Permeability of gloves used in nuclear medicine departments to [99mTc]-pertechnetate and [18F]-fluorodeoxyglucose: Radiation protection considerations

被引:1
|
作者
Ridone, S. [1 ]
Matheoud, R. [1 ]
Valzano, S. [1 ]
Di Martino, R. [2 ]
Vigna, L. [1 ]
Brambilla, M. [1 ]
机构
[1] Univ Hosp Maggiore Della Carita Novara, Dept Med Phys, I-28100 Novara, Italy
[2] Univ Oriental Piedmont, Sch Med, I-28100 Novara, Italy
来源
关键词
Gloves; Permeability [(99)mTc]-pertechnetate; F-18]-FDG; Radiation protection; SKIN CONTAMINATION; RADIONUCLIDE;
D O I
10.1016/j.ejmp.2013.01.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In order to evaluate the safety of the individual protection devices, the permeability of four different types of disposable gloves, commonly used in hospitals, was tested in relation to [Tc-99m]-pertechnetate and to [F-18]-fluorodeoxyglucose ([F-18]-FDG). From these radiopharmaceutical solutions, a drop was deposited on the external surface of the glove which was opened and stretched with the external surface placed upward. The smear test technique permitted to evaluate the activity onto the inner surface of the glove at different times. The smear tests were measured in a well sodium iodide detector calibrated in efficiency for Tc-99m and F-18. The permeability was tested on ten samples of each type of gloves and was expressed as the ratio of the activity onto the inner surface at each time interval to the activity deposited on the external surface of the glove. For each type of gloves and for each sampling time, mean value, standard deviation and percentage coefficient of variation of permeability were evaluated. One type of gloves showed a low resistance to permeation of both radiopharmaceuticals, while another one only to pertechnetate. The other gloves were good performers. The results of this study suggest to test permeability for gloves used for handling radiopharmaceuticals, before their adoption in the clinical routine. This practice will provide a more careful service of radiation protection for nuclear medicine department staff. (C) 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:545 / 548
页数:4
相关论文
共 50 条
  • [21] Prospective Evaluation of 99mTc MDP Scintigraphy, 18F NaF PET/CT, and 18F FDG PET/CT for Detection of Skeletal Metastases
    Andrei Iagaru
    Erik Mittra
    David W. Dick
    Sanjiv Sam Gambhir
    Molecular Imaging and Biology, 2012, 14 : 252 - 259
  • [22] Cardiac 99mTc sestamibi SPECT and 18F FDG PET as viability markers in takotsubo cardiomyopathy
    Thomas Emil Christensen
    Lia Evi Bang
    Lene Holmvang
    Adam Ali Ghotbi
    Martin Lyngby Lassen
    Flemming Andersen
    Nikolaj Ihlemann
    Hedvig Andersson
    Peer Grande
    Andreas Kjaer
    Philip Hasbak
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1407 - 1416
  • [23] Prospective Evaluation of 99mTc MDP Scintigraphy, 18F NaF PET/CT, and 18F FDG PET/CT for Detection of Skeletal Metastases
    Iagaru, Andrei
    Mittra, Erik
    Dick, David W.
    Gambhir, Sanjiv Sam
    MOLECULAR IMAGING AND BIOLOGY, 2012, 14 (02) : 252 - 259
  • [24] Radiation nephritis: 99mTc hydroxydiphosphonate bone scan, 99mTc dimercaptosuccinic acid renal scan, and 18F-FDG PET/CT findings
    Park, Hye Lim
    Yoo, Ie Ryung
    Kim, Yeon Sil
    Kang, Jin-Hyoung
    Lee, Ji Eun
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2018, 33 (04): : 837 - 838
  • [25] Radiation doses absorbed by technologists during different working situations with 99mTc in a nuclear medicine department
    Eklöf-Areskog, G
    Nilsson, MI
    Persson, L
    Göransson, A
    Hammarin, M
    Arlbrandt, A
    Franzén, M
    Starck, SÅ
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S489 - S489
  • [26] Interictal and ICTAL [99mTc]-HMPAO SPECT, [18F]FDG PET and MRI in temporal lobe epilepsy
    Asenbaum, S
    Diemling, M
    Hoffmann, M
    Becherer, A
    Baumgartner, C
    Olbrich, A
    Görzer, H
    Kletter, K
    Dudczak, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (01): : S92 - S92
  • [27] Performance of a dual, solid-state intraoperative probe system with 18F, 99mTc, and 111In
    Raylman, RR
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (02) : 352 - 360
  • [28] Preparation and evaluation of a single tetrazine-based synthon for labeling biomolecules with both 99mTc and 18F
    Vito, Alyssa R.
    Alarabi, Hosen
    Kent, Jeff
    Valliant, John
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2015, 58 : S18 - S18
  • [29] Can the function of the tubarial glands be evaluated using [99mTc]pertechnetate SPECT/CT, [18F]FDG PET/CT, and [11C]methionine PET/CT?
    Yohji Matsusaka
    Tomohiko Yamane
    Kenji Fukushima
    Akira Seto
    Ichiro Matsunari
    Ichiei Kuji
    EJNMMI Research, 11
  • [30] Can the function of the tubarial glands be evaluated using [99mTc]pertechnetate SPECT/CT, [18F]FDG PET/CT, and [11C]methionine PET/CT?
    Matsusaka, Yohji
    Yamane, Tomohiko
    Fukushima, Kenji
    Seto, Akira
    Matsunari, Ichiro
    Kuji, Ichiei
    EJNMMI RESEARCH, 2021, 11 (01)