Analysis of Air-Side Economizers in Terms of Cooling-Energy Performance in a Data Center Considering Exhaust Air Recirculation

被引:8
|
作者
Park, Seonghyun [1 ]
Seo, Janghoo [2 ]
机构
[1] Kookmin Univ, Grad Sch, Dept Architecture, 77 Jeongneung Ro, Seoul 02707, South Korea
[2] Kookmin Univ, Sch Architecture, 77 Jeongneung Ro, Seoul 02707, South Korea
基金
新加坡国家研究基金会;
关键词
data center; air-side economizer; energy simulation; cooling system; recirculation;
D O I
10.3390/en11020444
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Demand is soaring for data centers with advanced data-processing capabilities. In data centers with high-temperature information technology (IT) equipment, enormous cooling systems are operated year-round. To date, studies have aimed to improve the cooling efficiency of server-room units, but cooling-energy-consumption analysis considering the recirculation of exhaust air (EA) has not been researched to a sufficient degree. This study analyzed the cooling-energy saving effects considering the EA-recirculation and supply-air (SA)-temperature conditions when direct and indirect air-side economizers were applied to a data center in Korea. Thirteen case studies were conducted. The results showed that when the EA-recirculation ratio in the direct air-side economizer was 15%, its annual cooling-energy consumption increased by approximately 6.1% compared to the case with no recirculation. The indirect air-side economizer also exhibited an approximately 9% increase in cooling-energy consumption. On the other hand, when the SA temperature changed to 22 degrees C, the annual cooling-energy consumption of the direct and indirect air-side economizers decreased by approximately 67% and 55%, respectively, compared to a central chilled-water system. This indicates the importance of developing measures to prevent EA recirculation and of securing a wind path for the improvement of air-conditioning efficiency in data centers at the design stage.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Numerical Analysis of Exhaust Air Energy Extractor for Cooling Tower Applications
    Singh, Enderaaj
    Roy, Sukanta
    San, Yam Ke
    [J]. 2ND INTERNATIONAL CONFERENCE ON MATERIALS TECHNOLOGY AND ENERGY, 2020, 943
  • [22] Total Cost of Ownership Comparison of Air Economizers to Other Energy Saving Techniques in Data Center Applications
    Spangler, Ron
    Jeffers, Gregory
    [J]. ASHRAE TRANSACTIONS 2010, VOL 116, PT 2, 2010, 116 : 82 - +
  • [23] The Energy-Saving Potential of Air-Side Economisers in Modular Data Centres: Analysis of Opportunities and Risks in Different Climates
    Badiei, Ali
    Jadowski, Eric
    Sadati, Saba
    Beizaee, Arash
    Li, Jing
    Khajenoori, Leila
    Nasriani, Hamid Reza
    Li, Guiqiang
    Xiao, Xin
    [J]. SUSTAINABILITY, 2023, 15 (14)
  • [24] Air-side data interpretation and performance analysis for heat exchangers with simultaneous heat and mass transfer: Wet and frosted surfaces
    Xia, YP
    Jacobi, AM
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (25-26) : 5089 - 5102
  • [25] Energy performance evaluation in a data center with water-side free cooling
    Mi, Ranran
    Bai, Xuelian
    Xu, Xin
    Ren, Fei
    [J]. ENERGY AND BUILDINGS, 2023, 295
  • [26] Air-Side Performance Analysis by Geometric Parameters of Hybrid-Wave-Slit Fin Using CFD
    Park, Seong Su
    Kang, Hyeong Uk
    Ahn, Joon
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2024, 48 (06) : 361 - 369
  • [27] A Simple Air-Side Data Analysis Method for Partially Wet Flat-Tube Heat Exchangers
    Park, Young-Gil
    Jacobi, Anthony M.
    [J]. HEAT TRANSFER ENGINEERING, 2011, 32 (02) : 133 - 140
  • [28] Energy advantage of cold energy recovery system using water- and air-side free cooling technologies in semiconductor fabrication plant in summer
    Kwon, Taek-Don
    Jeong, Jae-Weon
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 69
  • [29] Air-Side Heat Transfer Performance of Louver Fin and Multitube Heat Exchanger for Direct Methanol Fuel Cell Cooling Application
    Kang, Hie Chan
    Cho, Hyejung
    Kim, Jin Ho
    Jacobi, Anthony M.
    [J]. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2014, 11 (04):
  • [30] Numerical analysis of layout of air conditioning in data center considering seasonal factors
    Fang, Lele
    Xu, Qingshan
    Yin, Tang
    Fang, Jicheng
    Shi, Yusong
    [J]. ENERGY REPORTS, 2022, 8 : 1365 - 1371