Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression

被引:8
|
作者
Messina, Antonio [1 ,2 ]
Caporale, Mariagiovanna [3 ]
Calabro, Lorenzo [1 ,2 ]
Lionetti, Giulia [1 ,2 ]
Bono, Daniele [1 ,2 ]
Matronola, Guia Margherita [2 ]
Brunati, Andrea [2 ]
Frassanito, Luciano [3 ]
Morenghi, Emanuela [1 ,2 ]
Antonelli, Massimo [3 ]
Chew, Michelle S. [4 ]
Cecconi, Maurizio [1 ,2 ]
机构
[1] IRCCS Humanitas Res Hosp, Dept Anaesthesia & Intens Care Med, Via Manzoni 56, I-20089 Rozzano Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20072 Milan, Italy
[3] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli IRCCS, Dept Anesthesia & Intens Care, Rome, Italy
[4] Linkoping Univ, Dept Anaesthes & Intens Care, Biomed & Clin Sci, Linkoping, Sweden
关键词
Pulse pressure variation; Stroke volume variation; Fluid responsiveness; Fluid therapy; Hemodynamic monitoring; MECHANICALLY VENTILATED PATIENTS; LUNG RECRUITMENT MANEUVER; EXPIRATORY OCCLUSION TEST; PLETH VARIABILITY INDEX; CRITICALLY-ILL PATIENTS; CORRECTED FLOW TIME; WAVE-FORM AMPLITUDE; RESPIRATORY VARIATIONS; ESOPHAGEAL DOPPLER; TIDAL-VOLUME;
D O I
10.1186/s13054-023-04706-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BackgroundPulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia.MethodsSystematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables.ResultsWe selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position.ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
    Antonio Messina
    Mariagiovanna Caporale
    Lorenzo Calabrò
    Giulia Lionetti
    Daniele Bono
    Guia Margherita Matronola
    Andrea Brunati
    Luciano Frassanito
    Emanuela Morenghi
    Massimo Antonelli
    Michelle S. Chew
    Maurizio Cecconi
    Critical Care, 27
  • [2] Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review
    Jiaxin Chen
    Shuhua Zhao
    Qianqian Zhu
    Journal of Clinical Monitoring and Computing, 2023, 37 : 379 - 387
  • [3] Reliability of stroke volume or pulse pressure variation as dynamic predictors of fluid responsiveness in laparoscopic surgery: a systematic review
    Chen, Jiaxin
    Zhao, Shuhua
    Zhu, Qianqian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (02) : 379 - 387
  • [4] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [5] Stroke Volume Variation and Pulse Pressure Variation Are Not Useful for Predicting Fluid Responsiveness in Thoracic Surgery
    Jeong, Dae Myoung
    Ahn, Hyun Joo
    Park, Hyo Won
    Yang, Mikyung
    Kim, Jie Ae
    Park, Joohyun
    ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1158 - 1165
  • [6] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Marko Zlicar
    Vesna Novak-Jankovic
    Rok Blagus
    Maurizio Cecconi
    Journal of Clinical Monitoring and Computing, 2018, 32 : 825 - 832
  • [7] Accuracy of stroke volume variation and pulse pressure variation to predict fluid responsiveness in patients with thoracic kyphosis
    Chen, Yu
    Guo, Xiaomei
    Fu, Jiannan
    Dong, Tong
    Liu, Xiaomei
    Lv, Hao
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (07) : 7571 - 7578
  • [8] PULSE PRESSURE AND STROKE VOLUME VARIATION ARE GOOD PREDICTORS OF FLUID RESPONSIVENESS IN SEVERE SEPSIS PATIENTS
    Drvar, Z.
    Baronica, R.
    Tomasevic, B.
    Pavlek, M.
    Miric, M.
    Peric, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S202 - S202
  • [9] Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
    Kim, So Yeon
    Song, Young
    Shim, Jae Kwang
    Kwak, Young Lan
    JOURNAL OF CRITICAL CARE, 2013, 28 (03) : 318.e1 - 318.e7
  • [10] Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure Variation and Stroke Volume Variation for Assessing Fluid Responsiveness
    Joshi, Malini
    Dhakane, Praveen
    Bhosale, Shilpushp J.
    Phulambrikar, Rutuja
    Kulkarni, Atul P.
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2022, 26 (02) : 179 - 184