Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model

被引:101
|
作者
Renner, Jochen [1 ]
Gruenewald, Matthias [1 ]
Quaden, Rene [2 ]
Hanss, Robert [1 ]
Meybohm, Patrick [1 ]
Steinfath, Markus [1 ]
Scholz, Jens [1 ]
Bein, Berthold [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesia & Intens Care Med, Campus Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Cardiothorac & Vasc Surg, Campus Kiel, Germany
关键词
pneumoperitoneum; intra-abdominal pressure; intraabdominal hypertension; fluid responsiveness; preload; monitoring; pulse pressure variation; stroke volume variation; global end-diastolic volume; ABDOMINAL COMPARTMENT SYNDROME; INTRATHORACIC BLOOD-VOLUME; END-DIASTOLIC VOLUME; CRITICALLY-ILL PATIENTS; CARDIAC-OUTPUT; INTERNATIONAL-CONFERENCE; RESPIRATORY CHANGES; PERFUSION-PRESSURE; SUPERIOR PARAMETER; LOADING CONDITIONS;
D O I
10.1097/CCM.0b013e3181959864
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Dynamic variables of fluid responsiveness such as pulse pressure variation (PPV) and stroke volume variation (SVV) have been shown to reliably predict the response to fluid administration in different patient populations. The influence of increased intra-abdominal pressure (IAP) on the predictive ability of these variables is currently under debate. Therefore, the present study was designed to evaluate whether PPV and SVV are suitable for predicting fluid responsiveness during elevated IAP. Design: Prospective controlled experimental study. Setting. Animal research laboratory. Subjects. 14 anesthetized and mechanically ventilated pigs. Interventions: Pigs were studied at different experimental stages: normovolemia at baseline conditions, after induction of pneumoperitoneum (PP) by increasing IAP up to 25 mm Hg, followed by releasing PIP and performing a fluid load with 1000 cc hydroxyl-ethyl starch 6%, and finally after inducing PP again. Cardiac output, stroke volume, central venous pressure, and pulmonary artery occlusion pressure were obtained by pulmonary artery thermodilution. Additionally, global end-diastolic volume (GEDV) was measured by transpulmonary thermodilution. PPV and SVV were monitored continuously by pulse contour analysis. Measurements and Main Results: PP induced significant changes in peak airway pressure, esophageal pressure, chest wall compliance, SVV, PPV, central venous pressure, and pulmonary artery occlusion pressure independent of loading conditions. As assessed by receiver operating characteristic curve analysis, PPV, SVV, and GEDV accurately predicted fluid responsiveness before IAP was increased (area under the curve: 0.90, 0.91 and 0.91). A PPV value of >= 11.5%, a SVV value of >= 9.5%, and a GEDV value of <= 963 mL accurately predicted an increase in stroke volume >= 15%. After increasing IAP, the ability of SVV to predict fluid responsiveness was abolished, whereas it was preserved with both PPV and GEDV, although the threshold value for PPV dramatically increased up to >= 20.5%. Conclusions. In this animal model PPV and GEDV proved to be sensitive and specific predictors of fluid responsiveness even during increased IAP. (Crit Care Med 2009; 37:650-658)
引用
收藏
页码:650 / 658
页数:9
相关论文
共 50 条
  • [21] Influence of volume increase on intra-abdominal pressure
    Schachtrupp, A.
    ANAESTHESIST, 2009, 58 (05): : 532 - 536
  • [22] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Messina, Antonio
    Caporale, Mariagiovanna
    Calabro, Lorenzo
    Lionetti, Giulia
    Bono, Daniele
    Matronola, Guia Margherita
    Brunati, Andrea
    Frassanito, Luciano
    Morenghi, Emanuela
    Antonelli, Massimo
    Chew, Michelle S.
    Cecconi, Maurizio
    CRITICAL CARE, 2023, 27 (01)
  • [23] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Antonio Messina
    Mariagiovanna Caporale
    Lorenzo Calabrò
    Giulia Lionetti
    Daniele Bono
    Guia Margherita Matronola
    Andrea Brunati
    Luciano Frassanito
    Emanuela Morenghi
    Massimo Antonelli
    Michelle S. Chew
    Maurizio Cecconi
    Critical Care, 27
  • [24] The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    Wyffels, P. A. H.
    Sergeant, P.
    Wouters, P. F.
    ANAESTHESIA, 2010, 65 (07) : 704 - 709
  • [25] Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients
    Hong, Jin-Quan
    He, He-Fan
    Chen, Zhi-Yuan
    Du, Zhen-Shuang
    Liu, Wei-Feng
    Weng, Pei-Qing
    Huang, Hao-Bo
    SAUDI MEDICAL JOURNAL, 2014, 35 (03) : 261 - 268
  • [26] Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/Vigileo and automated pulse pressure variation
    Khwannimit, Bodin
    Bhurayanontachai, Rungsun
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (02) : 64 - 69
  • [27] Stroke volume variation compared with pulse pressure variation and cardiac index changes for prediction of fluid responsiveness in mechanically ventilated patients
    Soliman, Randa Aly
    Samir, Shereif
    el Naggar, Ayman
    El Dehely, Khalaf
    EGYPTIAN JOURNAL OF CRITICAL CARE MEDICINE, 2015, 3 (01): : 9 - 16
  • [28] Pressure controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients
    Ye, Weiguang
    Wang, Bin
    Wei, Limin
    Wang, Tianlong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10963 - 10970
  • [29] The impact of intra-abdominal pressure on the stroke volume variation and plethysmographic variability index in patients undergoing laparoscopic cholecystectomy
    Liu, Fangfang
    Zhu, Sihai
    Ji, Qing
    Li, Weiyan
    Liu, Jian
    BIOSCIENCE TRENDS, 2015, 9 (02) : 129 - 133
  • [30] Reading the Wave of Fluid Responsiveness With Pulse Pressure Variation
    Allan, Glenn
    CRITICAL CARE NURSE, 2012, 32 (02) : E58 - E59