth, Gyula
    Apro, Kristof
    Revesz, Barnabas Mark
    Sipka, Gabor
    Tompa, Peter Gergo
    Bakos, Annamaria
    Czekus, Tamas
    Bukva, Matyas
    Pavics, Laszlo
    Varga, Linda
    Maraz, Aniko
    Besenyi, Zsuzsanna
    PHARMACEUTICALS, 2024, 17 (11)
  • [49] Finding the appropriate tool for the accurate prediction of microsphere biodistribution: SIR-Spheres radiolabelled with 18F, 111In and 99mTc
    Kersemans, Ken
    Courtyn, Jan
    Brans, Boudewijn
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [50] Shielding efficiency of novel tungsten rubber against radionuclides of 99mTc, 131I, 18F and 68Ga
    Kijima, Kenta
    Krisanachinda, Anchali
    Pasawang, Panya
    Hanaoka, Kohei
    Monzen, Hajime
    Nishimura, Yasumasa
    RADIATION PHYSICS AND CHEMISTRY, 2020, 172 (172)