3D visualization and quantification of rat cortical bone porosity using a desktop micro-CT system: a case study in the tibia

被引:41
|
作者
Britz, H. M.
Jokihaara, J. [2 ]
Leppanen, O. V. [3 ]
Jarvinen, T. [3 ]
Cooper, D. M. L. [1 ]
机构
[1] Univ Saskatchewan, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Tampere, FIN-33101 Tampere, Finland
关键词
Cortical bone; cortical porosity; histology; micro-CT; rat; synchrotron; MICROCOMPUTED TOMOGRAPHY; MORPHOMETRIC-ANALYSIS; COMPUTED TOMOGRAPHY; CANCELLOUS BONE; TRABECULAR BONE; MICROSTRUCTURE; SECTIONS; SCAFFOLDS; THICKNESS; SIZE;
D O I
10.1111/j.1365-2818.2010.03381.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
P>Although micro-computed tomography (micro-CT) has become the gold standard for assessing the 3D structure of trabecular bone, its extension to cortical bone microstructure has been relatively limited. Desktop micro-CT has been employed to assess cortical bone porosity of humans, whereas that of smaller animals, such as mice and rats, has thus far only been imaged using synchrotron-based micro-CT. The goal of this study was to determine if it is possible to visualize and quantify rat cortical porosity using desktop micro-CT. Tibiae (n = 10) from 30-week-old female Sprague-Dawley rats were imaged with micro-CT (3 mu m nominal resolution) and sequential ground sections were then prepared. Bland-Altman plots were constructed to compare per cent porosity and mean canal diameter from micro-CT (3D) versus histology (2D). The mean difference or bias (histology - micro-CT; +/- 95% confidence interval) for per cent porosity was found to be -0.15% (+/- 2.57%), which was not significantly different from zero (P = 0.720). Canal diameter had a bias (+/- 95% confidence interval) of -5.73 mu m (+/- 4.02 mu m) which was found to be significantly different from zero (P < 0.001). The results indicated that cortical porosity in rat bone can indeed be visualized by desktop micro-CT. Quantitative assessment of per cent porosity provided unbiased results, whereas direct analysis of mean canal diameter was overestimated by micro-CT. Thus, although higher resolution, such as that available from synchrotron micro-CT, may ultimately be required for precise geometric measurements, desktop micro-CT - which is far more accessible - is capable of yielding comparable measures of porosity and holds great promise for assessment of the 3D arrangement of cortical porosity in the rat.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 50 条
  • [21] Laboratory 3D Micro-XRF/Micro-CT Imaging System
    Bruyndonckx, P.
    Sasov, A.
    Liu, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 61 - 64
  • [22] Segmentation of cortical bone, trabecular bone, and medullary pores from micro-CT images using 2D and 3D deep learning models
    Lee, Andrew H.
    Moore, Julian M.
    Covarrubias, Brandon Vera
    Lynch, Leigha M.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2025,
  • [23] Assessment of Vascular Calcification Using Micro-CT Quantification in a Vitamin D Rat Model
    Bassissi, Firas
    Sabador, David
    Ferrer, Marc Blasco
    Perez, Guillermo Garaulet
    del Mar Perez, Maria
    Ferrer, Miquel D.
    Mulero, Francisca
    Salcedo, Carolina
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 203 - 203
  • [24] 3D Morphological Analysis of Age and Sex-Related Changes in Human Cortical Bone Remodeling Spaces Using Micro-CT
    Wei, Xuan
    Loundagin, Lindsay
    Cooper, David Michael Lane
    JOURNAL OF BONE AND MINERAL RESEARCH, 2024, 39 : 126 - 126
  • [25] 3D osteocyte lacunar morphometric properties and distributions in human femoral cortical bone using synchrotron radiation micro-CT images
    Dong, Pei
    Haupert, Sylvain
    Hesse, Bernhard
    Langer, Max
    Gouttenoire, Pierre-Jean
    Bousson, Valerie
    Peyrin, Francoise
    BONE, 2014, 60 : 172 - 185
  • [26] Bone microarchitectural assessment in male idiopathic osteoporosis by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A. C.
    Perez Edo, L.
    Marinoso, M.
    Blanche, J.
    Carbonell, J.
    Wehrli, F. W.
    BONE, 2007, 40 (06) : S259 - S260
  • [27] Bone microarchitectural assessment in male idiopathic osteoporosis by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A.
    Perez-Edo, L.
    Blanch, J.
    Marinoso, M.
    Ciria, M.
    Rotes, D.
    Carbonell, J.
    Wehrli, F.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S161 - S161
  • [28] Bone microarchitectural changes in rheumatoid arthritis assessed by 3D micro-CT
    Garcia-Miguel, J.
    Wright, A.
    Perez-Edo, L.
    Blanch, J.
    Marinoso, M.
    Ciria, M.
    Rotes, D.
    Carbonell, J.
    Wehrli, F.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S160 - S161
  • [29] 3D characterization of porosity and authigenic cementation in Triassic conglomerates/arenites in the Edvard Grieg field using 3D micro-CT imaging
    Markussen, Orjan
    Dypvik, Henning
    Hammer, Erik
    Long, Haili
    Hammer, Oyvind
    MARINE AND PETROLEUM GEOLOGY, 2019, 99 : 265 - 281
  • [30] Validation of a micro-CT system for the 3-D measurement of bone.
    Chmielewski, PA
    Dufresne, TE
    Combs, KH
    Borah, B
    Lundy, MW
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 : S461 - S461