Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study

被引:76
|
作者
Jacques, Didier [1 ]
Bendjelid, Karim [2 ]
Duperret, Serge [3 ]
Colling, Joelle [3 ]
Piriou, Vincent [4 ]
Viale, Jean-Paul [5 ]
机构
[1] Ctr Hosp Lyon Sud, Dept Emergency & Med Intens Care, F-69495 Pierre Benite, France
[2] Univ Hosp Geneva, Dept Anesthesiol Pharmacol & Intens Care, Intens Care Serv, CH-1211 Geneva, Switzerland
[3] Hosp Civils Lyon, Dept Anesthesiol & Intens Care, Grp Hosp Nord, F-69317 Lyon 04, France
[4] Ctr Hosp Lyon Sud, Dept Anesthesiol & Intens Care, F-69495 Pierre Benite, France
[5] Univ Lyon 1, INSERM, EA ERI 4173 22, Physiol Lab, F-69008 Lyon, France
来源
CRITICAL CARE | 2011年 / 15卷 / 01期
关键词
ASSESSING FLUID RESPONSIVENESS; CRITICALLY-ILL PATIENTS; MECHANICALLY VENTILATED PATIENTS; ABDOMINAL COMPARTMENT SYNDROME; SEPSIS-INDUCED HYPOTENSION; LEFT-VENTRICULAR PRELOAD; LEG-RAISING MANEUVER; INTERNATIONAL-CONFERENCE; RESPIRATORY CHANGES; SEPTIC PATIENTS;
D O I
10.1186/cc9980
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The aim of this study was to evaluate dynamic indices of fluid responsiveness in a model of intra-abdominal hypertension. Methods: Nine mechanically-ventilated pigs underwent increased intra-abdominal pressure (IAP) by abdominal banding up to 30 mmHg and then fluid loading (FL) at this IAP. The same protocol was carried out in the same animals made hypovolemic by blood withdrawal. In both volemic conditions, dynamic indices of preload dependence were measured at baseline IAP, at 30 mmHg of IAP, and after FL. Dynamic indices involved respiratory variations in stroke volume (SVV), pulse pressure (PPV), and systolic pressure (SPV, %SPV and.down). Stroke volume (SV) was measured using an ultrasound transit-time flow probe placed around the aortic root. Pigs were considered to be fluid responders if their SV increased by 15% or more with FL. Indices of fluid responsiveness were compared with a Mann-Whitney U test. Then, receiver operating characteristic (ROC) curves were generated for these parameters, allowing determination of the cut-off values by using Youden's method. Results: Five animals before blood withdrawal and all animals after blood withdrawal were fluid responders. Before FL, SVV (78 +/- 19 vs 42 +/- 17%), PPV (64 +/- 18 vs 37 +/- 15%), SPV (24 +/- 5 vs 18 +/- 3 mmHg), % SPV (24 +/- 4 vs 17 +/- 3%) and.down (13 +/- 5 vs 6 +/- 4 mmHg) were higher in responders than in non-responders (P < 0.05). Areas under ROC curves were 0.93 (95% confidence interval: 0.80 to 1.06), 0.89 (0.70 to 1.07), 0.90 (0.74 to 1.05), 0.92 (0.78 to 1.06), and 0.86 (0.67 to 1.06), respectively. Threshold values discriminating responders and non-responders were 67% for SVV and 41% for PPV. Conclusions: In intra-abdominal hypertension, respiratory variations in stroke volume and arterial pressure remain indicative of fluid responsiveness, even if threshold values identifying responders and non-responders might be higher than during normal intra-abdominal pressure. Further studies are required in humans to determine these thresholds in intra-abdominal hypertension.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study
    Didier Jacques
    Karim Bendjelid
    Serge Duperret
    Joëlle Colling
    Vincent Piriou
    Jean-Paul Viale
    Critical Care, 15
  • [2] Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension
    F. Díaz
    B. Erranz
    A. Donoso
    T. Salomon
    Pablo Cruces
    BMC Anesthesiology, 15
  • [3] Influence of tidal volume on pulse pressure variation and stroke volume variation during experimental intra-abdominal hypertension
    Diaz, F.
    Erranz, B.
    Donoso, A.
    Salomon, T.
    Cruces, Pablo
    BMC ANESTHESIOLOGY, 2015, 15
  • [4] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [5] MODIFICATION OF STROKE VOLUME VARIATION WITH INCREASED INTRA-ABDOMINAL PRESSURE IN NORMOVOLEMIC PORCINE MODEL
    Deloya Tomas, E.
    Lomeli Teran, J. M.
    Martinez Mazariegos, J. J.
    Mondragon Labelle, T.
    Quintero Amaya, M.
    Leo Romero, S.
    Hernandez, D.
    Tendillo, F.
    Poblano, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S201 - S201
  • [6] Pulse pressure variation and stroke volume variation predict fluid responsiveness in mechanically ventilated patients experiencing intra-abdominal hypertension
    Liu, Xiaomei
    Fu, Qiang
    Mi, Weidong
    Liu, Henian
    Zhang, Hong
    Wang, Peiji
    BIOSCIENCE TRENDS, 2013, 7 (02) : 101 - 108
  • [7] Accuracy of stroke volume variation as a predictor of volume responsiveness in patients with raised intra-abdominal pressure
    WO Bauer
    M Cecconi
    A Rhodes
    W Bernal
    J Wendon
    G Auzinger
    Critical Care, 15 (Suppl 1):
  • [8] Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study
    Daudel, Fritz
    Tueller, David
    Kraehenbuehl, Stefanie
    Jakob, Stephan M.
    Takala, Jukka
    CRITICAL CARE, 2010, 14 (03):
  • [9] Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study
    Fritz Daudel
    David Tüller
    Stefanie Krähenbühl
    Stephan M Jakob
    Jukka Takala
    Critical Care, 14
  • [10] Respiratory variation in intra-abdominal pressure (△IAP)
    Sturini, E.
    Saporito, A.
    Sugrue, M.
    Parr, M.
    Bishop, G.
    ACTA CLINICA BELGICA, 2007, 62 : 265 - 265