Pulse pressure variation and stroke volume variation during increased intra-abdominal pressure: an experimental study

被引:76
|
作者
Jacques, Didier [1 ]
Bendjelid, Karim [2 ]
Duperret, Serge [3 ]
Colling, Joelle [3 ]
Piriou, Vincent [4 ]
Viale, Jean-Paul [5 ]
机构
[1] Ctr Hosp Lyon Sud, Dept Emergency & Med Intens Care, F-69495 Pierre Benite, France
[2] Univ Hosp Geneva, Dept Anesthesiol Pharmacol & Intens Care, Intens Care Serv, CH-1211 Geneva, Switzerland
[3] Hosp Civils Lyon, Dept Anesthesiol & Intens Care, Grp Hosp Nord, F-69317 Lyon 04, France
[4] Ctr Hosp Lyon Sud, Dept Anesthesiol & Intens Care, F-69495 Pierre Benite, France
[5] Univ Lyon 1, INSERM, EA ERI 4173 22, Physiol Lab, F-69008 Lyon, France
来源
CRITICAL CARE | 2011年 / 15卷 / 01期
关键词
ASSESSING FLUID RESPONSIVENESS; CRITICALLY-ILL PATIENTS; MECHANICALLY VENTILATED PATIENTS; ABDOMINAL COMPARTMENT SYNDROME; SEPSIS-INDUCED HYPOTENSION; LEFT-VENTRICULAR PRELOAD; LEG-RAISING MANEUVER; INTERNATIONAL-CONFERENCE; RESPIRATORY CHANGES; SEPTIC PATIENTS;
D O I
10.1186/cc9980
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The aim of this study was to evaluate dynamic indices of fluid responsiveness in a model of intra-abdominal hypertension. Methods: Nine mechanically-ventilated pigs underwent increased intra-abdominal pressure (IAP) by abdominal banding up to 30 mmHg and then fluid loading (FL) at this IAP. The same protocol was carried out in the same animals made hypovolemic by blood withdrawal. In both volemic conditions, dynamic indices of preload dependence were measured at baseline IAP, at 30 mmHg of IAP, and after FL. Dynamic indices involved respiratory variations in stroke volume (SVV), pulse pressure (PPV), and systolic pressure (SPV, %SPV and.down). Stroke volume (SV) was measured using an ultrasound transit-time flow probe placed around the aortic root. Pigs were considered to be fluid responders if their SV increased by 15% or more with FL. Indices of fluid responsiveness were compared with a Mann-Whitney U test. Then, receiver operating characteristic (ROC) curves were generated for these parameters, allowing determination of the cut-off values by using Youden's method. Results: Five animals before blood withdrawal and all animals after blood withdrawal were fluid responders. Before FL, SVV (78 +/- 19 vs 42 +/- 17%), PPV (64 +/- 18 vs 37 +/- 15%), SPV (24 +/- 5 vs 18 +/- 3 mmHg), % SPV (24 +/- 4 vs 17 +/- 3%) and.down (13 +/- 5 vs 6 +/- 4 mmHg) were higher in responders than in non-responders (P < 0.05). Areas under ROC curves were 0.93 (95% confidence interval: 0.80 to 1.06), 0.89 (0.70 to 1.07), 0.90 (0.74 to 1.05), 0.92 (0.78 to 1.06), and 0.86 (0.67 to 1.06), respectively. Threshold values discriminating responders and non-responders were 67% for SVV and 41% for PPV. Conclusions: In intra-abdominal hypertension, respiratory variations in stroke volume and arterial pressure remain indicative of fluid responsiveness, even if threshold values identifying responders and non-responders might be higher than during normal intra-abdominal pressure. Further studies are required in humans to determine these thresholds in intra-abdominal hypertension.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Increased intra-abdominal pressure in obesity
    Sugerman, HJ
    INTERNATIONAL JOURNAL OF OBESITY, 1998, 22 (11) : 1138 - 1138
  • [22] An Observational Study Comparing Intrathoracic Pressure Changes and Stroke Volume Variation with Abdominal Insufflation: Stroke Volume Variation vs. Esophageal Pressure
    Sadjadi, Sadaf
    Alzayat, Omar
    Subramanyam, Chaitra
    Fleming, Neal
    ANESTHESIA AND ANALGESIA, 2024, 139 (05): : 611 - 611
  • [23] Effect of Increased Intra-abdominal Pressure on Liver Histology and Hemodynamics: An Experimental Study
    Antoniou, Efstathios A.
    Kairi, Evi
    Margonis, Georgios A.
    Andreatos, Nikolaos
    Sasaki, Kazunari
    Damaskos, Christos
    Garmpis, Nikolaos
    Samaha, Mario
    Argyra, Eriphyli
    Polymeneas, George
    Weiss, Matthew J.
    Pawlik, Timothy M.
    Voros, Dionysios
    Kouraklis, Gregory
    IN VIVO, 2018, 32 (01): : 85 - 91
  • [24] Full-field in vivo experimental study of the strains of a breathing human abdominal wall with intra-abdominal pressure variation
    Szepietowska, Katarzyna
    Troka, Mateusz
    Lichodziejewska-Niemierko, Monika
    Chmielewski, Michal
    Lubowiecka, Izabela
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 147
  • [25] A comparative study of pulse pressure variation, stroke volume variation and central venous pressure in patients undergoing kidney transplantation
    Kim, Kyung Mi
    Kim, Gaab Soo
    Han, Minsoo
    SINGAPORE MEDICAL JOURNAL, 2022, 63 (12) : 731 - 739
  • [26] Intra-abdominal pressure - A critical review and an experimental study
    Lam, CR
    ARCHIVES OF SURGERY, 1939, 39 (06) : 1006 - 1015
  • [27] Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model
    Renner, J.
    Cavus, E.
    Meybohm, P.
    Gruenewald, M.
    Steinfath, M.
    Scholz, J.
    Boening, A.
    Bein, B.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2008, 52 (03) : 374 - 380
  • [28] Effects of continuous negative abdominal pressure on intrathoracic blood shift with and without increased intra-abdominal pressure: experimental study
    F Valenza
    M Guglielmi
    S Gatti
    N Bottino
    S Giacomini
    M Irace
    C Tedesco
    M Maffioletti
    P Maccagni
    L Gattinoni
    Critical Care, 7 (Suppl 2):
  • [29] The stroke volume variation correlates with the stroke volume and systolic pressure variation during haemorrhage and retransfusion
    Berkenstadt, H
    Friedman, Z
    Preisman, S
    Keidan, I
    Perel, A
    INTENSIVE CARE MEDICINE, 2001, 27 : S258 - S258
  • [30] Stroke volume variation and pulse pressure variation measured at pulmonary arterial level versus pulse pressure variation measured at systemic arterial level: an exploratory study
    Slabbaert, M.
    Vandenheuvel, M.
    Wouters, P.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 : 235 - 244