Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model

被引:101
|
作者
Renner, Jochen [1 ]
Gruenewald, Matthias [1 ]
Quaden, Rene [2 ]
Hanss, Robert [1 ]
Meybohm, Patrick [1 ]
Steinfath, Markus [1 ]
Scholz, Jens [1 ]
Bein, Berthold [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesia & Intens Care Med, Campus Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Dept Cardiothorac & Vasc Surg, Campus Kiel, Germany
关键词
pneumoperitoneum; intra-abdominal pressure; intraabdominal hypertension; fluid responsiveness; preload; monitoring; pulse pressure variation; stroke volume variation; global end-diastolic volume; ABDOMINAL COMPARTMENT SYNDROME; INTRATHORACIC BLOOD-VOLUME; END-DIASTOLIC VOLUME; CRITICALLY-ILL PATIENTS; CARDIAC-OUTPUT; INTERNATIONAL-CONFERENCE; RESPIRATORY CHANGES; PERFUSION-PRESSURE; SUPERIOR PARAMETER; LOADING CONDITIONS;
D O I
10.1097/CCM.0b013e3181959864
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Dynamic variables of fluid responsiveness such as pulse pressure variation (PPV) and stroke volume variation (SVV) have been shown to reliably predict the response to fluid administration in different patient populations. The influence of increased intra-abdominal pressure (IAP) on the predictive ability of these variables is currently under debate. Therefore, the present study was designed to evaluate whether PPV and SVV are suitable for predicting fluid responsiveness during elevated IAP. Design: Prospective controlled experimental study. Setting. Animal research laboratory. Subjects. 14 anesthetized and mechanically ventilated pigs. Interventions: Pigs were studied at different experimental stages: normovolemia at baseline conditions, after induction of pneumoperitoneum (PP) by increasing IAP up to 25 mm Hg, followed by releasing PIP and performing a fluid load with 1000 cc hydroxyl-ethyl starch 6%, and finally after inducing PP again. Cardiac output, stroke volume, central venous pressure, and pulmonary artery occlusion pressure were obtained by pulmonary artery thermodilution. Additionally, global end-diastolic volume (GEDV) was measured by transpulmonary thermodilution. PPV and SVV were monitored continuously by pulse contour analysis. Measurements and Main Results: PP induced significant changes in peak airway pressure, esophageal pressure, chest wall compliance, SVV, PPV, central venous pressure, and pulmonary artery occlusion pressure independent of loading conditions. As assessed by receiver operating characteristic curve analysis, PPV, SVV, and GEDV accurately predicted fluid responsiveness before IAP was increased (area under the curve: 0.90, 0.91 and 0.91). A PPV value of >= 11.5%, a SVV value of >= 9.5%, and a GEDV value of <= 963 mL accurately predicted an increase in stroke volume >= 15%. After increasing IAP, the ability of SVV to predict fluid responsiveness was abolished, whereas it was preserved with both PPV and GEDV, although the threshold value for PPV dramatically increased up to >= 20.5%. Conclusions. In this animal model PPV and GEDV proved to be sensitive and specific predictors of fluid responsiveness even during increased IAP. (Crit Care Med 2009; 37:650-658)
引用
收藏
页码:650 / 658
页数:9
相关论文
共 50 条
  • [1] MODIFICATION OF STROKE VOLUME VARIATION WITH INCREASED INTRA-ABDOMINAL PRESSURE IN NORMOVOLEMIC PORCINE MODEL
    Deloya Tomas, E.
    Lomeli Teran, J. M.
    Martinez Mazariegos, J. J.
    Mondragon Labelle, T.
    Quintero Amaya, M.
    Leo Romero, S.
    Hernandez, D.
    Tendillo, F.
    Poblano, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S201 - S201
  • [2] Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study
    Didier Jacques
    Karim Bendjelid
    Serge Duperret
    Joëlle Colling
    Vincent Piriou
    Jean-Paul Viale
    Critical Care, 15
  • [3] Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study
    Jacques, Didier
    Bendjelid, Karim
    Duperret, Serge
    Colling, Joelle
    Piriou, Vincent
    Viale, Jean-Paul
    CRITICAL CARE, 2011, 15 (01):
  • [4] Pulse pressure variation and stroke volume variation predict fluid responsiveness in mechanically ventilated patients experiencing intra-abdominal hypertension
    Liu, Xiaomei
    Fu, Qiang
    Mi, Weidong
    Liu, Henian
    Zhang, Hong
    Wang, Peiji
    BIOSCIENCE TRENDS, 2013, 7 (02) : 101 - 108
  • [5] Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension
    F. Díaz
    B. Erranz
    A. Donoso
    T. Salomon
    Pablo Cruces
    BMC Anesthesiology, 15
  • [6] Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension
    Diaz, F.
    Erranz, B.
    Donoso, A.
    Salomon, T.
    Cruces, Pablo
    BMC ANESTHESIOLOGY, 2015, 15
  • [7] Accuracy of stroke volume variation as a predictor of volume responsiveness in patients with raised intra-abdominal pressure
    WO Bauer
    M Cecconi
    A Rhodes
    W Bernal
    J Wendon
    G Auzinger
    Critical Care, 15 (Suppl 1):
  • [8] Influence of intra-abdominal pressure on the specificity of pulse pressure variations to predict fluid responsiveness
    Royer, Patrick
    Bendjelid, Karim
    Valentino, Ruddy
    Resiere, Dabor
    Chabartier, Cyrille
    Mehdaoui, Hossein
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2015, 78 (05): : 994 - 999
  • [9] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [10] Stroke Volume Variation and Pulse Pressure Variation Are Not Useful for Predicting Fluid Responsiveness in Thoracic Surgery
    Jeong, Dae Myoung
    Ahn, Hyun Joo
    Park, Hyo Won
    Yang, Mikyung
    Kim, Jie Ae
    Park, Joohyun
    ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1158 - 1165