Analysis of Air-Side Economizers in Terms of Cooling-Energy Performance in a Data Center Considering Exhaust Air Recirculation

被引:8
|
作者
Park, Seonghyun [1 ]
Seo, Janghoo [2 ]
机构
[1] Kookmin Univ, Grad Sch, Dept Architecture, 77 Jeongneung Ro, Seoul 02707, South Korea
[2] Kookmin Univ, Sch Architecture, 77 Jeongneung Ro, Seoul 02707, South Korea
基金
新加坡国家研究基金会;
关键词
data center; air-side economizer; energy simulation; cooling system; recirculation;
D O I
10.3390/en11020444
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Demand is soaring for data centers with advanced data-processing capabilities. In data centers with high-temperature information technology (IT) equipment, enormous cooling systems are operated year-round. To date, studies have aimed to improve the cooling efficiency of server-room units, but cooling-energy-consumption analysis considering the recirculation of exhaust air (EA) has not been researched to a sufficient degree. This study analyzed the cooling-energy saving effects considering the EA-recirculation and supply-air (SA)-temperature conditions when direct and indirect air-side economizers were applied to a data center in Korea. Thirteen case studies were conducted. The results showed that when the EA-recirculation ratio in the direct air-side economizer was 15%, its annual cooling-energy consumption increased by approximately 6.1% compared to the case with no recirculation. The indirect air-side economizer also exhibited an approximately 9% increase in cooling-energy consumption. On the other hand, when the SA temperature changed to 22 degrees C, the annual cooling-energy consumption of the direct and indirect air-side economizers decreased by approximately 67% and 55%, respectively, compared to a central chilled-water system. This indicates the importance of developing measures to prevent EA recirculation and of securing a wind path for the improvement of air-conditioning efficiency in data centers at the design stage.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Energy saving potential of various air-side economizers in a modular data center
    Ham, Sang-Woo
    Kim, Min-Hwi
    Choi, Byung-Nam
    Jeong, Jae-Weon
    [J]. APPLIED ENERGY, 2015, 138 : 258 - 275
  • [2] Applicability assessment and climate zoning of using air-side economizers for data center cooling in China
    Jiang, Hang
    Li, Zuoyang
    Bai, Xuelian
    [J]. ENERGY AND BUILDINGS, 2024, 320
  • [3] Potential of air-side economizers for data center cooling: A case study for key Australian cities
    Siriwardana, Jayantha
    Jayasekara, Saliya
    Halgamuge, Saman K.
    [J]. APPLIED ENERGY, 2013, 104 : 207 - 219
  • [4] Simultaneous use of air-side and water-side economizers with the air source heat pump in a data center for cooling and heating production
    Deymi-Dashtebayaz, Mandi
    Namanlo, Sajjad Valipour
    Arabkoohsar, Ahmad
    [J]. APPLIED THERMAL ENGINEERING, 2019, 161
  • [5] Optimum supply air temperature ranges of various air-side economizers in a modular data center
    Ham, Sang-Woo
    Park, Jun-Seok
    Jeong, Jae-Weon
    [J]. APPLIED THERMAL ENGINEERING, 2015, 77 : 163 - 179
  • [6] Energy analysis on VAV system with different air-side economizers in China
    Yao, Ye
    Wang, Li
    [J]. ENERGY AND BUILDINGS, 2010, 42 (08) : 1220 - 1230
  • [7] ENERGY EFFICIENT DATA CENTERS USING EVAPORATIVE COOLING AND AIR SIDE ECONOMIZERS
    Iyengar, Madhusudan
    Schmidt, Roger
    [J]. PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 623 - 627
  • [8] Factor Analysis of Power-saving Effects in Air-side Economizers for Data Centers
    Tate, Ryuhei
    Kaneko, Shinichiro
    Mino, Yosuke
    Yanagi, Masahide
    [J]. 2015 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2015,
  • [9] Energy Efficiency Analysis of Data Center Based on All-Inverter Coupled Air-Side Free Cooling Technology
    Ai, Chuanxian
    Chen, Yinghu
    Zhang, Liang
    [J]. 2023 5TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES, 2023, : 61 - 69
  • [10] Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones
    Lee, Kuei-Peng
    Chen, Hsiang-Lun
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 103 - 112