Energy saving potential of various air-side economizers in a modular data center

被引:99
|
作者
Ham, Sang-Woo [1 ]
Kim, Min-Hwi [1 ]
Choi, Byung-Nam [2 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Div Architectural Engn, Seoul 133791, South Korea
[2] SAMHWA Air Conditioning Engn, Seoul 405818, South Korea
基金
新加坡国家研究基金会;
关键词
Modular data center; Cooling system; Air-side economizer; Evaporative cooling; Energy savings; SYSTEMS;
D O I
10.1016/j.apenergy.2014.10.066
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With the recent development of the IT technology, the demand for data centers has significantly increased, and modular data centers have attracted considerable attention because of their excellent stability, scalability, and economic feasibility. This research quantitatively analyzed the applicability of various air-side economizers and their energy-saving potential in modular data centers. A detailed cooling load estimation process was established for modular data centers, and annual cooling energy simulations were carried out using various air-side economizers. The various air-side economizers yielded cooling coil load savings of 76-99% in comparison to conventional cooling systems in data centers, and the total cooling energy savings of the economizers ranged from 47.5% to 67.2%. Indirect air-side economizers with high-effectiveness heat exchangers were found to yield significant energy saving (63.6%) and have simple system configurations. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:258 / 275
页数:18
相关论文
共 50 条
  • [1] Optimum supply air temperature ranges of various air-side economizers in a modular data center
    Ham, Sang-Woo
    Park, Jun-Seok
    Jeong, Jae-Weon
    [J]. APPLIED THERMAL ENGINEERING, 2015, 77 : 163 - 179
  • [2] Potential of air-side economizers for data center cooling: A case study for key Australian cities
    Siriwardana, Jayantha
    Jayasekara, Saliya
    Halgamuge, Saman K.
    [J]. APPLIED ENERGY, 2013, 104 : 207 - 219
  • [3] Factor Analysis of Power-saving Effects in Air-side Economizers for Data Centers
    Tate, Ryuhei
    Kaneko, Shinichiro
    Mino, Yosuke
    Yanagi, Masahide
    [J]. 2015 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2015,
  • [4] Analysis of Air-Side Economizers in Terms of Cooling-Energy Performance in a Data Center Considering Exhaust Air Recirculation
    Park, Seonghyun
    Seo, Janghoo
    [J]. ENERGIES, 2018, 11 (02)
  • [5] The Energy-Saving Potential of Air-Side Economisers in Modular Data Centres: Analysis of Opportunities and Risks in Different Climates
    Badiei, Ali
    Jadowski, Eric
    Sadati, Saba
    Beizaee, Arash
    Li, Jing
    Khajenoori, Leila
    Nasriani, Hamid Reza
    Li, Guiqiang
    Xiao, Xin
    [J]. SUSTAINABILITY, 2023, 15 (14)
  • [6] Applicability assessment and climate zoning of using air-side economizers for data center cooling in China
    Jiang, Hang
    Li, Zuoyang
    Bai, Xuelian
    [J]. ENERGY AND BUILDINGS, 2024, 320
  • [7] Energy analysis on VAV system with different air-side economizers in China
    Yao, Ye
    Wang, Li
    [J]. ENERGY AND BUILDINGS, 2010, 42 (08) : 1220 - 1230
  • [8] Simultaneous use of air-side and water-side economizers with the air source heat pump in a data center for cooling and heating production
    Deymi-Dashtebayaz, Mandi
    Namanlo, Sajjad Valipour
    Arabkoohsar, Ahmad
    [J]. APPLIED THERMAL ENGINEERING, 2019, 161
  • [9] Analysis of energy saving potential of air-side free cooling for data centers in worldwide climate zones
    Lee, Kuei-Peng
    Chen, Hsiang-Lun
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 103 - 112
  • [10] Energy, environmental and economical saving potential of data centers with various economizers across Australia
    Khalaj, Ali Habibi
    Scherer, Thomas
    Halgamuge, Saman K.
    [J]. APPLIED ENERGY, 2016, 183 : 1528 - 1549