Production of epithermal neutron beams for BNCT

被引:10
|
作者
Bisceglie, E
Colangelo, P
Colonna, N
Paticchio, V
Santorelli, P
Variale, V
机构
[1] Ist Nazl Fis Nucl, Sezione Bari, I-70126 Bari, Italy
[2] Univ Naples Federico II, Dipartimento Sci Fis, I-80125 Naples, Italy
[3] Ist Nazl Fis Nucl, I-80125 Naples, Italy
关键词
D O I
10.1016/S0168-9002(01)01406-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The use of boron neutron capture therapy (BNCT) for the treatment of deep-seated tumors requires neutron beams of suitable energy and intensity. Simulations indicate the optimal energy to reside in the epithermal region, in particular between 1 and 10 keV. Therapeutic neutron beams with high spectral purity in this energy range could be produced with accelerator-based neutron sources through a suitable neutron-producing reaction. Herein, we report on different solutions that have been investigated as possible sources of epithermal neutron beams for BNCT. The potential use of such sources for a hospital-based therapeutic facility is discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 50 条
  • [41] Performance verification of an epithermal neutron flux monitor using accelerator-based BNCT neutron sources
    Guan, X.
    Murata, I.
    Wang, T.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [42] On the 252Cf primary and secondary gamma rays and epithermal neutron flux for BNCT
    Ghassoun, J.
    Merzouki, A.
    El Morabiti, A.
    Jehouani, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 231 - 233
  • [43] Design of an epithermal column for BNCT based on D-D fusion neutron facility
    Durisi, E.
    Zanini, A.
    Manfredotti, C.
    Palamara, F.
    Sarotto, M.
    Visca, L.
    Nastasi, U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (02): : 363 - 369
  • [44] Design of epithermal neutron beam for clinical BNCT treatment at Slovenian TRIGA research reactor
    Maucec, M
    RRFM'99: 3RD INTERNATIONAL TOPICAL MEETING ON RESEARCH REACTOR FUEL MANAGEMENT, 1999, : 34 - 38
  • [45] Neutron spectra measurement and comparison of the HFR and THOR BNCT beams
    Liu, Yuan-Hao
    Nievaart, Sander
    Tsai, Pi-En
    Liu, Hong-Ming
    Moss, Ray
    Jiang, Shiang-Huei
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S137 - S140
  • [46] Spectrum shaping of accelerator-based neutron beams for BNCT
    Montagnini, B
    Cerullo, N
    Esposito, J
    Giusti, V
    Mattioda, F
    Varone, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 90 - 98
  • [47] Epithermal neutron beams for clinical studies of boron neutron capture therapy: A dosimetric comparison of seven beams
    Binns, PJ
    Riley, KJ
    Harling, OK
    RADIATION RESEARCH, 2005, 164 (02) : 212 - 220
  • [48] Optimized accelerator based epithermal neutron beams for boron neutron capture therapy
    Kudchadker, RJ
    MEDICAL PHYSICS, 1997, 24 (07) : 1182 - 1182
  • [49] Characterisation of the TAPIRO BNCT epithermal facility
    Burn, KW
    Colli, V
    Curzio, G
    d'Errico, F
    Gambarini, G
    Rosi, G
    Scolari, L
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 645 - 649
  • [50] The dose comparison between the THOR and HFR epithermal neutron beams
    Lin, Yi-Chun
    Roca, Antoaneta
    Liu, Yuan-Hao
    Tsai, Pi-En
    Nievaart, Sander
    Liu, Hong-Ming
    Moss, Ray
    Chou, Wen-Tsae
    Jiang, Shiang-Huei
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1422 - 1426