3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia

被引:40
|
作者
Britz, H. M.
Jokihaara, J. [2 ]
Leppanen, O. V. [3 ]
Jarvinen, T. [3 ]
Cooper, D. M. L. [1 ]
机构
[1] Univ Saskatchewan, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Tampere, FIN-33101 Tampere, Finland
关键词
Cortical bone; cortical porosity; histology; micro-CT; rat; synchrotron; MICROCOMPUTED TOMOGRAPHY; MORPHOMETRIC-ANALYSIS; COMPUTED TOMOGRAPHY; CANCELLOUS BONE; TRABECULAR BONE; MICROSTRUCTURE; SECTIONS; SCAFFOLDS; THICKNESS; SIZE;
D O I
10.1111/j.1365-2818.2010.03381.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
P>Although micro-computed tomography (micro-CT) has become the gold standard for assessing the 3D structure of trabecular bone, its extension to cortical bone microstructure has been relatively limited. Desktop micro-CT has been employed to assess cortical bone porosity of humans, whereas that of smaller animals, such as mice and rats, has thus far only been imaged using synchrotron-based micro-CT. The goal of this study was to determine if it is possible to visualize and quantify rat cortical porosity using desktop micro-CT. Tibiae (n = 10) from 30-week-old female Sprague-Dawley rats were imaged with micro-CT (3 mu m nominal resolution) and sequential ground sections were then prepared. Bland-Altman plots were constructed to compare per cent porosity and mean canal diameter from micro-CT (3D) versus histology (2D). The mean difference or bias (histology - micro-CT; +/- 95% confidence interval) for per cent porosity was found to be -0.15% (+/- 2.57%), which was not significantly different from zero (P = 0.720). Canal diameter had a bias (+/- 95% confidence interval) of -5.73 mu m (+/- 4.02 mu m) which was found to be significantly different from zero (P < 0.001). The results indicated that cortical porosity in rat bone can indeed be visualized by desktop micro-CT. Quantitative assessment of per cent porosity provided unbiased results, whereas direct analysis of mean canal diameter was overestimated by micro-CT. Thus, although higher resolution, such as that available from synchrotron micro-CT, may ultimately be required for precise geometric measurements, desktop micro-CT - which is far more accessible - is capable of yielding comparable measures of porosity and holds great promise for assessment of the 3D arrangement of cortical porosity in the rat.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 50 条
  • [1] 3D visualization of human cortical bone remodeling spaces using micro-CT data
    Wei, Xuan
    Cooper, David M. L.
    [J]. AMERICAN JOURNAL OF BIOLOGICAL ANTHROPOLOGY, 2023, 180 : 192 - 192
  • [2] Effect of voxel size on 3D micro-CT analysis of cortical bone porosity
    Cooper, David
    Turinsky, Andrei
    Sensen, Christoph
    Hallgrimsson, Benedikt
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2007, 80 (03) : 211 - 219
  • [3] Effect of Voxel Size on 3D Micro-CT Analysis of Cortical Bone Porosity
    David Cooper
    Andrei Turinsky
    Christoph Sensen
    Benedikt Hallgrimsson
    [J]. Calcified Tissue International, 2007, 80 : 211 - 219
  • [4] The impact of scan resolution on 3D quantitative analysis of cortical bone porosity by micro-CT
    Turinsky, AL
    Cooper, DML
    Hallgrimsson, B
    Sensen, CW
    [J]. FASEB JOURNAL, 2004, 18 (05): : A785 - A785
  • [5] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [6] Age-related changes in the 3D hierarchical structure of rat tibia cortical bone characterized by high-resolution micro-CT
    Jast, John
    Jasiuk, Iwona
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2013, 114 (07) : 923 - 933
  • [7] 3D visualization of the microstructure of Quedius beesoni Cameron using micro-CT
    Zhang, Kai
    Li, De-e
    Zhu, Peiping
    Yuan, Qingxi
    Huang, Wanxia
    Liu, Xiaosong
    Hong, Youli
    Gao, Gun
    Ge, Xin
    Zhou, Hongzhang
    Wu, Ziyu
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (06) : 2143 - 2148
  • [8] 3D visualization of the microstructure of Quedius beesoni Cameron using micro-CT
    Kai Zhang
    De-e Li
    Peiping Zhu
    Qingxi Yuan
    Wanxia Huang
    Xiaosong Liu
    Youli Hong
    Gun Gao
    Xin Ge
    Hongzhang Zhou
    Ziyu Wu
    [J]. Analytical and Bioanalytical Chemistry, 2010, 397 : 2143 - 2148
  • [9] 3D Visualization and Volume-Based Quantification of Rice Chalkiness In Vivo by Using High Resolution Micro-CT
    Yi Su
    Lang-Tao Xiao
    [J]. Rice, 2020, 13
  • [10] 3D Visualization and Volume-Based Quantification of Rice Chalkiness In Vivo by Using High Resolution Micro-CT
    Su, Yi
    Xiao, Lang-Tao
    [J]. RICE, 2020, 13 (01)