Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model

被引:101
|
作者
Renner, Jochen [1 ]
Gruenewald, Matthias [1 ]
Quaden, Rene [2 ]
Hanss, Robert [1 ]
Meybohm, Patrick [1 ]
Steinfath, Markus [1 ]
Scholz, Jens [1 ]
Bein, Berthold [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesia & Intens Care Med, Campus Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Cardiothorac & Vasc Surg, Campus Kiel, Germany
关键词
pneumoperitoneum; intra-abdominal pressure; intraabdominal hypertension; fluid responsiveness; preload; monitoring; pulse pressure variation; stroke volume variation; global end-diastolic volume; ABDOMINAL COMPARTMENT SYNDROME; INTRATHORACIC BLOOD-VOLUME; END-DIASTOLIC VOLUME; CRITICALLY-ILL PATIENTS; CARDIAC-OUTPUT; INTERNATIONAL-CONFERENCE; RESPIRATORY CHANGES; PERFUSION-PRESSURE; SUPERIOR PARAMETER; LOADING CONDITIONS;
D O I
10.1097/CCM.0b013e3181959864
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Dynamic variables of fluid responsiveness such as pulse pressure variation (PPV) and stroke volume variation (SVV) have been shown to reliably predict the response to fluid administration in different patient populations. The influence of increased intra-abdominal pressure (IAP) on the predictive ability of these variables is currently under debate. Therefore, the present study was designed to evaluate whether PPV and SVV are suitable for predicting fluid responsiveness during elevated IAP. Design: Prospective controlled experimental study. Setting. Animal research laboratory. Subjects. 14 anesthetized and mechanically ventilated pigs. Interventions: Pigs were studied at different experimental stages: normovolemia at baseline conditions, after induction of pneumoperitoneum (PP) by increasing IAP up to 25 mm Hg, followed by releasing PIP and performing a fluid load with 1000 cc hydroxyl-ethyl starch 6%, and finally after inducing PP again. Cardiac output, stroke volume, central venous pressure, and pulmonary artery occlusion pressure were obtained by pulmonary artery thermodilution. Additionally, global end-diastolic volume (GEDV) was measured by transpulmonary thermodilution. PPV and SVV were monitored continuously by pulse contour analysis. Measurements and Main Results: PP induced significant changes in peak airway pressure, esophageal pressure, chest wall compliance, SVV, PPV, central venous pressure, and pulmonary artery occlusion pressure independent of loading conditions. As assessed by receiver operating characteristic curve analysis, PPV, SVV, and GEDV accurately predicted fluid responsiveness before IAP was increased (area under the curve: 0.90, 0.91 and 0.91). A PPV value of >= 11.5%, a SVV value of >= 9.5%, and a GEDV value of <= 963 mL accurately predicted an increase in stroke volume >= 15%. After increasing IAP, the ability of SVV to predict fluid responsiveness was abolished, whereas it was preserved with both PPV and GEDV, although the threshold value for PPV dramatically increased up to >= 20.5%. Conclusions. In this animal model PPV and GEDV proved to be sensitive and specific predictors of fluid responsiveness even during increased IAP. (Crit Care Med 2009; 37:650-658)
引用
收藏
页码:650 / 658
页数:9
相关论文
共 50 条
  • [41] Evaluation of stroke volume variation and pulse pressure variation as predictors of fluid responsiveness in patients undergoing protective one-lung ventilation
    Fu, Qiang
    Duan, Mingda
    Zhao, Feng
    Mi, Weidong
    DRUG DISCOVERIES AND THERAPEUTICS, 2015, 9 (04): : 296 - 302
  • [42] Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs
    Endo, Yusuke
    Tamura, Jun
    Ishizuka, Tomohito
    Itami, Takaharu
    Hanazono, Kiwamu
    Miyoshi, Kenjiro
    Sano, Tadashi
    Yamashita, Kazuto
    Muir, William W.
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2017, 79 (08): : 1437 - 1445
  • [43] Chronically Increased Intra-abdominal Pressure: Validating a Model
    Theodossis S. Papavramidis
    Thomai P. Lazou
    Angeliki Cheva
    Orestis J. Gamvros
    Obesity Surgery, 2010, 20 : 900 - 905
  • [44] Chronically Increased Intra-abdominal Pressure: Validating a Model
    Papavramidis, Theodossis S.
    Lazou, Thomai P.
    Cheva, Angeliki
    Gamvros, Orestis J.
    OBESITY SURGERY, 2010, 20 (07) : 900 - 905
  • [45] The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation
    Myatra, Sheila Nainan
    Prabu, Natesh R.
    Vasishtha, Jigeeshu
    Monnet, Xavier
    Kulkarni, Atul Prabhakar
    Teboul, Jean-Louis
    CRITICAL CARE MEDICINE, 2017, 45 (03) : 415 - 421
  • [46] Pulse pressure variation, stroke volume variation and dynamic arterial elastance
    Raphael Giraud
    Nils Siegenthaler
    Karim Bendjelid
    Critical Care, 15
  • [47] Influences of different vasopressors on stroke volume variation and pulse pressure variation
    Kong, Ran
    Liu, Yi
    Mi, Weidong
    Fu, Qiang
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (01) : 81 - 86
  • [48] Pulse pressure variation, stroke volume variation and dynamic arterial elastance
    Giraud, Raphael
    Siegenthaler, Nils
    Bendjelid, Karim
    CRITICAL CARE, 2011, 15 (02):
  • [49] Influences of different vasopressors on stroke volume variation and pulse pressure variation
    Ran Kong
    Yi Liu
    Weidong Mi
    Qiang Fu
    Journal of Clinical Monitoring and Computing, 2016, 30 : 81 - 86
  • [50] IVC pressure as an alternative reflection of intra-abdominal pressure using a porcine model
    Shah, S. S.
    Williams, J. B.
    Huh, J.
    Chark, D. W.
    ACTA CLINICA BELGICA, 2007, 62 : 284 - 284