Effect of Voxel Size on 3D Micro-CT Analysis of Cortical Bone Porosity

被引:0
|
作者
David Cooper
Andrei Turinsky
Christoph Sensen
Benedikt Hallgrimsson
机构
[1] University of British Columbia,Department of Orthopaedics, Division of Orthopaedic Engineering Research
[2] VGH - Research Pavilion,Department of Biochemistry and Molecular Biology
[3] University of Calgary,Department of Cell Biology and Anatomy
[4] University of Calgary,undefined
来源
关键词
Micro-CT; Cortical porosity; 3D; Cortical bone; Voxel size; Bone density technology; Bone histology & Histomorphometry; Bone architecture/structure;
D O I
暂无
中图分类号
学科分类号
摘要
This study examines the impact of voxel size on 3D micro-CT analysis of human cortical bone porosity. The study is based on computed microtomography scans of 10 human anterior femoral midshaft specimens acquired at 5, 10, and 15 μm voxel sizes. Artificial voxel sizes (10, 20, and 40 μm) were generated from the smallest scan voxel size (5 μm) in order to compare actual scanning with artificial degradation, a method employed in other similar studies. Canal volume fraction (CaV/TV), canal surface to volume ratio (CaS/CaV), mean canal diameter (CaDm), mean canal separation (CaSp), canal number (CaN), degree of anisotropy (DA), and canal connectivity density (CaConnD) were calculated from matching volumes of interest for all datasets. Qualitatively, the clarity of the actual scan datasets deteriorated rapidly as voxel size increased. In contrast, within the artificially generated datasets, the clarity of cortical pores was better maintained until the largest voxel size (40 μm). Mean absolute percent error values, correlation coefficients, and paired t-tests revealed a pattern of increasing, and generally significant, differences between the smallest and progressively larger voxel sizes (both scanned and artificial). Relative to the actual scans, however, the artificial datasets were less sensitive to changing voxel size. These findings indicated that subtle changes in voxel size, within the range examined, have a considerable effect on human cortical porosity structural parameters. Additionally, the use of artificially increased voxel sizes should be viewed with caution as they may not reflect what can actually be obtained by scanning.
引用
收藏
页码:211 / 219
页数:8
相关论文
共 50 条
  • [1] Effect of voxel size on 3D micro-CT analysis of cortical bone porosity
    Cooper, David
    Turinsky, Andrei
    Sensen, Christoph
    Hallgrimsson, Benedikt
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2007, 80 (03) : 211 - 219
  • [2] The impact of scan resolution on 3D quantitative analysis of cortical bone porosity by micro-CT
    Turinsky, AL
    Cooper, DML
    Hallgrimsson, B
    Sensen, CW
    [J]. FASEB JOURNAL, 2004, 18 (05): : A785 - A785
  • [3] The application of 3D μCT to the analysis of cortical bone porosity
    Cooper, D
    Hallgrimsson, B
    [J]. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2002, : 56 - 57
  • [4] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [5] 3D micro-CT analysis of cancellous bone architecture
    Rossi, M
    Casali, F
    Romani, D
    Carabini, ML
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 349 - 358
  • [6] 3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia
    Britz, H. M.
    Jokihaara, J.
    Leppanen, O. V.
    Jarvinen, T.
    Cooper, D. M. L.
    [J]. JOURNAL OF MICROSCOPY, 2010, 240 (01) : 32 - 37
  • [7] 3D visualization of human cortical bone remodeling spaces using micro-CT data
    Wei, Xuan
    Cooper, David M. L.
    [J]. AMERICAN JOURNAL OF BIOLOGICAL ANTHROPOLOGY, 2023, 180 : 192 - 192
  • [8] Micro-CT characterization on porosity structure of 3D Cf/SiCm composite
    Feng, Yanjian
    Feng, Zude
    Li, Siwei
    Zhang, Weihua
    Luan, Xingan
    Liu, Yongsheng
    Cheng, Laifei
    Zhang, Litong
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2011, 42 (11) : 1645 - 1650
  • [9] Effect of Voxel Size of Micro-CT on the Assessment of Root Canal Preparation
    Pinto, Jader Camilo
    Lucas-Oliveira, Everton
    Bonagamba, Tito Jose
    Guerreiro-Tanomaru, Juliane Maria
    Tanomaru-Filho, Mario
    [J]. ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2023, 25 (02) : 93 - 102
  • [10] High-resolution micro-CT with 3D image analysis for porosity characterization of historic bricks
    Chandra L. Reedy
    Cara L. Reedy
    [J]. Heritage Science, 10