Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression

被引:8
|
作者
Messina, Antonio [1 ,2 ]
Caporale, Mariagiovanna [3 ]
Calabro, Lorenzo [1 ,2 ]
Lionetti, Giulia [1 ,2 ]
Bono, Daniele [1 ,2 ]
Matronola, Guia Margherita [2 ]
Brunati, Andrea [2 ]
Frassanito, Luciano [3 ]
Morenghi, Emanuela [1 ,2 ]
Antonelli, Massimo [3 ]
Chew, Michelle S. [4 ]
Cecconi, Maurizio [1 ,2 ]
机构
[1] IRCCS Humanitas Res Hosp, Dept Anaesthesia & Intens Care Med, Via Manzoni 56, I-20089 Rozzano Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20072 Milan, Italy
[3] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli IRCCS, Dept Anesthesia & Intens Care, Rome, Italy
[4] Linkoping Univ, Dept Anaesthes & Intens Care, Biomed & Clin Sci, Linkoping, Sweden
关键词
Pulse pressure variation; Stroke volume variation; Fluid responsiveness; Fluid therapy; Hemodynamic monitoring; MECHANICALLY VENTILATED PATIENTS; LUNG RECRUITMENT MANEUVER; EXPIRATORY OCCLUSION TEST; PLETH VARIABILITY INDEX; CRITICALLY-ILL PATIENTS; CORRECTED FLOW TIME; WAVE-FORM AMPLITUDE; RESPIRATORY VARIATIONS; ESOPHAGEAL DOPPLER; TIDAL-VOLUME;
D O I
10.1186/s13054-023-04706-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BackgroundPulse pressure and stroke volume variation (PPV and SVV) have been widely used in surgical patients as predictors of fluid challenge (FC) response. Several factors may affect the reliability of these indices in predicting fluid responsiveness, such as the position of the patient, the use of laparoscopy and the opening of the abdomen or the chest, combined FC characteristics, the tidal volume (Vt) and the type of anesthesia.MethodsSystematic review and metanalysis of PPV and SVV use in surgical adult patients. The QUADAS-2 scale was used to assess the risk of bias of included studies. We adopted a metanalysis pooling of aggregate data from 5 subgroups of studies with random effects models using the common-effect inverse variance model. The area under the curve (AUC) of pooled receiving operating characteristics (ROC) curves was reported. A metaregression was performed using FC type, volume, and rate as independent variables.ResultsWe selected 59 studies enrolling 2,947 patients, with a median of fluid responders of 55% (46-63). The pooled AUC for the PPV was 0.77 (0.73-0.80), with a mean threshold of 10.8 (10.6-11.0). The pooled AUC for the SVV was 0.76 (0.72-0.80), with a mean threshold of 12.1 (11.6-12.7); 19 studies (32.2%) reported the grey zone of PPV or SVV, with a median of 56% (40-62) and 57% (46-83) of patients included, respectively. In the different subgroups, the AUC and the best thresholds ranged from 0.69 and 0.81 and from 6.9 to 11.5% for the PPV, and from 0.73 to 0.79 and 9.9 to 10.8% for the SVV. A high Vt and the choice of colloids positively impacted on PPV performance, especially among patients with closed chest and abdomen, or in prone position.ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120ConclusionThe overall performance of PPV and SVV in operating room in predicting fluid responsiveness is moderate, ranging close to an AUC of 0.80 only some subgroups of surgical patients. The grey zone of these dynamic indices is wide and should be carefully considered during the assessment of fluid responsiveness. A high Vt and the choice of colloids for the FC are factors potentially influencing PPV reliability.Trial Registration: PROSPERO (CRD42022379120), December 2022. https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=379120
引用
收藏
页数:12
相关论文
共 50 条
  • [41] How Accurate Is Pulse Pressure Variation as a Predictor of Fluid Responsiveness?
    Verniquet, Andrew
    Kakel, Rafid
    ANESTHESIOLOGY, 2012, 116 (03) : 740 - 740
  • [42] Tidal volume challenge to predict fluid responsiveness in the operating room An observational study
    Messina, Antonio
    Montagnini, Claudia
    Cammarota, Gianmaria
    De Rosa, Silvia
    Giuliani, Fabiana
    Muratore, Lara
    Della Corte, Francesco
    Navalesi, Paolo
    Cecconi, Maurizio
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2019, 36 (08) : 583 - 591
  • [43] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [44] Is the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
    C Costa
    S Vieira
    G Friedman
    L Fialkow
    Critical Care, 13 (Suppl 1):
  • [45] Changes in Stroke Volume Induced by Lung Recruitment Maneuver Predict Fluid Responsiveness in Mechanically Ventilated Patients in the Operating Room
    Biais, Matthieu
    Lanchon, Romain
    Sesay, Musa
    Le Gall, Lisa
    Pereira, Bruno
    Futier, Emmanuel
    Nouette-Gaulain, Karine
    ANESTHESIOLOGY, 2017, 126 (02) : 260 - 267
  • [46] Pulse pressure variation, stroke volume variation and dynamic arterial elastance
    Raphael Giraud
    Nils Siegenthaler
    Karim Bendjelid
    Critical Care, 15
  • [47] Pulse pressure variation, stroke volume variation and dynamic arterial elastance
    Giraud, Raphael
    Siegenthaler, Nils
    Bendjelid, Karim
    CRITICAL CARE, 2011, 15 (02):
  • [48] Influences of different vasopressors on stroke volume variation and pulse pressure variation
    Kong, Ran
    Liu, Yi
    Mi, Weidong
    Fu, Qiang
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (01) : 81 - 86
  • [49] Influences of different vasopressors on stroke volume variation and pulse pressure variation
    Ran Kong
    Yi Liu
    Weidong Mi
    Qiang Fu
    Journal of Clinical Monitoring and Computing, 2016, 30 : 81 - 86
  • [50] PLETH VARIABILITY INDEX, PULSE PRESSURE AND STROKE VOLUME VARIATION DO NOT PREDICT FLUID RESPONSIVENESS IN VENTILATED PATIENTS WITH SEPTIC SHOCK TREATED WITH VASOPRESSORS
    Jagannathan, V. K.
    Sharma, S.
    Finn, P.
    Ryan, J.
    Mullenheim, J. W.
    INTENSIVE CARE MEDICINE, 2011, 37 : S89 - S89