Effect of voxel size on the accuracy of 3D reconstructions with cone beam CT

被引:102
|
作者
Maret, D. [1 ,2 ]
Telmon, N. [1 ,3 ]
Peters, O. A. [4 ]
Lepage, B. [5 ]
Treil, J. [1 ]
Inglese, J. M. [6 ]
Peyre, A. [2 ]
Kahn, J. L. [7 ]
Sixou, M. [2 ,8 ]
机构
[1] Univ Toulouse 3, Lab Anthropol Mol & Imagerie Synt, CNRS, UMR 5288, F-31000 Toulouse, France
[2] Univ Toulouse 3, Fac Chirurg Dent, Ctr Hosp Univ, F-31000 Toulouse, France
[3] Hop Ramgueil, Serv Med Legale, Toulouse, France
[4] Univ Pacific, Arthur A Dugoni Sch Dent, Dept Endodont, San Francisco, CA USA
[5] Ctr Hosp Univ, Serv Epidemiol, Toulouse, France
[6] Carestream Hlth Inc, Dent Syst Grp, Marne La Vallee, France
[7] Inst Anat Normale Strasbourg, Strasbourg, France
[8] Univ Toulouse 3, MPDSB, Lab Univ LU 51, F-31000 Toulouse, France
关键词
cone-beam computed tomography; X-ray microtomography; three-dimensional imaging; MICRO-COMPUTED TOMOGRAPHY; AGE ESTIMATION; CANALS; MOLARS; IMAGES; FILES; CBCT;
D O I
10.1259/dmf/81804525
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The various types of cone beam CT (CBCT) differ in several technical characteristics, notably their spatial resolution, which is defined by the acquisition voxel size. However, data are still lacking on the effects of voxel size on the metric accuracy of three-dimensional (3D) reconstructions. This study was designed to assess the effect of isotropic voxel size on the 3D reconstruction accuracy and reproducibility of CBCT data. Methods: The study sample comprised 70 teeth (from the Institut d'Anatomie Normale, Strasbourg, France). The teeth were scanned with a KODAK 9500 3D (R) CBCT (Carestream Health, Inc., Marne-la-Vallee, France), which has two voxel sizes: 200 mu m (CBCT 200 mu m group) and 300 mu m (CBCT 300 mu m group). These teeth had also been scanned with the KODAK 9000 3D (R) CBCT (Carestream Health, Inc.) (CBCT 76 mu m group) and the SCANCO Medical micro-CT XtremeCT (SCANCO Medical, Bruttisellen, Switzerland) (micro-CT 41 mu m group) considered as references. After semi-automatic segmentation with AMIRA (R) software (Visualization Sciences Group, Burlington, MA), tooth volumetric measurements were obtained. Results: The Bland-Altman method showed no difference in tooth volumes despite a slight underestimation for the CBCT 200 mu m and 300 mu m groups compared with the two reference groups. The underestimation was statistically significant for the volumetric measurements of the CBCT 300 mu m group relative to the two reference groups (Passing-Bablok method). Conclusions: CBCT is not only a tool that helps in diagnosis and detection but it has the complementary advantage of being a measuring instrument, the accuracy of which appears connected to the size of the voxels. Future applications of such measurements with CBCT are discussed. Dentomaxillofacial Radiology (2012) 41, 649-655. doi: 10.1259/dmf/81804525
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [41] Cone-Beam Angle Dependency of 3D Models Computed from Cone-Beam CT Images
    Cho, Myung Hye
    Hegazy, Mohamed A. A.
    Cho, Min Hyoung
    Lee, Soo Yeol
    SENSORS, 2022, 22 (03)
  • [42] Improved accuracy assessment for 3D genome reconstructions
    Segal, Mark R.
    Bengtsson, Henrik L.
    BMC BIOINFORMATICS, 2018, 19
  • [43] Effects of voxel size and resolution on the accuracy of endodontic length measurement using cone beam computed tomography
    Aktan, Ali Murat
    Yildirim, Cihan
    Karataslioglu, Emrah
    Ciftci, Mehmet Ertugrul
    Aksoy, Fatih
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2016, 208 : 96 - 102
  • [44] Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT
    Dusseldorp, J. K.
    Stamatakis, H. C.
    Ren, Y.
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (03) : 921 - 930
  • [45] Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT
    J. K. Dusseldorp
    H. C. Stamatakis
    Y. Ren
    Clinical Oral Investigations, 2017, 21 : 921 - 930
  • [46] Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling
    Tward, Daniel J.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2009, 36 (08) : 3830 - 3843
  • [48] Comparison of the Accuracy of 3-dimensional Cone-beam Computed Tomography and Micro-Computed Tomography Reconstructions by Using Different Voxel Sizes
    Maret, Delphine
    Peters, Ove A.
    Galibourg, Antoine
    Dumoncel, Jean
    Esclassan, Remi
    Kahn, Jean-Luc
    Sixou, Michel
    Telmon, Norbert
    JOURNAL OF ENDODONTICS, 2014, 40 (09) : 1321 - 1326
  • [49] Photoacoustic tomography versus cone-beam computed tomography versus micro-computed tomography: Accuracy of 3D reconstructions of human teeth
    Schneider, Sonja Jasmin Maria
    Hoehne, Christian
    Schneider, Martin
    Schmitter, Marc
    PLOS ONE, 2022, 17 (12):
  • [50] CLINICAL USE OF THE CONE BEAM CT FOR 3D IMAGE GUIDED GYN BRACHYTHERAPY
    Reniers, B.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S366 - S367