Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT

被引:102
|
作者
Maret, D. [1 ,2 ]
Telmon, N. [1 ,3 ]
Peters, O. A. [4 ]
Lepage, B. [5 ]
Treil, J. [1 ]
Inglese, J. M. [6 ]
Peyre, A. [2 ]
Kahn, J. L. [7 ]
Sixou, M. [2 ,8 ]
机构
[1] Univ Toulouse 3, Lab Anthropol Mol & Imagerie Synt, CNRS, UMR 5288, F-31000 Toulouse, France
[2] Univ Toulouse 3, Fac Chirurg Dent, Ctr Hosp Univ, F-31000 Toulouse, France
[3] Hop Ramgueil, Serv Med Legale, Toulouse, France
[4] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
[5] Ctr Hosp Univ, Serv Epidemiol, Toulouse, France
[6] Carestream Hlth Inc, Dent Syst Grp, Marne La Vallee, France
[7] Inst Anat Normale Strasbourg, Strasbourg, France
[8] Univ Toulouse 3, MPDSB, Lab Univ LU 51, F-31000 Toulouse, France
关键词
cone-beam computed tomography; X-ray microtomography; three-dimensional imaging; MICRO-COMPUTED TOMOGRAPHY; AGE ESTIMATION; CANALS; MOLARS; IMAGES; FILES; CBCT;
D O I
10.1259/dmf/81804525
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. Methods: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D (R) CBCT (Carestream Health, Inc., Marne-la-Vallee, France), which has two voxel sizes: 200 mu m (CBCT 200 mu m group) and 300 mu m (CBCT 300 mu m group). These teeth had also been scanned with the KODAK 9000 3D (R) CBCT (Carestream Health, Inc.) (CBCT 76 mu m group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Bruttisellen, Switzerland) (micro-CT 41 mu m group) considered as references. After semi-automatic segmentation with AMIRA (R) software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. Results: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 mu m and 300 mu m groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 mu m group relative to the two reference groups (Passing-Bablok method). Conclusions: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed. Dentomaxillofacial Radiology (2012) 41, 649-655. doi: 10.1259/dmf/81804525
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [11] Automatic calibration method of voxel size for cone-beam 3D-CT scanning system
    杨民
    王晓龙
    刘义鹏
    孟凡勇
    李兴东
    刘文丽
    魏东波
    Chinese Physics C, 2014, (04) : 75 - 80
  • [12] Effect of Cone Beam Factor On Cone Beam CT Number Accuracy
    Yao, W.
    Hua, C.
    Farr, J.
    Brady, S.
    Merchant, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3455 - 3456
  • [13] Effects of Voxel Size On Visibility of Microcalcifications in Cone Beam Breast CT
    Shen, Y.
    Chen, L.
    Zhong, Y.
    Ge, S.
    Han, T.
    Yi, Y.
    You, Z.
    Liu, X.
    Lai, C.
    Wang, T.
    Shaw, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [14] Cervical vertebrae maturation index estimates on cone beam CT: 3D reconstructions vs sagittal sections
    Bonfim, Marco A. E.
    Costa, Andre L. F.
    Fuziy, Acacio
    Ximenez, Michel E. L.
    Cotrim-Ferreira, Flavio A.
    Ferreira-Santos, Rivea I.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (01)
  • [15] Cone beam optical CT scanner for 3D dosimetry
    Miller, J
    Adamovics, J
    Dietrich, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2138 - 2138
  • [16] Effect of voxel size on 3D micro-CT analysis of cortical bone porosity
    Cooper, David
    Turinsky, Andrei
    Sensen, Christoph
    Hallgrimsson, Benedikt
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 (03) : 211 - 219
  • [17] Effect of Voxel Size on 3D Micro-CT Analysis of Cortical Bone Porosity
    David Cooper
    Andrei Turinsky
    Christoph Sensen
    Benedikt Hallgrimsson
    Calcified Tissue International, 2007, 80 : 211 - 219
  • [18] Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT
    Kim, Mija
    Huh, Kyung-Hoe
    Yi, Won-Jin
    Heo, Min-Suk
    Lee, Sam-Sun
    Choi, Soon-Chul
    IMAGING SCIENCE IN DENTISTRY, 2012, 42 (01) : 25 - 33
  • [19] 3D CT pancreatography vs. cone beam CT pancreatography
    Ueno, J
    Kitagawa, M
    Makimoto, Y
    Matsuzaki, K
    Yoshida, S
    Nishitani, H
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 982 - 982
  • [20] kVp, mA, and voxel size effect on 3D voxel-based superimposition
    Eliliwi, Manhal
    Bazina, Mohamed
    Palomo, Juan Martin
    ANGLE ORTHODONTIST, 2020, 90 (02) : 269 - 277